38/60 Installation
Bosch Rexroth AG
, A10VO, A10VSO Series 31, RE 92701-01-B/04.2018
L
L
1
B
S
X
Fig. 13: Port overview A10VO Series 31, SAE flange ports at rear
L
1
S
B
L
X
Fig. 14: Port overview A10VO/A10VSO Series 31, SAE flange ports at top, opposite at bottom
Table 11: Ports A10VO/A10VSO Series 31
Ports
1)
p
max
[bar]
2)
State
3)
B
Working port (standard pressure series)
350
O
S
Suction port (standard pressure series)
10
O
l
Drain port
2
O
4)
l
1
Drain port
2
X
4)
X
Pilot pressure
350
O
X
Pilot pressure with DG-control
350
O
1)
The measuring system and thread size can be found in the installation drawing.
2)
Momentary pressure peaks may occur depending on the application. Keep this in mind when
selecting measuring devices and fittings.
3)
O = Must be connected (plugged when delivered)
X = Plugged (in normal operation)
4)
Depending on the installation position,
l
or
l
1
must be connected (see section 7.3 “Installation
Port overview