11.3
Ethernet Connections
!
Caution!
Ethernet cables must be routed through earth-grounded conduit capable of withstanding the
outdoor environment.
Cable Type
Cat5e/Cat6 Shielded Twisted Pair (STP) Ethernet (directly to the
camera, or to a network switch between the camera and the network)
Note
: Cat5e/Cat6 Shielded Twisted Pair (STP) cable is required in
order to meet European regulatory EMC standards.
Maximum Distance
100 m (330 ft)
Ethernet
10BASE-T/100BASE-TX, auto-sensing, half/full duplex
Terminal Connector
RJ45, Male
High PoE (95 W)
Use a midspan sold by Bosch, or a midspan that is offered as a
compatible alternative.
Note
: Consult the National Electrical Code (NEC) or other regional standards for cable
bundling requirements and limitations.