12
| English
data. This may take several minutes. Press the right-
hand arrow button
(10)
for
<More>
to enter this sub-
menu. Then press either the right-hand function
button
(9)
to delete all files, or the left-hand function
button
(16)
to cancel.
You can also press the measuring button
(22)
to exit any
menu and return to the home screen.
Documenting Measurements
Saving Measurements
The measuring tool begins to take measurements as soon as
it is switched on and does so continuously until it is switched
off.
To save an image, point the camera at the required measur-
ing object and press the "Save" button
(13)
. The image is
saved in the internal memory of the measuring tool. Alternat-
ively, press the measuring button
(22)
(pause). The meas-
urement is frozen and shown in the display. This enables you
to carefully view the image and to make retrospective adjust-
ments (e.g. to the colour palette). If you do not wish to save
the frozen image, restart measuring mode by pressing the
measuring button
(22)
. If you wish to save the image in the
internal memory of the measuring tool, press the "Save"
button
(13)
.
Recording a Voice Note
You can record a voice note to keep a record of environ-
mental conditions or additional information about the saved
thermal image. This information is saved in addition to the
thermal image and visual image and can be transferred at a
later stage.
It is recommended that you record a voice note in order to
keep better documentation.
The voice note is recorded in the gallery. Proceed as follows:
– To access the gallery, press the left-hand function
button
(16)
.
– Press the
Func
(8)
button. The recording will start. Re-
cord all the relevant information.
– To
end
the recording, either press the
Func
(8)
button
again or press the right-hand function button
(9)
.
– To
cancel
the recording, press the left-hand function
button
(16)
. After you have made the recording, you will
be able to listen to the voice note.
– To
listen back
to the recording, press the
Func
(8)
but-
ton again. The recording will be played back.
▪
To
pause
playback, press the right-hand function
button
(9)
. To continue playing the paused recording,
press the right-hand function button
(9)
again.
▪
To
stop
playback, press the left-hand function
button
(16)
.
To record a new voice note, delete the current voice note
and then start a new recording.
When recording, please note the following:
– The microphone
(15)
is located behind the keyboard next
to the microphone symbol. Speak in the direction of the
microphone.
– The recording can last a maximum of 30 seconds.
Calling Up Saved Images
Proceed as follows to call up saved thermal images:
– Press the left-hand function button
(16)
. The most re-
cently saved photo now appears in the display.
– Press the right-hand
(10)
or left-hand
(14)
arrow button
to switch between the saved thermal images.
The visual image has been saved alongside the thermal im-
age. To call up the visual image, press the down arrow
button
(12)
.
You can also display the thermal image taken as a full-screen
image by pressing on the up arrow button
(7)
. In the full-
screen view, the title bar is hidden after 3 seconds so that
you can see all the details of the thermal image.
You can use the up arrow button
(7)
and the down arrow
button
(12)
to switch between views.
Deleting Saved Images and Voice Notes
Switch to the gallery view to delete individual or all thermal
images:
– Press the right-hand function button
(9)
under the waste
paper basket symbol. A submenu will open. Here you can
select whether you want to delete only this image, only
the corresponding voice note (if you have recorded one)
or all images. If you want to delete only this image or the
voice note, confirm the process by pressing the
Func
(8)
button.
– If you want you delete all images, press the
Func
(8)
but-
ton or the right-hand function button
(9)
; you can also
confirm the process by pressing the right-hand function
button
(9)
or cancel the deletion by pressing the left-
hand function button
(16)
.
Data fragments of the images remain stored in the memory
and could be reconstructed. You can
select
<Tool>
→
<Factory settings>
in the main menu to
permanently delete.
Data Transfer
Data Transfer via USB Port
Open the flap for the USB Type-C® port
(5)
. Connect the
USB Type-C® port
(6)
of the measuring tool to your com-
puter via the USB Type-C® cable
(25)
provided.
Now press the on/off button
(11)
to switch on the measuring
tool.
Open the file browser on your computer and select the
GTC 600 C
drive. The saved files can be copied from the in-
ternal memory of the measuring tool, moved to your com-
puter or deleted.
As soon as you have finished the required operation, discon-
nect the drive from the computer following the standard pro-
cedure and then use the on/off button
(11)
to switch the
measuring tool off again.
Caution:
Always disconnect the drive from your operating
system first (eject drive), as failure to do so may damage the
internal memory of the measuring tool.
Remove the USB Type-C® cable
during
the measuring opera-
tion and close the flap
(5)
.
1 609 92A 58Z | (22.02.2021)
Bosch Power Tools