Bosch MADI Card Plus Series Скачать руководство пользователя страница 1

MADI Card Plus

Multichannel Audio Digital Interface Card

User Manual

93507896000 Rev B

08/2010

MADI

Back Card

MADI

Front Card

Содержание MADI Card Plus Series

Страница 1: ...MADI Card Plus Multichannel Audio Digital Interface Card User Manual 93507896000 Rev B 08 2010 MADI Back Card MADI Front Card ...

Страница 2: ...n permission from Bosch is prohibited WARRANTY AND SERVICE INFORMATION For warranty and service information refer to the appropriate web site below RTS www rtsintercoms com warranty RTSTW www rtstw com warranty AudioCom www telexaudiocom com warranty RadioCom www telexradiocom com warranty Headsets www intercomheadsets com warranty CUSTOMER SUPPORT Technical questions should be directed to Custome...

Страница 3: ...Card F01U169844 MADI 48 Card F01U169845 MADI 64 Card F01U169846 MADI 16 to 32 Upgrade F01U169847 MADI 16 to 48 Upgrade F01U169848 MADI 16 to 64 Upgrade F01U169849 MADI 32 to 48 Upgrade F01U169850 MADI 32 to 64 Upgrade F01U169851 MADI 48 to 64 Upgrade F01U169852 ...

Страница 4: ......

Страница 5: ...3 INSTALLATION 15 Requirements 15 How to Install 15 Card Installation 15 Cable the System 16 Configure your MADI 16 Plus Card 16 WINDOW DESCRIPTIONS 17 MADI Card Configuration Window 17 Slot Display Column 17 Description Display Column 18 Ports Display Column 1 18 Ports Display Column 2 18 Type Display Column 18 Reference Clock Drop Down Column 18 Sample Rate Drop Down Column 19 of Channels Drop D...

Страница 6: ...mn 23 Backup Link Display Column 23 Status Display Column 23 Pass Through Display Column 23 MADI to Serial Display Column 23 Serial to MADI Display Column 23 CONFIGURATION 25 Channel Allocation Scheme 25 Base 8 25 Base 16 26 Reference Clock 28 Sample Rate 29 Channel Size 30 Channel Mapping 31 Merge Channels 35 Download Firmware 36 Download License File to MADI Card 37 PORT ALLOCATION TABLE 39 Intr...

Страница 7: ...w 22 FIGURE 15 Base 16 Port Numbering Scheme Example 26 FIGURE 16 Base 8 Channel Number Scheme Example 26 FIGURE 17 Base Sixteen Check Box 27 FIGURE 18 Reference Drop Down Menu 28 FIGURE 19 Sample Rate Drop Down Menu 29 FIGURE 20 Channels Drop Down Menu 30 FIGURE 21 Channel Mapping Page 31 FIGURE 22 MADI Device Channel Menu 32 FIGURE 23 Channel Mapping Page 33 FIGURE 24 MADI Device Channel Ranges ...

Страница 8: ......

Страница 9: ...ith a range up to 9 32 miles 15km between ADAM frames Features Installation The MADI 16 Plus is hot swappable and installs in any available slot in an ADAM Intercom System It has an RJ 45 connection for an RS 232 or RS 485 pass thru serial port Scalability Provides 16 to 64 individually addressable audio channels Each initial MADI card has 16 channels with additional channels available for purchas...

Страница 10: ... Fiber A Link Fault Fiber B 20 Using Fiber B Link Fault Coax 19 Using Coax PLL Unlocked 18 PLL Locked Invalid Error Back Card 17 Valid Back Card FPGA Booted Driving Clock 16 Clock Good 15 14 13 Pass Through RS 485 12 Pass Through RS 232 Pass Through MADI to Serial Data Transferred 11 Pass Through Serial to MADI Data Transferred 10 Ctrl Bus RX Byte 9 Ctrl Bus RX Message 8 Acquired Ctrl Bus 7 6 5 4 ...

Страница 11: ...5 Reference Views FIGURE 1 MADI 16 Plus Back Card Reference View ...

Страница 12: ... it might be necessary to comply with higher class laser control measures during the service repair procedure Class 1 includes lasers that were formerly classified as Class 2a Power Input Power 5 2Amps 5V MADI Front Back Card Combined Power Consumption 26W Audio Performance THD N at 1KHz 0 4 Frequency Response within 1dB from 20Hz 20kHz Channel Support 56 Channels 64 Channels Connections Type Word...

Страница 13: ...7 Connection Pin Outs Connection Pin Outs RJ 45 Pin Outs RJ 45 PIN Function 1 TXD RS 232 Received Data or RS 485 2 RXD RS 232 Transmitted Data or RS 485 3 GND 4 N A 5 N A 6 N A 7 N A 8 N A ...

Страница 14: ...ch Position 8 Debug Only Mode Must be left in off position 7 Debug Only Mode Must be left in off position 6 n a Must be left in off position 5 n a Must be left in off position 4 n a Must be left in off position 3 n a Must be left in off position 2 n a Must be left in off position 1 n a Must be left in off position ...

Страница 15: ...witch Back Card DIP Switch FIGURE 3 Back Card DIP Switch Location DIP Switch Description Switch Position 1 Selects either RS 485 or RS 232 for the serial pass through port Off default RS 485 On RS 232 2 n a 3 n a 4 n a ...

Страница 16: ...10 System Configuration Schemes System Configuration Schemes Word Clock Configuration FIGURE 4 3 Card Word Clock Daisy Chain Wiring FIGURE 5 3 Card Word Clock Hub Wiring ...

Страница 17: ...11 System Configuration Schemes Fiber Configuration Coaxial Configuration FIGURE 6 3 Card Fiber Module A and Module B Wiring FIGURE 7 3 Card Coaxial Wiring ...

Страница 18: ...12 System Configuration Schemes TV Sync Configuration Serial Pass Through Configuration FIGURE 8 3 Card TV Sync Hub Wiring FIGURE 9 Serial Pass Through Wiring ...

Страница 19: ...13 System Configuration Schemes Trunking Configuration FIGURE 10 MADI 16 Plus Trunking Configuration ...

Страница 20: ...14 System Configuration Schemes ...

Страница 21: ...ll the MADI 16 Plus front and back card do the following 1 Gently insert the MADI 16 Plus front card into the front of the ADAM frame 2 Tighten the MADI 16 Plus front card CAUTION Do not fully tighten the front card into the frame 3 From the back of the ADAM frame insert the back card aligning it with the front card 4 Ensure the back card is properly seated against the MADI 16 Plus front card and ...

Страница 22: ... 16 Plus Card do the following Step 1 Select your Channel Allocation Scheme see Channel Allocation Scheme on page 25 Step 2 Set the Reference Clock for the MADI 16 Plus see Reference Clock on page 28 Step 3 Set the Sampling Rate for the MADI 16 Plus see Sample Rate on page 29 Step 4 Set the Channel Size for the MADI 16 Plus see Channel Size on page 30 Step 5 Map the channels of your MADI 16 Plus s...

Страница 23: ...play column shows the location of the card in relation to the frame the card resides and its position in the frame For example 2 017 indicates the card is in frame two 2 and slot 17 of the card in the frame The MADI 16 Plus can be put in any slot in the frame FIGURE 11 MADI Card Configuration Page ...

Страница 24: ...shows the ports assigned to the card Ports Display Column 2 The Ports display column shows the ports assigned to the card Type Display Column The Type display column shows the type of card in the slot for example MADI 16 AIO 16 etc Reference Clock Drop Down Column The Reference Clock drop down column is used to select the type of clock the MADI card uses to synchronize its transmissions Available ...

Страница 25: ...nd 64 Link Mode Drop Down Column The Link Mode drop down column is used to select the connector you want use For connector locations see Figure 1 on page 5 NOTE Redundancy is only supported between singular point to point connections Available selections for this field are Fiber A The signal is sent over the Fiber A connection Fiber B The signal is sent over the Fiber B connection Fiber A and B Th...

Страница 26: ...lect the card you want to configure Show MADI Cards Only Check Box The Show MADI Cards Only check box indicates to only show MADI cards in the Card Slot drop down list The default is to display all cards in the system Entry Display Column The Entry display column displays the number of audio channels you have available to use for the selected MADI card Port Display Column The Port display column s...

Страница 27: ...is used to select the MADI channel associated with the intercom port You can have up to 64 channels to choose from Available selections for this field are hyphen No channels are assigned Channels 1 64 Muted Check Box Column The Muted check box column is used to mute the transmit and receive channel audio By default Muted is not selected Show Unavailable Channels Check Box The Show Unavailable Chan...

Страница 28: ...lumn shows the first eight 8 channels assigned to the slot REFERENCE For more information on channel numbering schemes see Channel Allocation Scheme on page 25 Ports Display Column 2 The Ports display column shows the second eight 8 channels assigned to the slot REFERENCE For more information on channel numbering schemes see Channel Allocation Scheme on page 25 Type Display Column The Type display...

Страница 29: ...ibilities OK and Bad Status Display Column The Status display column shows status of the MADI card in the slot There are four 4 status message possibilities OK Wrong Back Card The wrong back card is installed FPGA Boot Failure PLL Unlocked Pass Through Display Column The Pass Through display column shows type pass through connection being used Available selections for this field are RS 232 and RS ...

Страница 30: ...24 MADI Card Status Window ...

Страница 31: ...ction there are two 2 configuration options that are supported by the MADI 16 Plus Base 8 standard density and Base 16 high density By default the channel allocation scheme is set to Base 8 Base 8 The Base 8 channel numbering system splits 16 channels between a top and bottom group The bottom group starts with channels 1 136 the top group consists of channels 137 272 see Figure 15 EXAMPLE If you h...

Страница 32: ...he Base 16 channel numbering scheme puts all 16 channels in one 1 slot This means when you configure your intercom system to support Base 16 slot 1 in the ADAM holds channels 1 16 slot 2 holds channels 17 32 slot 3 holds 33 through 48 and so on FIGURE 15 Base 8 Channel Number Scheme Example FIGURE 16 Base 16 Port Numbering Scheme Example ...

Страница 33: ...tions menu in AZedit select Frame Mapping Table The Frame Mapping Table window appears 2 Clear the Base 16 check box for the frame you want Base 8 channel configuration OR Select the Base 16 check box for the frame you want Base 16 channel configuration FIGURE 17 Base Sixteen Check Box ...

Страница 34: ...is set by the NTSC PAL TV Sync source Word Clock The MADI stream is set by the Word Clock To set the reference clock do the following 1 From the System menu in AZedit select Miscellaneous MADI Configuration The MADI Configuration window appears 2 On the MADI configuration tab find the MADI card you are configuring 3 From the Reference Clock column drop down menu select the Reference Clock Source y...

Страница 35: ...wing 1 From the System menu in AZedit select Miscellaneous MADI Configuration The MADI Configuration window appears 2 On the MADI configuration tab find the MADI card you are configuring 3 From the Sample Rate column drop down menu select the sample rate you want to use 4 Send the changes to the Matrix FIGURE 19 Sample Rate Drop Down Menu ...

Страница 36: ...the MADI channels correctly To set the channel size do the following 1 From the System menu in AZedit select Miscellaneous MADI Configuration The MADI Configuration window appears 2 On the MADI configuration tab find the MADI card you are configuring 3 From the Channels column drop down menu select the channel size of the MADI device you are using 4 Send the changes to the Matrix FIGURE 20 Channel...

Страница 37: ... MADI Configuration The MADI Configuration window appears 2 Click the MADI Channel Mapping tab The MADI Channel Mapping page appears 3 From the Card Slot drop down menu select the MADI 16 Plus card you want to assign a MADI device channel NOTE If you are using multiple types of cards i e RVON 16 AIO 16 etc in your frame select the Show MADI cards only check box to only show MADI cards This makes i...

Страница 38: ... the Channel drop down menu A list of available MADI device channels appear 6 Select the MADI device channel you want to assign 7 Click the activate icon to send the assignment to the matrix FIGURE 22 MADI Device Channel Menu ...

Страница 39: ...in your frame select the Show MADI cards only check box to only show MADI cards This makes it easier for you to select the card you want to assign channels to 4 From the MADI Channel column select the device channels you want to assign to the MADI 16 Card NOTE To select random channels hold the Ctrl key down on the keyboard and click the individual channels you want to assign The channels you sele...

Страница 40: ...e Channel drop down menu A list of available channel ranges appear 6 Select the channel range you want to assign 7 Click the activate icon to send the assignment to the matrix FIGURE 24 MADI Device Channel Ranges ...

Страница 41: ...o path for the channels is as follows EXAMPLE Device 1 sends eight 8 channels MADI channels 1 8 to the MADI card 2 The MADI card sends eight 8 more channels MADI channels 9 16 to Device 3 Device 3 takes and replaces all 16 channels and sends those 16 channels to Device 1 When Device 1 receives the 16 MADI channels it takes its eight 8 channels 1 8 and replaces them with new data and passes the 16 ...

Страница 42: ...ars NOTE To select multiple MADI 16 Plus cards hold down the Ctrl key while you click the MADI cards 3 Select Download Firmware The Download Firmware window appears 4 Navigate to the hex file you want to download 5 Click Open The Download Device Firmware window appears 6 Click Begin Download The download begins This takes a minute or two to occur A success message appears when the download is fini...

Страница 43: ...Plus card from the frame until you have verified the new version information from AZedit If the card loses power during download undesirable results may occur Download License File to MADI Card To download the license file do the following 1 From the I O Version window right click the MADI card you want to upgrade A popup menu appears 2 From the popup menu select Download license The License Downl...

Страница 44: ... File window appears 5 Click Begin The license file is downloaded A success message appears once the file is done downloading 6 From the Status menu select I O Card Status The I O Card Status window appears 7 Verify the download was successful FIGURE 30 Download License File Window ...

Страница 45: ...d NOTE If you are running a single frame system the single frame can hold up to 880 ports if you are running a multi frame Tribus system you are limited to 256 ports per frame IMPORTANT Check power limitations of each frame before building large intercom systems Requirements The Port Allocation Table requires the following minimum firmware versions AZedit V3 9 0 MCII e V2 3 0 DBX V1 24 0 w PCII e ...

Страница 46: ...rd resides This field is not editable Type Column The Type column is used to select the type of card in the slot Use the drop down menu to select the type of card in the slot Available options are AIO 8 AIO 16 RVON 8 RVON 16 MADI 16 MADI 32 MADI 48 MADI 64 and AES 3 FIGURE 31 Port Allocation Table Window FIGURE 32 Type Column Options ...

Страница 47: ... in a Base 8 system 8 8 Used to allocate 16 ports in a Base 8 system 16 Used to allocate 16 ports in a Base 16 system 24 Used to allocate 24 ports in a Base 16 system 32 Used to allocate 32 ports in a Base 16 system 40 Used to allocate 40 ports in a Base 16 system 48 Used to allocate 48 ports in a Base 16 system 56 Used to allocate 56 ports in a Base 16 system 64 Used to allocate 64 ports in a Bas...

Страница 48: ...tion debug assign consecutive port numbers for multi group port columns NOTE The Ports column only becomes active for the number of ports you are allocating For example if you have 32 ports only the first two 2 Ports columns are enabled Warning Column The Warning column displays a warning when configured card types do not match detected card types and when not all ports are allocated for a given c...

Страница 49: ...stem while the window remains open Test Button The Test button is used to test the modifications you made to the port allocation table before you apply it to the intercom system A message displays when the test is finished notifying you if the port allocation table is valid or not Cancel Button The Cancel button is used to close the window without implementing any of the modifications made to the ...

Страница 50: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com ...

Отзывы: