Operation instructions
51
Greentherm T9900 SE/i – 6 720 813 635 (2019/03)
▶ Touch the symbol
until the display shows
P9 Purge
.
After 2 sec. the fan starts working to purge the exhaust
circuit.
The fan remains running until the Purge menu is exited, to do
so:
▶ Touch the symbol
.
6.6
Service menu - AU Technical Settings
Accessing the AU Technical Settings menu
▶ Touch the symbol
.
Display shows
P4 Information
.
▶ Touch symbols
or
to select
AU Technical
Settings
menu.
▶ Touch the symbol
.
Display shows authentication menu (password input).
▶ The password is 1886.
Authentication completed.
▶ Touch the symbol
.
Access to
installer exclusive menus
.
•
P7 - Gas Type (LPG, NG)
•
LM - Temperature Limited
•
RS - Recirculation Settings
•
CA - Combustion Adjust
•
PA - Water Actuator
•
PF - Bypass Valve
•
PE - Appliance Type
•
AB - Region Selection
•
A4 - Demonstration
P7 Gas Type (LPG, NG)
For more information:
▶
LM Temperature Limited
Unlock the Temperature Limit
▶ Touch the symbol
.
Display shows following menu.
–
Unlocked
– Locked
The current selection is in green color.
▶ Touch symbols
or
to select
Unlocked
.
▶ Touch the symbol
.
▶ Touch the symbol
to return to main menu.
RS Recirculation Settings
To define recirculation comfort level,
▶ Touch the symbol
.
▶ Touch symbols
or
to define comfort level.
–
1
–
2
– ...
–
9
Choosing a higher comfort level (9) will set the recirculation
water temperature closer to the set point defined on the
water heater. Choosing a lower value (1) will favor
efficiency at the expense of recirculation temperature
comfort.
▶ Touch the symbol
.
▶ Touch the symbol
to return to main menu.
CA Combustion Adjust
For more information:
▶
PA Water Actuator
For more information:
▶
PF Bypass Activation
To Enable or Disable bypass function.
▶ Touch the symbol
.
Display shows following menu.
–
Off
– On
The current selection is in green color.
▶ Touch symbols
or
to select the desired option.
▶ Touch the symbol
.
▶ Touch the symbol
to return to main menu.
PE Appliance Type
This menu shows the technical specifications of the appliance.
•
AP Appliance Power
•
ML Model
•
TP Type
AP Appliance Power
▶ Touch the symbol
.
Display shows appliance power (default set).
–
199K BTU
or
–
160K BTU
▶ Touch the symbol
to exit.
▶ Touch symbols
or