6
To adjust the minimum flame for N.G. replace the control knob
onto the spindle, light the gas and turn the control knob to the
small flame position. Screw the adjustment screw anti-
clockwise to estabilish a minimum stable flame position. The
flame should remain alight and not burn back to the injector
when the valve is turned quickly from ‘Full On’ to the “Minimum
flame” position and back a few times. To adjust the minimum
flame position for ULPG the screw must be fully tightened down
clockwise.
If the by-pass screw cannot be accessed, disassemble the
grease drip tray, which is fixed to the rest of the hob using a
clip and screw mounting system. The following steps must be
taken to remove it:
1.
Remove all pan supports, burner caps, diffusers and control
knobs.
2.
Loosen the screws on the burners.
3.
To assemble the grease splash tray again, proceed in the
reverse order to removal.
It is important that
all
the seals are refitted to form a seal
.
Never remove the tap spindle. In the event of a malfunction,
change the whole tap.
Operating instructions
Burner locations
1
Pan supports
2
Control knobs
3
Auxiliary burner (up to 1 kW)
4
Semi-rapid burner (up to 1.75 kW)
5
Rapid burner (up to 3 kW)
6
Double-flame wok burner (up to 3.3 kW)
Accessories
Depending on the model, the hob may include the following
accessories. These can also be acquired from the Technical
Assistance Service.
--------
The manufacturer accepts no liability if these accessories are
not used or are used incorrectly.
3%+%$
1
2
3%3$$
1
2
Additional wok pan support
Only for use on wok burners
with pans with a round base.
Using these pans may cause
some temporary deformation
of the grease drip tray. This is
normal and does not affect
the operation of the appli-
ance.
Additional coffee maker
support
Only for use on the auxiliary
burner with pans which are no
more than 12 cm in diameter.