The radio devices can now be logged on.
3.
Remove the radio device from the base or housing.
The internal alarm indicator flashes briefly at 2-second intervals.
4.
Remove the base or housing.
5.
Remove the battery pack from the radio device.
6.
Store, transport, and dispose of the battery pack in accordance with local regulations and
laws.
The radio gateway registers the radio device as missing after a maximum of 5
minutes.
LED
(H4) flashes.
7.
When LED
(H4) flashes, press and hold button
(S1) for at least 2
seconds.
The radio cell switches to normal operation.
The radio gateway deletes the missing radio device from its memory.
8.
Follow the same steps to remove the next radio device. Start with step
2.
9.
Complete the work as instructed by the fire detection system documentation.
10. Make a note of the change in your documents.
P
The radio devices have now been removed.
7.4.4
Replacing a radio device with another of the same type
If you replace a radio device with another device of the same type, the ID of the new radio
device needs to be updated in the FSP-5000-RPS configuration.
If you want to replace multiple radio devices, you must finish
replacing one device before you start replacing the next one.
The site configuration needs to be updated.