PAVIRO Call Stations
Installation | en
23
Bosch Security Systems
2018.04 | 04 | F01U306899
6.
Mount the button into the installation location, and press in
evenly (it must be possible for the cover cap to open
upward).
7.
Depending on whether the right/middle/left installation
location is used, plug the ribbon cable
➍
into plug
connector CN201/CN202/CN203 on the circuit board.
8.
Plug the connecting cable into CN1 again.
9.
Carefully re-attach the call station baseplate.
10. Re-connect the connections.
11. Configure the button using the software.
The call station can be retrofitted with a maximum of three
covered buttons PVA-1EB and / or one key switch PVA-1KS.
Additional control elements can be used, for example for
triggering alarms in certain areas (selection alarm) or for
switching the system ON/OFF. The functions are assigned via
IRIS-Net during configuration.
5.3.2
Key switch
The PVA-1KS is an optional key switch for installation in the call
station. The key switch feed lines are monitored by the control
station. If an error occurs, this is indicated in the error log of the
system.
Figure
5.2: PVA-1KS
Assembly
Note the following information regarding installation of the key
switch in the call station.
1.
Disconnect the call station from all connectors
2.
Unscrew the call station baseplate (4 screws)
3.
Carefully remove the baseplate from the upper part,
starting on the top left corner of the call station.
4.
Unplug the connecting cable from the CN1 plug connector