Appendix
21
Heat Radiator 4500 – 6720883002 (2019/10)
9.3
Technical Data
Table 8 Specifications of heater rod
9.4
Location of heater rod in relation to radiator
Table 9 Location of heater rod in relation to radiator
9.5
Product data for energy consumption
The following product data satisfy the requirements of the EU Regulation No. 813/2013 supplementing Directive 2010/30/EU.
Table 10 Product data for energy consumption
Unit
Heat Radiator 4500
Operating voltage
KW
230 V AC ± 10 % 50 Hz
Rated output of heater rod
(
W
500, 600, 750, 900,
1000
Maximum breaking capacity of the
control unit
W
1500
IP rating/protection class
IP
44/II
Connection cable
–
Spiral cable 0.5 m
(extended 2.0 m), Plug
design: UNI-SCHUKO
Temperature setting range
°C
7 ... 32
Time period of the dry mode
h
2
Connection thread (ISO 228)
"
G 1/2
Max. operating pressure
bar/MPa
10/1.0
Installation position
–
Vertically with control
unit at the bottom
H x W [mm]
=
P [W]
1110 × 500
=
500
1110 × 600
=
600
1420 × 500
=
750
1420 × 600
=
900
1700 × 500
=
900
1700 × 600
=
1000
8
... 19
Product data
Symbol
Unit
Heat Radiator 4500
Heat output
Specified heat output
P
rated
KW
0.5/0.6/0.9/1.0
Minimum heat output (indicative)
P
min
KW
0.45/0.54/0.875/0.9
Maximum continuous output
P
max, c
KW
0.525/0.630/0.93/1.05
Auxiliary electricity consumption
For rated heat output
el
max
KW
0.00095
At minimum heat output
el
min
KW
0.00095
In standby mode
el
sb
KW
0.00042
Type of heat transfer/room temperature-dependent control
Electronic room temperature-dependent control with week timer
–
–
Yes
Other control options
Room temperature-dependent control with presence detection
–
–
No
Room temperature-dependent control with open-window detection function
–
–
Yes
Room temperature-dependent control with remote control option
–
–
No
Room temperature-dependent control with adaptive control of heating start
–
–
No
Room temperature-dependent control with operating time limit
–
–
No
Room temperature-dependent control with black ball sensor
–
–
No