1

UNPACKING

Unpack carefully. This is electronic equipment and
should be handled carefully.

Check for the following items:

Verify the model no. of unit.

If an item appears to have been damaged in shipment,
replace it properly in its carton and notify the shipper.
If any items are missing, notify your Bosch Security
Systems Inc. Sales Representative or Customer Service.

The shipping carton is the safest container in which the
unit may be transported. Save it for possible future use.

2

SERVICE

If the unit ever needs repair service, the customer
should contact the nearest Bosch Security Systems Inc.
Service Center for authorization to return and shipping
instructions.

Service Centers

USA

Phone:

800-366-2283 or 717-735-6638

fax:

800-366-1329 or 717-735-6639

CCTV Spare Parts

Phone:

800-894-5215 or 408-956-3853 or 3854

fax:

408-957-3198

e-mail:

[email protected]

Canada

Phone:

514-738-2434

Europe, Middle East & Asia Pacific Region

Phone:

32-1-440-0711

For additional information, see
www.boschsecuritysystems.com.

3

DESCRIPTION

The LTC 5121/60, LTC 5121/50, LTC 5141/60 and 
LTC 5141/50 are automatic sequential video switchers.
The LTC 5121/60 and LTC 5121/50 have 2-camera
inputs and 1-monitor output; the LTC 5141/60 and
LTC 5141/50 have 4-camera inputs and 1-monitor
output.

4

INSTALLATION

4.1

Power

LTC 5121/60 and LTC 5141/60 models operate 
from 120VAC, 50/60Hz power. LTC 5121/50 and 
LTC 5141/50 models operate from 220-240VAC,
50/60Hz power. The model number and operating
voltage are shown on the label located on the bottom
of the unit. These units are supplied with ground
power cords; grounding should not be defeated.

4.2

Mounting

These switchers are supplied as desk-top units. For rack
mounting, the LTC 9101/00 rack-mount kit is available.

4.3

Video Inputs

The LTC 5121/60 and LTC 5121/50 both have two
video inputs labeled 

CAM 1

and 

CAM 2

. The 

LTC 5141/60 and LTC 5141/50 both have four video
inputs labeled 

CAM 1

CAM 2

CAM 3

, and 

CAM 4

.

The LTC 5141/60 and LTC 5141/50 incorporate an
auto-skip feature on CAM 3 and CAM 4. If video is
not supplied to video input 4, the unit will skip over
CAM 4 when sequencing (

run

mode). If video is not

supplied to video input 3, the unit will skip over 
CAM 3 and CAM 4 when sequencing. When using
only 3 video inputs, use inputs CAM 1, CAM 2, and
CAM 3. When using only 2 video inputs, use inputs
CAM 1 and CAM 2.

All video inputs are 75

terminated.

4.4

Monitor Output

The monitor output is designed to 

look

into a 75

load. Therefore, if you loop the monitor output line
through monitors or other equipment, be sure their
terminations are set to Hi-Z. Only the last unit on the
line should have its termination set to 75

.

Содержание LTC 5121 Series

Страница 1: ...LTC 5121 LTC 5141 Series Instruction Manual EN 2 and 4 Position Economical Sequential Switcher ...

Страница 2: ...trical shock or other hazards 9 Safety Check Upon completion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition 10 Power Sources Operate the unit only from the type of power source indicated on the label If unsure of the type of power supply to use contact your dealer or local power company For units intended to operate from...

Страница 3: ...lation or rack unless proper ventilation is provided or the manufacturer s instructions have been adhered to The equipment must not exceed its maximum operating temperature requirements 2 Mechanical Loading Mounting of the equipment in a rack shall be such that a hazardous condition is not achieved due to uneven mechanical loading WARNING Electrostatic sensitive device Use proper CMOS MOSFET handl...

Страница 4: ...ica siempre que el cable de alimentación esté conectado a la fuente de alimentación Sin embargo la unidad sólo funciona cuando el interruptor está en la posición de encendido El cable de alimentación es la principal fuente de desconexión de todas las unidades PRECAUCIÓN PARA DISMINUIR EL RIESGO DE DESCARGA ELÉCTRICA NO RETIRE LA CUBIERTA NI LA PARTE POSTERIOR NO EXISTEN PIEZAS DE RECAMBIO EN EL IN...

Страница 5: ...e del prodotto Ciò comporta un potenziale rischio di scosse elettriche Si consiglia di consultare le istruzioni operative e di manutenzione interventi tecnici contenute nella documentazione fornita con il dispositivo Medidas de Segurança Atenção a instalação deve ser executada apenas por técnicos qualificados da assistência de acordo com o código eléctrico nacional ou os códigos locais aplicáveis ...

Страница 6: ...eguards 2 FCC Information 4 1 UNPACKING 7 2 SERVICE 7 3 DESCRIPTION 7 4 INSTALLATION 7 4 1 Power 7 4 2 Mounting 7 4 3 Video Inputs 7 4 4 Monitor Output 7 5 OPERATION 8 5 1 RUN Button and Indicator 8 5 2 DWELL Control 8 5 3 Camera Buttons and Indicators 8 6 ILLUSTRATIONS 8 6 1 LTC 5121 60 LTC 5121 50 8 6 2 LTC 5141 60 LTC 5141 50 9 ...

Страница 7: ...d 1 monitor output the LTC 5141 60 and LTC 5141 50 have 4 camera inputs and 1 monitor output 4 INSTALLATION 4 1 Power LTC 5121 60 and LTC 5141 60 models operate from 120VAC 50 60Hz power LTC 5121 50 and LTC 5141 50 models operate from 220 240VAC 50 60Hz power The model number and operating voltage are shown on the label located on the bottom of the unit These units are supplied with ground power c...

Страница 8: ...time Rotating the control counter clockwise causes the switcher to sequence faster decreases the dwell time The dwell time is approximately 2 seconds when the control is turned fully counter clockwise full clockwise rotation of the control provides a dwell time of approximately 45 seconds 5 3 Camera Buttons and Indicators These buttons are used to call up a camera and stop automatic sequencing Whe...

Страница 9: ...Bosch Security Systems 13 February 2004 6 2 LTC 5141 60 LTC 5141 50 LTC 5121 LTC 5141 Instruction Manual Illustrations EN 9 Figure 2 Front and Back Panels Figure 3 Typical Installation ...

Страница 10: ...Bosch Security Systems 13 February 2004 LTC 5121 LTC 5141 Instruction Manual EN 10 ...

Страница 11: ...Bosch Security Systems 13 February 2004 LTC 5121 LTC 5141 Instruction Manual EN 11 ...

Страница 12: ...curity Systems Inc 850 Greenfield Road Lancaster PA 17601 USA Tel 800 326 3270 Fax 1 717 735 6560 www boschsecuritysystems com Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Tele 31 40 27 80000 Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Republic of Singapore Tel 65 6 319 3486 ...

Отзывы: