Bosch Security Systems | 2011-02
Praesideo 3.5
| Installation and User Instructions | 4 | Amplifiers
en
| 151
8.8 Technical
data
8.8.1
Physical characteristics
8.8.2
Climate conditions
8.8.3
EMC and Safety
8.8.4
Mean time between failure
8.8.5
System bus
8.8.6
Power supply
8.8.7
Back-up power
Dimensions (H x W x D):
88 x 483 x 400 mm (19" installation, with brackets,
360 mm depth behind the brackets, 40 mm in front of
the brackets)
92 x 440 x 400 mm (table-top, with feet)
Weight:
PRS-1P500
12.6 kg
PRS-2P250
13.6 kg
PRS-4P125
16.1 kg
LBB4428/00
14.5 kg
Temperature:
-5 to +55 °C (operating)
-20 to +70 °C (non-operating)
Relative humidity:
15 to 90%, non-condensing (operating)
5 to 95%, non-condensing (non-operating)
Air pressure:
600 to 1100 hPa
Electromagnetic compatibility:
EN55103-1/FCC-47 part 15B
EN55103-2
EN50121-4
EN50130-4
Electrical safety:
IEC60065 (CB-scheme)
EN60065
Approvals:
CE marking
EN60849, EN54-16 and ISO7240-16
IEC60945
MTBF:
32,000 hours at +55 °C
(The MTBF doubles for every 10 °C decrease in
temperature.)
Connector (rear side):
Female proprietary connector
Preferred cable:
LBB4416/xx
Maximum cable length:
50 m (per system bus connector)
Data signal interface:
Plastic optical fiber
Network power consumption:
0 W
Connector (rear side):
IEC male power inlet with fuse holder
Preferred cable:
Mains cord meeting CE standard
Voltage selector:
115 V(AC) / 230 V(AC) for PRS-xPxxx
Nominal input voltage range:
PRS-xPxxx
115 V (typical): 100 - 120 V(AC) at 50 - 60 Hz
230 V (typical): 220 - 240 V(AC) at 50 - 60 Hz
LBB4428/00
100 - 240 V(AC) at 50 - 60 Hz
Input voltage limits:
PRS-xPxxx
115 V (typical): 90 - 132 V(AC) at 50 - 60 Hz
230 V (typical): 198 - 264 V(AC) at 50 - 60 Hz
LBB4428/00
90 - 264 V(AC) at 50 - 60 Hz
On/Off switch:
Located at the rear
Connector (rear side):
2 pole for removable screw connector
Input voltage:
48 V(DC)
Input voltage range:
43.5 to 56 V(DC)
Input voltage range for rated output power:
53 to 56V (DC)
Maximum current:
12 A
Содержание Praesideo 3.5
Страница 1: ...Praesideo 3 5 Installation and User Instructions Digital Public Address and Emergency Sound System en ...
Страница 131: ...Bosch Security Systems 2011 02 Praesideo 3 5 Installation and User Instructions 4 Amplifiers en 131 Part 4 Amplifiers ...
Страница 201: ...Bosch Security Systems 2011 02 2011 02 Installation and User Instructions 5 Call Stations en 201 Part 5 Call Stations ...
Страница 309: ...Bosch Security Systems 2011 02 Praesideo 3 5 Installation and User Instructions 8 Software en 309 Part 8 Software ...
Страница 411: ...Bosch Security Systems 2011 02 Praesideo 3 5 Installation and User Instructions 10 Events en 411 Part 10 Events ...
Страница 487: ...Bosch Security Systems 2011 02 Praesideo 3 5 Installation and User Instructions 12 Appendices en 487 Part 12 Appendices ...
Страница 497: ......
Страница 498: ... Bosch Security Systems B V Data subject to change without notice 2011 02 ...