30
/40
BODAS displays
| Installation
Bosch Rexroth AG, RE 95289-01-B/2021-10-12
ø10
ø5.6
0.5 × 45°
1 × 45°
5.4
65
10
M8
60°
R25
A
A
Section A–A
Rear view
Fig. 14: Mounting bracket recommendations
▶ The tightening torque for the 3 threaded screws M5 is 3±0.3 Nm.
▶ Suitable measures (e.g. adhesive) should be taken to prevent the M5 threaded
screws from loosening.
7.3.4 Information on wiring and circuitry
• Always connect the GND and CarGND terminals at the display DI4 to ensure that
the product characteristics are complied with.
• In order to improve EMC compatibility, especially regarding emissions,
individual insulation of all cables with ferrite rings may be required.
• The BODAS display and the cameras must be powered from the same network.
Powering the camera from a port on the display is recommended.
• Wires to cameras must be shielded. The shielding must be connected to
the electronics on one side or to the device or vehicle ground via a low resistance
connection.
• Lines to the electronics must not be routed close to other power-conducting lines
in the device or vehicle.
• The wiring harness should be fixated mechanically in the area in which the
BODAS display DI4 is installed (distance < 150 mm). The wiring harness must
be secured so that in-phase excitation with the display occurs (e.g. at the
display bolting point).
• If possible, lines should be routed in the vehicle interior. If the lines are routed
outside of the vehicle, their secure mounting is to be ensured.
• Lines must not be kinked or twisted, must not rub against edges and must not be
routed through sharp-edged ducts without protection.
• Lines are to be routed with sufficient distance from hot or moving vehicle parts.