40/64 Installation
Bosch Rexroth AG
, Series 10 A10VG, RE 92750-01-B/06.2018
7.4.10 Hydraulically connecting the axial piston unit
NOTICE
Insufficient suction pressure!
Generally, a min. permissible suction pressure at port “S” is specified for axial
piston pumps in all installation positions. If the pressure at port S drops below the
specified values, damage may occur which may lead to the axial piston pump being
damaged beyond repair!
▶
Make sure the necessary suction pressure is maintained. This is influenced by:
– The piping (e.g., suction cross-section, pipe diameter, length of suction line)
– The position of the reservoir
– The viscosity of the hydraulic fluid
– A filter element or check valve in the suction line (regularly check the filter
element's level of contamination)
The machine/system manufacturer is responsible for sizing the lines. Connect the
axial piston unit to the rest of the hydraulic system in accordance with the hydraulic
circuit diagram of the machine/system manufacturer.
The ports and fastening threads are designed for the maximum permissible
pressures
p
max
, see Table 10 “Ports A10VG series 10” on page 43. The machine/
system manufacturer should make sure the connecting elements and lines
correspond to the specified application conditions (pressure, flow, hydraulic fluid,
temperature) with the necessary safety factors.
Connect only hydraulic lines that are appropriate for the axial piston unit port
(pressure level, size, system of units).
Observe the following information when routing the suction, pressure and drain
lines.
• Lines and hoses should be installed without pre-charge pressure so no further
mechanical forces are applied during operation that will reduce the service life of
the axial piston unit and, possibly, the entire machine/system.
• Use suitable seals as sealing material.
• Suction line (pipe or hose)
– The suction line should be as short and straight as possible.
– Measure the cross-section of the suction line so the pressure at the suction port
does not drop below the min. permissible pressure. Make sure the max. suction
pressure is not exceeded (e.g., when prefilling).
– Make sure the connections and connecting elements are airtight.
– The hose must be pressure-resistant, including to external air pressure.
• Pressure line
– For the pressure lines, use only pipes, hoses and connecting elements rated for
the working pressure range specified in data sheet 92750 (see Table 10).
notices on routing lines