© 2014 Bosch Security Systems, Inc.
F.01U.282.674 | 05 | 2014.10 |
1
en Installation Guide
CAUTION!
Ensure that the pole mount installation is secure and stable. Failure to do so may result
in personal injury, or damage the device.
Figure 3.1: Terminal strip overview and wiring example.
Figure 1.2 Transmitter/receiver dimensions
Figure 2.1: Fastening the mounting plate and removing the cover.
Callout - Description
1 - Cover
7 - Optical Alignment scope
2 - Wiring terminals
8 - Mounting plate
3 - LED indicators
9 - Wire entry
4 - Tamper switch
10 - Cover securing screws
5 - Vertical adjustment screw
11 - Device securing screws
6 - Twin lens
Figure 1.1 Transmitter and receiver overview
The ISC-FPB1-W30DS, ISC-FPB1-W60DS, and ISC-FPB1-W90DS are
dual-beam photoelectric detectors designed for indoor and outdoor
applications. Consisting of a separate transmitter and receiver, they
are designed to activate an alarm when an intruder passes within the
direct line of sight between the transmitter and receiver.
1 Overview
2 Installation
2.1 Wall mount installation
1. Remove the cover and the mounting plate. Refer to Figure 2.1.
2. Fasten the mounting plate by drilling holes, and then installing the screws, and fastening the
mounting plate onto the wall.
1
.
2
.
3
.
4
.
3. Route the wire through by inserting the wire between the foam sealing block. Verify the foam
seals against the wires to prevent insects from entering the device. Refer to Figure 2.2.
4. Attach the sensor to the mounting plate, and then fasten the screws.
Figure 2.2: Inserting the wire and fastening the mounting plate to the sensor.
5. Close the sensor by fastening the device fixing screws, and then close the cover.
2.2 Pole mount installation
1. Route the wire through the wire hole of the pole.
2. Attach the bracket to the pole with the pole mount clamp.
1
.
2
.
Figure 2.3: Routing the wire through the pole and attaching the bracket to the pole holder.
3 Wiring
3.1 Terminal strip overview
1
2
3
4
5
6
11
11
11
7
4
2
9
9
7
8
9
10
1.1 Coverage range:
Model
Outdoor
Indoor
ISC-FPB1-W30DS
30 m/100 ft
60 m/200 ft
ISC-FPB1-W60DS
60 m/200 ft
120 m/400 ft
ISC-FPB1-W90DS
90 m/300 ft
180 m/600 ft
1.2 Accessories:
Accessories
BH12T
10.5V-28VDC Heater
MP1
Metal pole, 1 m (3 ft)
MP2
Metal pole, 1.2 m (4 ft)
MP3
L-curved metal pole
Callout - Description
1 - Knockout
4 - Pole mount bracket
2 - Center of the upper beam
5 - Pole mount clamp
3 - Center of the lower beam
6 - Pole diameter between 38-42.7 mm/1.49-1.68 in