Installation and connection
en
5
5
Installation and
connection
Installation and connection
Scope of supply
After unpacking all parts, check for any damage in
transit.
If you have any complaints, contact the dealer from
whom you purchased the appliance or our Customer
Service.
The delivery consists of the following parts:
■
Free-standing appliance
■
Interior fittings (depending on model)
■
User manual
■
Customer service booklet
■
Warranty enclosure
■
Information on the energy consumption and noises
Technical specifications
Refrigerant, cubic capacity and further technical
specifications can be found on the rating plate.
"Getting to know your appliance" on page 13
Installing the appliance
Installation location
The more refrigerant an appliance contains, the larger
the room in which the appliance is situated must be. In
rooms which are too small, leaking refrigerant can form
a flammable gas-air mixture.
At least 1 m³ of room space is required per 8 g of
refrigerant. The amount of refrigerant in your appliance
is indicated on the rating plate inside the appliance.
"Getting to know your appliance" on page 13
The weight of the appliance may be up to 180 kg
depending on the model. The base must be sufficiently
stable, and should not give. If necessary, reinforce the
floor.
Permitted room temperature
The permitted room temperature depends on the
climate class of the appliance.
Information on the climate class can be found on the
rating plate.
"Getting to know your appliance" on page 13
The appliance is fully functional within the permitted
room temperature.
If an appliance with climate class SN is operated at
colder room temperatures, the appliance will not be
damaged up to a room temperature of +5 °C.
Climate class
Permitted room temperature
SN
50 °F ... 90 °F (+10 °C ... 32 °C)
N
61 °F ... 90 °F (+16 °C ... 32 °C)
ST
61 °F ... 100 °F (+16 °C ... 38 °C)
T
61 °F ... 110 °F (+16 °C ... 43 °C)