Bosch Security Systems | 2011-02
Praesideo 3.5
| Installation and User Instructions | 9 | System Configuration
en
| 394
47.3.19 Local BGM source
The
Local BGM source
action is used to step through all
available BGM sources in the assigned zone (groups)
including an inserted ‘BGM off’ position. See figure
47.26 for an overview of the
Action programming
page for
a
Local BGM source
key.
•
Action type
- Sets the action type.
•
Available outputs
- Shows the available zones and
zone groups. Use the dropdown list to choose the
type of outputs that are shown.
•
Add/Remove buttons
- Using the
>
and
<
buttons, selected outputs can be added to or
removed from
Assigned outputs
.
•
Assigned outputs
- Shows the outputs that have
been assigned to the key.
47.3.20 Local BGM volume control
The
Local BGM volume control
action is used to control
the volume of the BGM in the assigned zone (groups).
It can be changed in steps of 3 dB between -96 dB and
0 dB. See figure 47.26 for an overview of the
Action
programming
page for a
Local BGM volume control
key.
•
Action type
- Sets the action type.
•
Volume control
- Sets the type of volume control.
To increase the volume, select
Volume up
. To decrease
the volume, select
Volume down
.
•
Available outputs
- Shows the available zones and
zone groups. Use the dropdown list to choose the
type of outputs that are shown.
•
Add/Remove buttons
- Using the
>
and
<
buttons, selected outputs can be added to or
removed from
Assigned outputs
.
•
Assigned outputs
- Shows the outputs that have
been assigned to the key.
Note
This action can also be assigned to control
inputs.
figure 47.26: Local BGM source key
Note
This action can also be assigned to control
inputs.
figure 47.27: Local BGM volume control key
Содержание Praesideo 3.5
Страница 1: ...Praesideo 3 5 Installation and User Instructions Digital Public Address and Emergency Sound System en ...
Страница 131: ...Bosch Security Systems 2011 02 Praesideo 3 5 Installation and User Instructions 4 Amplifiers en 131 Part 4 Amplifiers ...
Страница 201: ...Bosch Security Systems 2011 02 2011 02 Installation and User Instructions 5 Call Stations en 201 Part 5 Call Stations ...
Страница 309: ...Bosch Security Systems 2011 02 Praesideo 3 5 Installation and User Instructions 8 Software en 309 Part 8 Software ...
Страница 411: ...Bosch Security Systems 2011 02 Praesideo 3 5 Installation and User Instructions 10 Events en 411 Part 10 Events ...
Страница 487: ...Bosch Security Systems 2011 02 Praesideo 3 5 Installation and User Instructions 12 Appendices en 487 Part 12 Appendices ...
Страница 497: ......
Страница 498: ... Bosch Security Systems B V Data subject to change without notice 2011 02 ...