2 610 A12 917 | (19.1.10)
Bosch Power Tools
24
| English
Assembly
Inserting/Replacing the Battery
Alkali-manganese batteries are recommended for the measuring tool.
Press the latch
9
of the battery lid outward and open the battery
lid
11
.
When inserting the battery, pay attention to the correct polarity ac-
cording to the representation on the inside of the battery compart-
ment.
When the battery indication
c
appears for the first time on the dis-
play
7
, the measuring tool can still be operated for approx. 3 h.
f
If the measuring tool is not used for a long period of time, the
battery must be removed.
The battery can corrode or discharge
itself over long periods.
Operation
Initial Operation
f
Protect the measuring tool against moisture and direct sun
light.
f
Do not subject the measuring tool to extreme temperatures or
variations in temperature.
As an example, do not leave it in ve-
hicles for longer periods. In case of large variations in tempera-
ture, allow the measuring tool to adjust to the ambient temper-
ature before putting it into operation. In case of extreme
temperatures or variations in temperature, the accuracy of the
measuring tool can be impaired.
Position the measuring tool at least 50 cm away from the rotational
laser level. Position the measuring tool in such a manner that the
laser beam can reach the reception area
6
. Set the highest rotation-
al speed on the rotational laser level.
OBJ_BUCH-780-003.book Page 24 Tuesday, January 19, 2010 10:56 AM