background image

FlexiDome IP Camera

NDC-455

en

Installation and Operation Manual

Содержание NDC-455

Страница 1: ...FlexiDome IP Camera NDC 455 en Installation and Operation Manual ...

Страница 2: ......

Страница 3: ...ction 16 2 1 Features 16 3 System Information 18 3 1 Overview of functions 18 3 1 1 Progressive scan 18 3 1 2 Tri streaming 18 3 1 3 ONVIF Open Network Video Interface Forum 18 3 1 4 Audio 18 3 1 5 Alarm I O 18 3 1 6 Tamper detection and motion detectors 19 3 1 7 Impact resistant dome with tamper resistant housing 19 3 1 8 Video encoding 19 3 1 9 Multicast 19 3 1 10 Power over Ethernet 19 3 1 11 E...

Страница 4: ... 3 Make the connections 31 5 2 4 Indication LED 33 5 2 5 Reset button 33 5 2 6 Mount the camera 33 5 3 Camera positioning 34 5 3 1 Focal length and focus 35 5 3 2 Closing the unit 36 6 Camera set up 37 6 1 Camera menu navigation 37 6 2 Install menu 38 6 2 1 Network submenu 39 6 2 2 Defaults submenu 39 6 2 3 Lens Wizard submenu 40 7 Browser connection 41 7 1 System requirements 41 7 2 Establishing ...

Страница 5: ... 48 8 4 Network 49 8 5 Encoder Profile 50 8 6 Audio 50 8 7 Recording 50 8 7 1 Storage medium 50 8 8 System Overview 50 9 Advanced Mode 51 9 1 Advanced Mode menu tree 51 9 2 General 53 9 2 1 Identification 53 9 2 2 Password 53 9 2 3 Date Time 54 9 2 4 Display Stamping 56 9 3 Web Interface 58 9 3 1 Appearance 58 9 3 2 LIVEPAGE Functions 59 9 3 3 Logging 60 9 4 Encoder 61 9 4 1 Privacy Masks 61 9 4 2...

Страница 6: ...es VCA 80 9 8 3 VCA configuration Profiles 81 9 8 4 VCA configuration Scheduled 87 9 8 5 VCA configuration Event triggered 89 9 8 6 Audio Alarm 90 9 8 7 Alarm E Mail 91 9 8 8 Alarm Task Editor 93 9 9 Interfaces 94 9 9 1 Alarm input 94 9 9 2 Relay 94 9 10 Network 96 9 10 1 Network 96 9 10 2 Advanced 100 9 10 3 Multicasting 101 9 10 4 JPEG Posting 102 9 10 5 Encryption 103 9 11 Service 104 9 11 1 Ma...

Страница 7: ... Running recording program 109 10 1 8 Audio communication 109 10 2 Recordings page 110 10 2 1 Controlling playback 110 11 Troubleshooting 112 11 1 Function test 112 11 2 Resolving problems 113 11 3 Customer service 115 12 Maintenance 116 12 1 Testing the network connection 116 12 2 Repairs 116 12 2 1 Transfer and disposal 116 13 Technical Data 117 13 1 Specifications 117 13 1 1 Dimensions 120 13 1...

Страница 8: ...tuation such as Dangerous Voltage inside the product If not avoided this will result in an electrical shock serious bodily injury or death WARNING Medium risk Indicates a potentially hazardous situation If not avoided this could result in minor or moderate bodily injury CAUTION Low risk Indicates a potentially hazardous situation If not avoided this could result in property damage or risk of damag...

Страница 9: ...r equipment including amplifiers that produce heat 3 Never spill liquid of any kind on the unit 4 Take precautions to protect the unit from power and lightning surges 5 Adust only those controls specified in the operating instructions 6 Operate the unit only from the type of power source indicated on the label 7 Unless qualified do not attempt to service a damaged unit yourself Refer all servicing...

Страница 10: ...er supplied wiring must be in compliance with electrical codes Class 2 power levels If 24 VAC is used do not ground the 24 VAC supply at the terminals or at the unit s power supply terminals PoE Use only approved PoE devices Power over Ethernet can be connected at the same time as a 12 VDC or 24 VAC power supply Earth connection The unit must be connected to earth Connection The unit has connectio...

Страница 11: ... can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipment and receiver connect the equipment into an outlet on a circuit different from that to which the receiver is connected consult the dealer or an experienced ra...

Страница 12: ...particulière Il est possible de déterminer la production d interférences en mettant l appareil successivement hors et sous tension tout en contrôlant la réception radio ou télévision L utilisateur peut parvenir à éliminer les interférences éventuelles en prenant une ou plusieurs des mesures suivantes Modifier l orientation ou l emplacement de l antenne réceptrice Éloigner l appareil du récepteur B...

Страница 13: ...cts of this product UL MAKES NO REPRESENTATIONS WARRANTIES OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED FUNCTIONS OF THIS PRODUCT Disposal Your Bosch product was developed and manufactured with high quality material and components that can be recycled and reused This symbol means that electronic and electrical appliances which have reac...

Страница 14: ... protected by copyright All rights reserved Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly Note This manual has been compiled with great care and the information it contains has been thoroughly verified The text was complete and correct at the time of printing The ongoing development of the products ma...

Страница 15: ...ital Equipment Corporation Permission to use copy modify distribute and sell this software and its documentation for any purpose and without fee is hereby granted provided that the above copyright notices appear in all copies and that both those copyright notices and this permission notice appear in supporting documentation and that the names of Adobe Systems and Digital Equipment Corporation not ...

Страница 16: ...s and the Internet The camera is easy to install and ready to use Features include Progressive scan Color performance with NightSense 1 3 inch CCD sensor Tri streaming two H 264 streams and one M JPEG stream Complies with the ONVIF standard for wide compatibility Two way audio and audio alarm Alarm input and alarm output to external devices Impact resistant dome IK10 Tamper resistant housing Enhan...

Страница 17: ...h Security Systems Installation and Operation Manual AR18 10 B006 v1 1 2010 06 Fast convenient configuration using the integrated Web server and a browser Firmware update through flash memory Convenient upload and download of configuration data ...

Страница 18: ...ures and processes progressively scanned images When there is fast motion in a scene progressively scanned images are generally sharper than interlaced images 3 1 2 Tri streaming Tri streaming allows the data stream to be encoded simultaneously according to three different individually customized profiles This creates two full H 264 streams that can serve different purposes and an additional M JPE...

Страница 19: ...oding The camera uses the H 264 compression standards Thanks to efficient encoding the data rate remains low even with high image quality and can also be adapted to local conditions within wide limits 3 1 9 Multicast In suitably configured networks the multicast function enables simultaneous real time transmission to multiple receivers The prerequisite for this is that the UDP and IGMP V2 protocol...

Страница 20: ...deo frames snapshots can be called up as JPEG images stored on the hard drive or displayed in a separate browser window 3 1 15 Backup The browser application has an icon for saving the video images provided by the unit as a file on your computer s hard drive Clicking this icon stores the video sequences and they can be replayed with the Player from Bosch Security Systems included with the package ...

Страница 21: ...udio and data across any IP network It is designed to work with Bosch CCTV products as part of a total video surveillance management system Integrate your existing components into one easy to manage system or use Bosch s full line capabilities and benefit from a complete surveillance solution based on cutting edge technology and years of experience VIDOS The camera video server and VIDOS software ...

Страница 22: ... camera such as controlling relays remote control of peripheral devices and remote configuration DiBos can use alarm inputs to trigger actions and when motion detection Motion is active can record the relevant cells making intelligent motion detection possible Divar 700 Series The Divar 700 Series of digital video recorders can view and record images from the camera via a network connection The Di...

Страница 23: ...er bit for tamper resistant screws Lens adjustment cap RJ45 female to female network cable connector Template for flush mount DVD ROM mini Manual System requirements Configuration Manager BVIP Lite Suite MPEG ActiveX control DirectX control Microsoft Internet Explorer Sun JVM Player and Archive Player Adobe Acrobat Reader Quick install instructions Safety instructions If equipment has been damaged...

Страница 24: ...tems such as VIP XD as a receiver and a connected video monitor or Divar 700 Series Digital Video Recorder The minimum PC requirements are Operating platform A PC running Windows XP or Windows Vista with IE 7 0 Processor Dual core 3 0 GHz RAM memory 256 MB Monitor resolution 1024 x 768 Network interface 100 BaseT DirectX 9 0c Make sure the graphics card is set to 16 bit or 32 bit color depth and t...

Страница 25: ...the DVD into the DVD ROM drive of the computer If the DVD does not start automatically open the DVD in Windows Explorer and double click the index html file to start the installation 2 Select a language from the list box at the top 3 Click Tools in the menu 4 Click Archive Player the installation starts 5 Follow the instructions in the installation program The Archive Player is installed together ...

Страница 26: ...ing parts To disassemble the unit proceed as follows 1 Using the special screwdriver bit loosen the three tamper resistant screws in the trim ring the screws remain in place CAUTION Installation should only be performed by qualified service personnel in accordance with the National Electrical Code or applicable local codes 1 Surface mount box 2 Camera module and mounting base 3 Inner liner with se...

Страница 27: ...era module in place no keyhole 6 Rotate the camera module to remove it from the remaining two screws 5 1 2 Flush mount version The camera housing unit consists of the following parts To disassemble the unit proceed as follows 1 Using the special screwdriver bit loosen the three tamper resistant screws in the trim ring the screws remain in place 2 Remove the trim ring with dome by pulling it off of...

Страница 28: ...ace mounted then use the Surface Mount Box SMB The SMB is sold as a separate item VDA 455SMB but the inner plastic cover should be removed as it is only needed for analog cameras Certain versions of the FlexiDome are supplied with the Surface Mount Box already included please check the ordering number Other mounting accessories are also sold separately Refer to the dimensions drawing to find the e...

Страница 29: ...e mount box 1 With a side connection remove the cap covering the side entrance With a rear connection leave the cap in place 2 Attach the conduit to the surface mount box 3 Attach the surface mount box to the surface 4 Suspend the camera base from the plastic hook inside the surface mount box until the connections are made Note The surface mount box can be attached to a 4S box if required ...

Страница 30: ...xiDome IP Camera AR18 10 B006 v1 1 2010 06 Installation and Operation Manual Bosch Security Systems 5 2 2 Flush mount Figure 1 Flush mounting 57 6 2 27 57 6 2 27 95 3 74 33 3 1 31 66 5 2 62 Ø 8 m m 3x Ø 8 m m 3x PCD 133 5 25 ...

Страница 31: ...ater Cable tree Use the following table to identify the wires in the cable tree Power connection 1 Use a class 2 power supply 24 VAC or 12 VDC 2 Connect the power wires red brown to the power supply connector 3 Connect the earth wire yellow green from the camera to the system earth of the installation to ensure correct EMC RFI and safety protection Note For a DC supply the polarity is important In...

Страница 32: ...isted pair STP connection cable and need to meet the EMC Alarm immunity standard EN50130 4 or the EMC Railway imunity standard EN50121 4 a shielded RJ45 female to female network cable connector not supplied shall be used Alarm input output Use the alarm input to connect external alarm devices such as door contacts or sensors A zero potential make contact or switch can be used as the actuator use a...

Страница 33: ...aximum cable lengths for audio line input and output levels 5 2 4 Indication LED The multicolored LED beside the navigation buttons indicates Power red IP connection green and IP traffic green flashing It can be disabled in the Settings Camera Installer Options menu 5 2 5 Reset button With the power on use a small pointed object to press and hold the reset button beside the navigation buttons for ...

Страница 34: ... the miniature 2 5 mm jack socket on the printed circuit board using the optional monitor cable S1460 This monitor jack socket provides a composite video signal with sync for installation purposes only 1 Heater 2 Monitor jack socket 3 Thumbwheels 4 Navigation buttons 5 indication LED and reset button 5 Focal length 6 Focus A Pan axis rotation B Tilt axis rotation C Twist axis rotation A B C ...

Страница 35: ...ceilings or sidewall mounting rotate the base of the lens as necessary to align the picture shown on the monitor Do not rotate more than 340 5 3 1 Focal length and focus Before adjusting place the adjustment cap on the lens to ensure that the image sharpness is the same as when the dome is in place 1 Press and hold the menu select center button until the Install menu appears Select the Set Back Fo...

Страница 36: ...sing the unit When the camera position is set and all adjustments have been made close the unit 1 If necessary remove the monitor cable S1460 from the monitor jack socket 2 Place the inner liner in position aligning its fin with the bracket on the base 3 Place the dome onto the base and rotate until it clips into place If necessary clean its surface with a soft cloth 4 Place the sealing ring and t...

Страница 37: ...d for navigating through menu system To open the install menu and enable the analog video output press and hold the center key for approximately two seconds This turns off the IP video stream Use the up or down keys to scroll through a menu Use the left or right keys to move through options or to set parameters When in a menu quickly double press the menu select key to restore the selected item to...

Страница 38: ...e unit is shown This is factory set and cannot be changed To ensure that the correct MAC address is displayed wait 20 seconds after power up before opening the Install menu The items in the Install menu include the Mode selection the Lens Wizard submenu the Network submenu and the Defaults submenu Note Camera parameter set up is done via IP See Section 9 6 Camera for the specific camera menus ...

Страница 39: ...n IP Address Enter an IP address for the camera Use LEFT RIGHT to change position in the address use UP DOWN to select the digit Use SELECT to exit the address edit screen Subnet Mask Enter the Subnet mask default 255 255 255 0 Gateway Enter a Gateway address DHCP If the network has a DHCP server for dynamic IP address allocation set this parameter to On to activate the automatic acceptance of DHC...

Страница 40: ...ty Systems 6 2 3 Lens Wizard submenu Item Selection Description Set Backfocus now Select to fully open the iris Follow the instructions for setting the backfocus for your particular lens type After focusing the object of interest remains in focus under bright and low light conditions EXIT Returns to Install menu ...

Страница 41: ...rements Microsoft Internet Explorer version 7 0 or higher Monitor resolution at least 1024 768 pixels 16 or 32 bit color depth Sun JVM installed Intranet or Internet network access The Web browser must be configured to enable Cookies to be set from the IP address of the unit In Windows Vista deactivate protected mode on the Security tab under Internet Options Read the information in the System Req...

Страница 42: ...S or Bosch VMS connections are supported 7 2 1 Password protection in camera A camera offers the option of limiting access across various authorization levels If the camera is password protected a message to enter the password appears 1 Enter the user name and the associated password in the appropriate fields 2 Click OK If the password is correct the desired page is displayed 7 3 Protected network...

Страница 43: ...art of the same closed network In this way it is possible to cover large distances with little installation or cabling effort 7 4 1 Alarm connection With the appropriate configuration a connection between camera and decoder is established automatically when an alarm is triggered After a short time the live video image from the transmitter is shown on the connected monitor In this case no computer ...

Страница 44: ...nk is only visible if a storage medium is available Figure 7 1 Livepage 7 5 1 LIVEPAGE The LIVEPAGE is used to display and control the video stream Refer to Section 10 Operation via the browser page 107 for more information 7 5 2 RECORDINGS Click RECORDINGS in the application title bar to open the playback page Refer to Section 10 Operation via the browser page 107 for more information 7 5 3 SETTI...

Страница 45: ...tal functioning of the unit for example firmware updates can only be made using the configuration menu The configuration menu tree allows all parameters of the unit to be configured The configuration menu is divided into Basic Mode and Advanced Mode Refer to Section 8 Basic Mode page 46 for more information on basic settings refer to Section 9 Advanced Mode page 51 for more information on advanced...

Страница 46: ... defined value in a list field Saving changes After making changes in a window click Set to send the new settings to the device and save them there Clicking Set saves only the settings in the current window Changes in any other windows are ignored Click SETTINGS in the applications title bar to close the window without saving the changes Note Device time settings are lost after 1 hour without powe...

Страница 47: ...mera and allows all configuration settings to be changed user is the middle authorization level This user can operate the device play back recordings and also control a camera but cannot change the configuration live is the lowest authorization level It can only be used to view the live video image and switch between the different live image displays Use the various authorization levels to limit a...

Страница 48: ... is not necessary to enter the day or date of the week These are set automatically The time zone in which the system is located is also set automatically 1 Click Sync to PC to apply the system time from your computer to the device Time server IP address The camera can receive the time signal from a time server using various time server protocols and then use it to set the internal clock The device...

Страница 49: ...dress allocation set this parameter to On to activate the automatic acceptance of DHCP assigned IP addresses Note Certain applications for example Bosch Video Management System use the IP address for the unique assignment of the device If using these applications the DHCP server must support the fixed assignment between IP address and MAC address and must be appropriately set up so that once an IP...

Страница 50: ...put levels with the sliders 8 7 Recording Record the images from the camera to a storage medium For long term authoritative images it is essential to use a Divar 700 Series Digital Video Recorder or an appropriately sized iSCSI system 8 7 1 Storage medium 1 Select the required storage medium from the list 2 Click Start to start recording or Stop to end recording 8 8 System Overview This page provi...

Страница 51: ...menu sub heading to expand it 3 Click a sub menu The corresponding page is opened The settings are changed by entering new values or by selecting a pre defined value in a list field Saving changes After making changes in a window click Set to send the new settings to the device and save them there Clicking Set saves only the settings in the current window Changes in any other windows are ignored C...

Страница 52: ...ration Manual Bosch Security Systems Note Device time settings are lost after 1 hour without power if no central time server is selected Note When entering names do not use any special characters for example Special characters are not supported by the internal recording management system ...

Страница 53: ...le to identify the location unambiguously Initiator extension Add text to an initiator name to make identification easier in large iSCSI systems This text is added to the initiator name separated from it by a full stop 9 2 2 Password A password prevents unauthorized access to the device The device recognizes three authorization levels service user and live service is the highest authorization leve...

Страница 54: ...r each level while logged in as service or if the device is not protected by a password Enter the password for the selected level Confirm password Re enter the new password to ensure that there are no typing mistakes The new password is only saved after clicking Set Therefore click Set immediately after entering and confirming the password even if assigning a password at another level 9 2 3 Date T...

Страница 55: ...f a table is not created there is no automatic switching When editing the table note that values occur in linked pairs DST start and end dates First check the time zone setting If it is not correct select the appropriate time zone for the system 1 Click Set 2 Click Details A new window opens showing an empty table 3 Click Generate to fill the table with the preset values from the camera 4 Select t...

Страница 56: ...tocol 9 2 4 Display Stamping Various overlays or stamps in the video image provide important supplementary information These overlays can be enabled individually and arranged on the image in a clear manner Camera name stamping This field sets the position of the camera name overlay It can be displayed at the Top at the Bottom or at a position of choice using the Custom option or it can be set to O...

Страница 57: ...be displayed at a position of choice using the Custom option or it can be set to Off for no overlay information If the Custom option is selected enter values in the X and Y position fields Alarm message Enter the message to be displayed on the image in the event of an alarm The maximum text length is 31 characters Video watermarking Select On for the transmitted video images to be watermarked Afte...

Страница 58: ...rnet Intranet For access via the Internet Intranet there must be a connection in order to display the image The image files are not stored on the camera To restore the original graphics delete the entries in the Company logo and Device logo fields Website language Select the language for the user interface here Company logo Enter the path to a suitable image in this field The image can be stored o...

Страница 59: ... inputs are displayed next to the video image as icons along with their assigned names If an alarm is active the corresponding icon changes color Show relay outputs The relay output is shown next to the video image as an icon along with its assigned name If a relay is switched the icon changes color Show VCA trajectories The trajectories motion lines of objects from the video content analysis are ...

Страница 60: ...ly be saved if this icon is visible Path for JPEG and video files Enter the path for the storage location of individual images and video sequences saved from the Livepage If necessary click Browse to find a suitable folder 9 3 3 Logging Save event log Select this option to save event messages in a text file on the local computer This file can be viewed edited and printed with any text editor or st...

Страница 61: ...tures The camera simultaneously generates two H 264 video streams and an M JPEG stream Tri streaming Select the compression settings of these streams individually for example one setting for transmissions to the Internet and one for LAN connections The settings are made individually for each stream Define profiles Eight definable profiles are available The pre programmed profiles give priority to ...

Страница 62: ...to use the default profiles Only change a profile if completely familiar with all the configuration options The parameters as a group constitute a profile and are dependent on one another If a setting outside the permitted range for a parameter is entered the nearest valid value is substituted when the settings are saved Profile name Enter a new name for the profile here Target data rate To optimi...

Страница 63: ...240 pixels 4CIF D1 704 576 480 pixels Expert Settings if necessary use the expert settings to adapt the I frame quality and the P frame quality to specific requirements The setting is based on the H 264 quantization parameter QP I frame quality This setting adjusts the image quality of the I frames The basic setting Auto automatically adjusts the quality to the settings for the P frame video quali...

Страница 64: ...Security Systems The value 9 represents the best image quality with if necessary a lower frame refresh rate depending on the settings for the maximum data rate A value of 51 results in a very high refresh rate and lower image quality Default Click Default to return the profile to the factory default values ...

Страница 65: ... 1 Click Preview to display a preview of the video for streams 1 and 2 the current profile is shown above the preview 2 Click 1 1 Live View below a preview to open a viewing window for that stream Various additional items of information are shown across the top of the window 3 Click Preview to close the preview displays Note Deactivate the display of the video images if the performance of the comp...

Страница 66: ...ution follows the highest resolution setting either in stream 1 or stream 2 For example if stream 1 is 4CIF D1 and stream 2 is CIF the JPEG resolution will be 4CIF D1 9 5 Audio Switch the camera audio On or Off Adjust the input and output levels with the sliders Note The audio signals are sent in a separate data stream parallel to the video data and so increase the network load The audio data requ...

Страница 67: ...maintain the selected shutter speed 1 60 1 50 1 100 1 120 1 250 1 500 1 1000 1 2000 1 5000 1 10K as long as the light level of the scene permits FL flickerless mode avoids interference from light sources recommended for video iris or DC iris lenses only Actual shutter Displays the actual shutter value from the camera to help compare lighting levels and optimum shutter speed during set up Gain When...

Страница 68: ...g objects 9 6 2 Enhance Back Light Compensation Auto black When ON the video level is optimized for the center of the image Parts outside this area may be underexposed or overexposed this is normal Auto black Auto black ON automatically increases the visibility of details 9 6 3 Color White balance ATW Auto tracking white balance allows the camera to continually adjust for optimal color reproductio...

Страница 69: ...sable the Camera buttons on the camera to prevent unauthorized change of the camera settings Camera LED Disable the Camera LED on the camera to switch it off Show test pattern Select On to show a video test signal Pattern Select the desired test pattern to help with installation and fault finding Restore all defaults Click Restore all defaults to restore the factory defaults for the camera A confi...

Страница 70: ...ustomer service at Bosch Security Systems 9 7 1 Storage Management Device manager If the VRM option is activated the VRM Video Recording Manager manages all recording and no further settings can be configured here Note Activating or deactivating VRM causes the current settings to be lost they can only be restored through reconfiguration Recording media Select the required recording media to activa...

Страница 71: ... the storage media in this list and configure them for storage Note Each storage medium can only be associated with one user If a storage medium is already being used by another user decouple the user and connect the drive to the camera Before decoupling make absolutely sure that the previous user no longer needs the storage medium 1 In the Storage overview section double click the required storag...

Страница 72: ...Formatting Storage Media Delete all recordings on a storage medium at any time Check the recordings before deleting and back up important sequences on the computer s hard drive 1 Click a storage medium in the Managed storage media list to select it 2 Click Edit below the list A new window opens 3 Click Formatting to delete all recordings in the storage medium 4 Click OK to close the window Deactiv...

Страница 73: ...t the profile setting that is to be used for each data stream when recording This selection is independent of the selection for live data stream transmission The properties of the profiles are defined on the Encoder Profile page Recording includes Specify whether in addition to video data audio or metadata for example alarms or VCA data should also be recorded Including metadata could make subsequ...

Страница 74: ...e Alarm input Motion Audio alarm Video loss alarm that is to trigger a recording Select the Virtual alarm sensors that are to trigger a recording via RCP commands or alarm scripts for example 9 7 3 Retention Time Specify the retention times for recordings If the available memory capacity of a medium has been used older recordings are only overwritten if the retention time entered here has expired ...

Страница 75: ...button to deselect any of the intervals 4 Click Select All to select all of the intervals to be assigned to the selected profile 5 Click Clear All to deselect all of the intervals 6 When finished click Set to save the settings to the device Holidays Define holidays whose settings will override the settings for the normal weekly schedule 1 Click the Holidays tab Days that have already been defined ...

Страница 76: ...d the Recording Profiles and the Recording Scheduler are deactivated and the configuration cannot be modified Terminate recording at any time to modify the configuration 1 Click Start to activate the recording schedule 2 Click Stop to deactivate the recording schedule Recordings that are currently running are interrupted and the configuration can be modified Recording status The graphic indicates ...

Страница 77: ...input 1 so that the device maintains the connection for as long as an alarm exists Number of destination IP address Specify the numbers of the IP addresses to be contacted in the event of an alarm The device contacts the remote locations one after the other in the numbered sequence until a connection is made Destination IP address For each number enter the corresponding IP address for the desired ...

Страница 78: ...alarm a larger bandwidth must be available on the network for additional video images if Multicast operation is not possible To enable Multicast operation select the UDP option for the Video transmission parameter here and on the Network page Remote port Select a browser port depending on the network configuration The ports for HTTPS connections are only available if the On option in SSL encryptio...

Страница 79: ...for establishing a connection such as the password By selecting On only encrypted ports are available for the Remote port parameter SSL encryption must be activated and configured on both sides of a connection The appropriate certificates must also have been uploaded Configure and activate encryption for media data video metadata on the Encryption page Auto connect Select On to automatically re es...

Страница 80: ...ur application as required The Silent MOTION configuration is active by default In this configuration metadata is created to facilitate searches of recordings however no alarm is triggered 1 Select a VCA configuration and make the required settings 2 If necessary click the Default button to return all settings to their default values Note If there is not enough computing power priority is given to...

Страница 81: ...a saved profile A new window opens in which to select the profile file and specify where to save the file To rename a profile 1 To rename the file click the icon to the right of the list field and enter the new profile name in the field 2 Click the icon again The new profile name is saved The current alarm status is displayed for information purposes Aggregation time s Set an aggregation time of b...

Страница 82: ...ctivated At least one sensor field must be activated The individual parameters must be configured to suit the operating environment and the desired responses The sensitivity must be set to a value greater than zero Note Reflections of light from glass surfaces etc lights switching on and off or changes in the light level caused by cloud movement on a sunny day can trigger unintended responses from...

Страница 83: ...or fields Activate or deactivate each of these fields individually To exclude particular regions of the camera s field of view from monitoring due to continuous movement by a tree in the wind for example the relevant fields can be deactivated 1 Click Select Area to configure the sensor fields A new window opens 2 If necessary click Clear All first to clear the current selection fields marked red 3...

Страница 84: ...red by short term changes for example cleaning activities in the direct field of vision of the camera Global change slider Set how large the global change in the video image must be for an alarm to be triggered This setting is independent of the sensor fields selected under Select Area Set a high value if fewer sensor fields need to change to trigger an alarm With a low value it is necessary for c...

Страница 85: ... is triggered This detects tampering that would otherwise not be detected for example if the camera is turned 1 Click Reference to save the currently visible video image as a reference 2 Click Select Area and select the areas in the reference image that are to be monitored 3 Check the box Reference check to activate the on going check The stored reference image is displayed in black and white belo...

Страница 86: ... these fields individually Select only those areas for reference monitoring in which no movement takes place and that are always evenly lit as false alarms could otherwise be triggered 1 Click Select Area to configure the sensor fields A new window opens 2 If necessary click Clear All first to clear the current selection fields marked yellow 3 Left click the fields to be activated Activated fields...

Страница 87: ...lected profile 3 Use the right mouse button to deselect any of the intervals 4 Click Select All to link all time intervals to the selected profile 5 Click Clear All to deselect all of the intervals 6 When finished click Set to save the settings in the device Holidays Define holidays on which a profile should be active that are different to the standard weekly schedule 1 Click the Holidays tab Any ...

Страница 88: ...iDome IP Camera AR18 10 B006 v1 1 2010 06 Installation and Operation Manual Bosch Security Systems 3 Click OK The item is deleted from the table and the window closes 4 The process must be repeated for deleting additional days ...

Страница 89: ...Select the VCA configuration here that is to be enabled via an active trigger A green check mark to the right of the list field indicates that the trigger is active Trigger inactive Select the VCA configuration here that is to be activated if the trigger is not active A green check mark to the right of the list field indicates that the trigger is inactive Delay s Select the delay period for the re...

Страница 90: ...s for example with the VIDOS and Bosch Video Management System programs Enter a unique and clear name here Signal Ranges Exclude particular signal ranges in order to avoid false alarms For this reason the total signal is divided into 13 tonal ranges mel scale Check or uncheck the boxes below the graphic to include or exclude individual ranges Threshold Set up the threshold on the basis of the sign...

Страница 91: ...nsfer Protocol Outgoing e mails are sent to the mail server via the address entered Otherwise leave the box blank 0 0 0 0 SMTP user name Enter a registered user name for the chosen mail server SMTP password Enter the required password for the registered user name Format Select the data format of the alarm message Standard with JPEG e mail with JPEG image file attachment SMS e mail in SMS format to...

Страница 92: ...Enter the e mail address for alarm e mails here The maximum address length is 49 characters Sender name Enter a unique name for the e mail sender for example the location of the device This makes it easier to identify the origin of the e mail Test e mail Click Send Now to test the e mail function An alarm e mail is immediately created and sent ...

Страница 93: ... product DVD supplied As an alternative to the alarm settings on the various alarm pages enter the desired alarm functions in script form here This will overwrite all settings and entries on the other alarm pages 1 Click Examples under the Alarm Task Editor field to see some script examples A new window opens 2 Enter new scripts in the Alarm Task Editor field or change existing scripts in line wit...

Страница 94: ...gered See Section 9 8 8 Alarm Task Editor page 93 for information on alarm actions based on alarm inputs 9 9 2 Relay Configure the switching behavior of the relay output Select different events that automatically activate an output For example turn on a floodlight by triggering a motion alarm and then turn the light off again when the alarm has stopped Idle state Select Open for the relay to opera...

Страница 95: ...dvanced Mode en 95 Bosch Security Systems Installation and Operation Manual AR18 10 B006 v1 1 2010 06 Trigger relay Click the button to switch the relay manually for example for testing purposes or to operate a door opener ...

Страница 96: ...ter the reboot Automatic IP assignment If a DHCP server is employed in the network for the dynamic assignment of IP addresses activate acceptance of IP addresses automatically assigned to the device Certain applications VIDOS Bosch Video Management System Archive Player Configuration Manager use the IP address for the unique assignment of the device If using these applications the DHCP server must...

Страница 97: ...he device is used behind a firewall TCP Port 80 should be selected as the transmission protocol For use in a local network choose UDP Multicast operation is only possible with the UDP protocol The TCP protocol does not support multicast connections The MTU value in UDP mode is 1514 bytes HTTP browser port Select a different HTTP browser port from the list if required The default HTTP port is 80 To...

Страница 98: ...ections on this port To allow only encrypted connections set the Off option to deactivate telnet support making telnet connections impossible Interface mode ETH If necessary select the Ethernet link type for interface ETH Depending on the device connected it may be necessary to select a special operation type Network MSS Byte Set the maximum segment size for the IP packet s user data here This giv...

Страница 99: ...t DynDNS org Host name Enter the host name registered on DynDNS org for the device here User name Enter the user name registered at DynDNS org here Password Enter the password registered at DynDNS org here Force registration now Force the registration by transferring the IP address to the DynDNS server Entries that change frequently are not provided in the Domain Name System It is a good idea to f...

Страница 100: ...t send the traps automatically and will only reply to SNMP requests If one or two SNMP host addresses are entered SNMP traps are sent automatically Select Off to deactivate the SNMP function 1 SNMP host address 2 SNMP host address To send SNMP traps automatically enter the IP addresses of one or two target devices here SNMP traps To choose which traps are sent 1 Click Select A dialog box appears 2...

Страница 101: ...erequisite for multicast operation is a multicast capable network that uses the UDP and IGMP protocols Other group membership protocols are not supported The TCP protocol does not support multicast connections A special IP address class D address must be configured for multicast operation in a multicast enabled network The network must support group IP addresses and the Internet Group Management P...

Страница 102: ...alue can be entered to specify how long the multicast data packets are active on the network If multicast is to be run via a router the value must be greater than 1 9 10 4 JPEG Posting Save individual JPEG images on an FTP server at specific intervals If required retrieve these images at a later date to reconstruct alarm events JPEG resolution corresponds to the highest setting from the two data s...

Страница 103: ...the images are sent to an FTP server Enter zero for no images to be sent FTP server IP address Enter the IP address of the FTP server on which to save the JPEG images FTP server login Enter your login name for the FTP server FTP server password Enter the password that gives access to the FTP server Path on FTP server Enter an exact path to post the images on the FTP server 9 10 5 Encryption If an ...

Страница 104: ...oad area To update the firmware 1 First store the firmware file on your hard disk 2 Enter the full path for the firmware file in the field or click Browse to locate and select the file 3 Click Upload to begin transferring the file to the device The progress bar allows monitoring of the transfer Service Maintenance Licenses System Overview CAUTION Before starting a firmware update make sure to sele...

Страница 105: ...gs 1 Click Download a dialog box appears 2 Follow the instructions to save the current settings To load configuration data from the computer to the device 1 Enter the full path of the file to upload or click Browse to select the desired file 2 Make certain that the file to be loaded comes from the same device type as the device to be reconfigured 3 Click Upload to begin transmission to the device ...

Страница 106: ... Download an internal maintenance log from the device to send it to Customer Service for support purposes Click Download and select a storage location for the file 9 11 2 Licenses This window is for the activation of additional functions by entering activation codes An overview of installed licenses is shown 9 11 3 System Overview This window is for information only and cannot be modified Keep thi...

Страница 107: ... various text overlays may be visible on the live video image Other information may also be shown next to the live video image on the Livepage The display depends on the settings on the LIVEPAGE Functions page Figure 10 1 Livepage 10 1 1 Processor load When accessing the camera with a browser the processor load and network information is available in the upper right of the window next to the Bosch...

Страница 108: ...lay symbol The symbol is red when the relay is activated 10 1 4 System Log Event Log The System Log field contains information about the operating status of the camera and the connection These messages can be saved automatically in a file Events such as the triggering or end of alarms are shown in the Event Log field These messages can be saved automatically in a file To delete the entries from th...

Страница 109: ...ch Security Systems 10 1 7 Running recording program The hard drive icon below the camera images on the Livepage changes during an automatic recording The icon lights up and displays a moving graphic to indicate a running recording If no recording is taking place a static icon is displayed 10 1 8 Audio communication Audio can be sent and received via the Livepage if the active monitor and the remo...

Страница 110: ... are identical only the quality and locaction may be different 10 2 1 Controlling playback A time bar below the video image allows quick orientation The time interval associated with the sequence is displayed in the bar in gray A green arrow above the bar indicates the position of the image currently being played back within the sequence The time bar offers various options for navigation in and be...

Страница 111: ...ences so called bookmarks and jump directly to these These bookmarks are indicated as small yellow arrows above the time interval Use the bookmarks as follows Jump to the previous bookmark Set bookmark Jump to the following bookmark Bookmarks are only valid while in the Recordings page they are not saved with the sequences All bookmarks are deleted when you leave the page Trick mode View recording...

Страница 112: ... Therefore check that it works properly after installation and configuration This is the only way to ensure that the camera will function as intended in the event of an alarm Your check should include the following functions Can the camera be called up remotely Does the camera transmit all the data required Does the camera respond as desired to alarm events Is it possible to control peripheral dev...

Страница 113: ...ections Check all cables plugs contacts and connections Incorrect encoder stream property set for connection to hardware decoder Select the H 264 BP HW decoder option on the Encoder Streams configuration page No connection established no image transmission The unit s configuration Check all configuration parameters Faulty installation Check all cables plugs contacts and connections Wrong IP addres...

Страница 114: ...nection is free and then call the sender again The unit does not report an alarm Alarm source is not selected Select possible alarm sources on the Alarm sources configuration page No alarm response specified Specify the desired alarm response on the Alarm connections configuration page if necessary change the IP address Control of cameras or other units is not possible The cable connection between...

Страница 115: ...rite down the information or print out the page The unit is not operational after a firmware upload Power failure during programming by firmware file Have the unit checked by Customer Service and replace if necessary Incorrect firmware file Enter the IP address of the unit followed by main htm in your Web browser and repeat the upload Placeholder with a red cross instead of the ActiveX components ...

Страница 116: ...erly connected to the network Check the cable connections in this case The device is not correctly integrated into the network Check the IP address subnet mask and gateway address 12 2 Repairs 12 2 1 Transfer and disposal The camera should only be passed on together with this installation guide The unit contains environmentally hazardous materials that must be disposed of according to law Defectiv...

Страница 117: ...ly voltage 12 VDC 500 mA IVA 650 mA 24 VAC 500 mA IVA 650 mA PoE 48 VDC 200 mA Power consumption 8 W Color NightSense Auto Forced Dynamic range 50 dB 10 bit image processing SNR 50 dB BLC Center window weighting AGC AGC On 20 dB or Off White Balance ATW AWB hold 2500 to 10000K AutoBlack Automatic continuous Off Shutter AES 1 60 1 50 to 1 150000 automatic flickerless or fixed Privacy Masking Four i...

Страница 118: ... pixels 25 30 IPS Group of pictures I IP IPBB Image refresh rate Field image based coding 1 to 50 60 fields s adjustable PAL NTSC Network protocols Telnet RTP HTTP ARP TCP UDP IP ICMP DHCP IGMPv2 802 1x HTTPS IGMPv3 SNMPv2 UPnP Encryption TLS 1 0 SSL AES optional Alarm input 1 Non isolated closing contact TTL logic 5V nominal 40 VDC max DC coupled with 22 kOhm pull up to 3 3 Relay output 1 Maximum...

Страница 119: ... Data en 119 Bosch Security Systems Installation and Operation Manual AR18 10 B006 v1 1 2010 06 Weight 0 670 kg 1 477 lb SMB 1 289 kg 2 842 lb Operating temperature 20 C to 50 C 4 F to 122 F cold start 50 C 58 F with heater enabled ...

Страница 120: ... Camera AR18 10 B006 v1 1 2010 06 Installation and Operation Manual Bosch Security Systems 13 1 1 Dimensions Figure 13 1 Flush mount dimensions 57 6 2 27 57 6 2 27 158 6 22 39 5 1 56 85 3 35 33 3 1 31 66 5 2 62 1 2 1 4 7 7 95 3 7 mm in ...

Страница 121: ...mera Technical Data en 121 Bosch Security Systems Installation and Operation Manual AR18 10 B006 v1 1 2010 06 Figure 13 2 Surface mount dimensions 53 3 2 1 53 3 2 1 30 8 1 21 35 1 38 130 5 5 14 121 4 77 mm in 158 6 22 ...

Страница 122: ... Technical Data FlexiDome IP Camera AR18 10 B006 v1 1 2010 06 Installation and Operation Manual Bosch Security Systems 13 1 2 Accessories Contact your Bosch representative for the latest available accessories ...

Страница 123: ...accordingly A ARP Address Resolution Protocol a protocol for mapping MAC and IP addresses B Baud Unit of measure for the speed of data transmission bps Bits per second the actual data rate C CF CompactFlash interface standard for digital storage media amongst other things Used in computers in the form of CF cards digital cameras and Personal Digital Assistants PDA CIF Common Intermediate Format vi...

Страница 124: ...he order in which intra frames and inter frames are arranged H H 264 Standard for high efficiency video compression based on the predecessors MPEG 1 MPEG 2 and MPEG 4 H 264 typically achieves a coding efficiency around three times as high as MPEG 2 This means that comparable quality can be achieved at around a third of MPEG 2 data quantity HTTP Hypertext Transfer Protocol protocol for transmitting...

Страница 125: ... Computer System Interface Protocol that manages storage via a TCP IP network iSCSI enables access to stored data from everywhere in the network ISDN Integrated Services Digital Network Comprised of digital telephony and data transport services offered by regional telephone carriers ISDN involves the digitization of the telephone network which permits voice data text graphics music video and other...

Страница 126: ...figure for the user data in a data packet N Net mask A mask that explains which part of an IP address is the network address and which part is the host address It is usually written in dotted decimal notation for example 255 255 255 192 NTP Network Time Protocol a standard for synchronizing computer system clocks via packet based communication networks NTP uses the connectionless network protocol ...

Страница 127: ...d service purposes for camera and DVR products RTP Realtime Transport Protocol a transfer protocol for real time video and audio S SFP Small Form factor Pluggable small standardized module for network connections designed as a plug connector for high speed network connections SNIA Storage Networking Industry Association association of companies for defining the iSCSI standard SNMP Simple Network M...

Страница 128: ... packet in station transfers U UDP User Datagram Protocol One of the core protocols of the Internet Protocol suite URL Uniform Resource Locator Previously Universal Resource Locator The unique address for a file that is accessible on the Internet UTP Unshielded Twisted Pair A variant of twisted pair cabling UTP cable is not surrounded by any shielding W WAN Wide Area Network A long distance link u...

Страница 129: ......

Страница 130: ...Bosch Security Systems www boschsecurity com Bosch Security Systems 2010 ...