background image

 

 

Wireless Local Security Network 

wLSN

Release Notes 

October 2006

1.0 Compatibility 

wLSN is compatible with the Easy Series V2+ 
Intrusion Control Panel. 

2.0 Known 

Issues 

2.1 General 

Information 

 

 

CAUTION:

 If you have unused wireless 

devices, replace the battery tabs or 
remove the batteries to prevent battery 
depletion. 

 

 

Returning a Device to an Undiscovered State: 

In the wLSN Reference Guide (P/N: F01U009440), 
Section 2.4 Site Testing explains how to return a 
device to the undiscovered state. This explanation 
is incorrect. Below is the correct procedure: 
1.

 

Remove the batteries. 

2.

 

Press and hold the tamper switch button. 

3.

 

Reinsert the batteries while holding the 
tamper switch button. 
The device’s LED turns on. 

4.

 

Release the tamper switch button within five 
sec. after the device’s LED turns on. 
The device returns to an undiscovered state. 

 

Magnet Placement for Door-Window Contact, 
Mini Door-Window Contact, and Inertia 
Detector:

 The magnet can be placed on either 

side of these devices.

 

2.2 

Mini Door-Window Contact 
(ISW-BMC1-M82X) 

Tamper Switch Location:

 Refer to Figure 1 for the 

location of the tamper switch on the Mini Door-
Window Contact. 

 

Figure 1: Tamper Switch Location  

 

2.3 

Recessed Door-Window Contact 
(ISW-BMC1-R135X) 

Tamper Switch Location:

 Refer to Figure 2 for the 

location of the tamper switch on the Recessed Door-
Window Contact. 

 

Figure 2: Tamper Switch Location 

 

 

2.4 Glassbreak 

Detector 

(ISW-BGB1-SAX) 

 

RF Signal Strength (RFSS) Mode LED 
Location: 

Refer to Figure 3 for the location of the 

LED that turns on when the detector enters RFSS 
Mode. 

 

Figure 3: RFSS Mode LED Location 

 

    