Rexroth EcoDrive Cs
Instructions for Use
5-7
DOK-ECODR3-DKC*CS*UL**-IB01-EN-P
Technical Data of the Terminal Connector
schnittstellen_X3.fh7
TX
RX
S20
2
1
ON
X4
X5
X6
9
8
7 6 5 4
3
2
1
9
8
7 6 5 4
3
2
1
ADDRESS
NODE
0
0
Rexroth
ECODRIVE Cs
S1
H1
S2
S3
LINE ERROR
X20
X21
X4
X5_3
X5_2
X5_1
INPUTíF200V
-240V
X3
X2
X1
X6
U
V
W
Ground
Fig. 5-13:
Terminal connector X3
Type
Number of poles
Type of design
spring tension
4
socket on connector
Fig. 5-14:
Design
Max. connectable cross section
[mm²]
Max. cross section in AWG
gauge No.:
0,75 - 2
18 - 14
Fig. 5-15:
Connection cross section
For connecting drive controller and motor please use the appropriate
Rexroth motor power cables.
Cable length:
The maximum cable length is
40 m
with:
•
ready-made Rexroth cable
•
ambient temperature of
≤
40 °C according to EN 60204
•
maximum switching frequency of 8 kHz
WARNING
No warranty!
If cables manufactured by a company other than Bosch
Rexroth resp. cables longer than 40 m are used, the
Bosch Rexroth warranty for the entire drive system
becomes invalid.
Use ready-made Rexroth cables!
Graphic Representation
Design
Connection Cross Section
Motor Cables
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com