46
en | Connections
MIC IP starlight 7000i
2019-11 | 2.1 |
Installation Manual
Bosch Security Systems
!
Caution!
Compliance with EN50130-4 Alarm Standard – CCTV for Security Applications
To meet the requirements of the EN50130-4 Alarm Standard, an ancillary uninterruptable
power (UPS) supply is necessary. The UPS must have a
Transfer Time
between 2–6 ms and a
Backup Runtime
of greater than 5 seconds for the power level as specified on the product
datasheet.
11.3
Ethernet Connections
!
Caution!
Ethernet cables must be routed through earth-grounded conduit capable of withstanding the
outdoor environment.
Cable Type
Cat5e/Cat6 Shielded Twisted Pair (STP) Ethernet (directly to the
camera, or to a network switch between the camera and the network)
Note
: Cat5e/Cat6 Shielded Twisted Pair (STP) cable is required in
order to meet European regulatory EMC standards.
Maximum Distance
100 m (330 ft)
Ethernet
10BASE-T/100BASE-TX, auto-sensing, half/full duplex
Terminal Connector
RJ45, Male
High PoE
For models with attached illuminators: Use the 95 W midspan sold by
Bosch.
For models
without
illuminators: Use the 60 W midspan sold by Bosch,
or a midspan that is compliant to the IEEE 802.3at, class 4 standard.
Note
: Consult the National Electrical Code (NEC) or other regional standards for cable
bundling requirements and limitations.
11.4
Camera Connections
All electrical and data connections from the camera are made from the connectors in the base
of the camera.