background image

Gas Conversion Kit

1

6720813634 (2019/02) US

1

Gas Conversion

DANGER: 

Personal injury and property damage

▶ This conversion shall only be performed by a trained and 

certified installer in accordance with the manufacturer‘s 
instructions and all applicable codes and requirements of 
the authority having jurisdiction.

▶ If the information in these instructions is not followed 

exactly, or the installation, adjustment, modification, 
operation or maintenance is carried out by an unqualified 
person, a fire, explosion or generation of large amounts of 
carbon monoxide may result causing property damage, 
personal injury or loss of life.

▶ Always disconnect the appliance from the mains power 

before performing any work. Always disconnect the 
appliance from the mains power before performing any 
work. Take measures to prevent accidental reconnection.

▶ The installer is responsible for the proper conversion of this 

appliance.

▶ The conversion is not complete until the operation of the 

converted appliance is checked as specified in these 
instructions.

DANGER: 

Explosion!

▶ Close the gas cock prior to working on the gas train.
▶ Check for gas leaks after carrying out work on the gas train.

Installation, power connection, connection on the gas and flue 
gas side and commissioning must only be carried out by a 
contractor certified for such work by the state or local 
jurisdiction or the local gas or power utility.

2

Installation instructions

▶ Follow installation manual for more details, section 6 

Operation Instructions.

▶ Assemble the LP conversion kit.

Fig. 1  

LP conversion kit

▶ Disconnect the power supply cord and shut off the gas 

supply.

Fig. 2  

▶ Remove NG plate.

Fig. 3  

NG plate

▶ Install the LP conversion plate, as shown in fig. 4 and fig. 5, 

for the 160kBtu and 199kBtu appliance, respectively.

Fig. 4  

160kBTU appliance gas conversion kit

Содержание Greentherm 9000

Страница 1: ...easures to prevent accidental reconnection Theinstallerisresponsiblefortheproperconversionofthis appliance The conversion is not complete until the operation of the converted appliance is checked as specified in these instructions DANGER Explosion Close the gas cock prior to working on the gas train Check for gas leaks after carrying out work on the gas train Installation power connection connecti...

Страница 2: ...on the HMI P7 menu See installation manual for more details section 6 Fig 7 Change gas type Open a tap and check for gas leak Fig 8 Update TYPE OF GAS in the rating plate of the appliance using the label provided with the gas conversion kit Fig 9 ConfirmCO2andCOvalues section8 12COEmission If necessary adjustGasandAirflowparameters seechapter 8 11 for more information ...

Страница 3: ...irequalifiéestresponsabledelatransformation correcte de l appareil L installationestconformeetcomplèteuniquementlorsque le fonctionnement de l appareil transformé a été contrôlé comme décrit dans la présente notice DANGER Explosion Fermer le robinet de gaz avant de travailler sur les conduites de gaz Réaliser un contrôle d étanchéité après avoir effectuer des travaux sur des composants contenant d...

Страница 4: ... installation pour plus d informations cha pitre 6 Fig 16 Changer le type de gaz Ouvrir un robinet d eau chaude et contrôler l absence de fuites de gaz Fig 17 Mettre à jour le TYPE DE GAZ sur la plaque signalétique de l appareil en utilisant l étiquette fournie avec les plaques de conversion Fig 18 Confirmer les valeurs CO2 et CO chapitre 8 12 Si néces saire ajuster le débit de Gaz d Air voir chap...

Отзывы: