Installation 45/64
RE 92750-01-B/06.2018, A10VG, Series 10,
Bosch Rexroth AG
7.4.11 Electrically connecting the axial piston unit
NOTICE
Short circuit due to penetrating hydraulic fluid!
Fluid can penetrate the product and cause a short circuit!
▶
Do not install axial piston units with electric components (e.g. electric controls,
sensors) in a reservoir below the fluid level (inside-reservoir installation).
The machine/system manufacturer is responsible for the layout of the electric
control.
Electrically controlled axial piston units must be connected in accordance with the
electrical circuit diagram for the machine/system.
For axial piston units with electrical control and/or mounted sensors, observe the
information in data sheet 92750, e.g.:
• Permissible voltage range
• Permissible current
• Correct pin assignment
• Recommended electrical control units
Exact details on the connector, type of protection and matching mating connector
can also be found in data sheet 92750. The mating connector is not included in the
scope of delivery.
1.
Switch off the power supply to the relevant system component.
2.
Electrically connect the axial piston unit (12 or 24 V). Before connecting, check
whether the connector protective covers (3) are off (see Fig. 11 “Removing
transport protection” on page 38), and the connector and all seals are intact.
If necessary, you can change the position of the connector by turning the solenoid
body. This is not dependent on the connector version.
CAUTIOn! Hot surfaces on the solenoid!
Risk of burns!
▶
Allow the solenoid to cool down sufficiently before touching it.
▶
Wear heat-resistant, protective clothing, e.g., gloves.
To do this, proceed as follows:
1.
Loosen the mounting nut (1) of the solenoid. To do this, turn the mounting
nut (1) one turn counter-clockwise.
2.
Turn the solenoid body (2) to the desired position.
3.
Re-tighten the mounting nut. Tightening torque of the mounting nut: 5+1 Nm.
Changing connector
position
1
2