background image

Camera Browser Interface

Bosch IP Cameras FW5

en

Software manual

Содержание FW5

Страница 1: ...Camera Browser Interface Bosch IP Cameras FW5 en Software manual ...

Страница 2: ......

Страница 3: ...13 2 2 Recordings 13 2 3 Settings 13 3 Operation via the browser 14 3 1 Livepage 14 3 1 1 Image selection 14 3 1 2 Status icons 15 3 1 3 View Control 16 3 1 4 Digital I O 17 3 1 5 System Log Event Log 17 3 1 6 Saving snapshots 18 3 1 7 Recording video sequences 18 3 1 8 Running recording program 18 3 1 9 Audio communication 19 3 1 10 Processor load 19 3 2 Recordings page 20 3 2 1 Controlling playb...

Страница 4: ...al Settings 31 7 1 Identification 31 7 1 1 ID 31 7 1 2 Naming 31 7 1 3 iSCSI Initiator extension 31 7 2 Password 32 7 2 1 Password 32 7 2 2 Confirm password 32 7 3 Date Time 33 7 3 1 Date format 33 7 3 2 Device date Device time 33 7 3 3 Device time zone 33 7 3 4 Daylight saving time 33 7 3 5 Time server IP address 34 7 3 6 Time server type 34 7 4 Display Stamping 35 7 4 1 Camera name stamping 35 7...

Страница 5: ... metadata 38 8 2 6 Show event log 38 8 2 7 Show system log 39 8 2 8 Allow snapshots 39 8 2 9 Allow local recording 39 8 2 10 Path for JPEG and video files 39 8 3 Logging 40 8 3 1 Save event log 40 8 3 2 Save system log 40 9 Camera 41 9 1 Installer Menu 41 9 1 1 Base frame rate 41 9 1 2 Mirror image 41 9 1 3 Flip image 41 9 1 4 Menu button 41 9 1 5 Heater dome cameras only 41 9 1 6 Restore all defa...

Страница 6: ... 5 Maximum bit rate 51 10 1 6 Encoding interval 51 10 1 7 Standard definition video resolution 51 10 1 8 Expert Settings 52 10 1 9 Default 52 10 2 Encoder Streams 53 10 2 1 H 264 settings 53 10 2 2 JPEG stream 54 11 Recording 55 11 1 Storage Management 56 11 1 1 Device manager 56 11 1 2 Recording media 56 11 1 3 Activating and configuring storage media 57 11 1 4 Formatting storage media 58 11 1 5 ...

Страница 7: ...nation password 66 12 1 5 Video transmission 67 12 1 6 Remote port 67 12 1 7 Video output 67 12 1 8 Decoder 68 12 1 9 SSL encryption 68 12 1 10 Auto connect 68 12 1 11 Audio 68 12 2 Video Content Analyses VCA 69 12 3 Audio Alarm 70 12 3 1 Audio alarm 70 12 3 2 Name 70 12 3 3 Signal Ranges 70 12 3 4 Threshold 70 12 3 5 Sensitivity 70 12 4 Alarm E Mail 71 12 4 1 Send alarm e mail 71 12 4 2 Mail serv...

Страница 8: ... Scheduled 81 13 3 1 Weekdays 81 13 3 2 Holidays 81 13 4 VCA Event triggered 83 13 4 1 Trigger 83 13 4 2 Trigger active 83 13 4 3 Trigger inactive 83 13 4 4 Delay s 83 14 Interfaces 84 14 1 Alarm input 84 14 1 1 Name 84 14 2 Relay 84 14 2 1 Idle state 84 14 2 2 Operating mode 84 14 2 3 Relay follows 84 14 2 4 Relay name 85 14 2 5 Trigger relay 85 14 3 COM1 85 14 3 1 Serial port function 85 14 3 2 ...

Страница 9: ... 1 10 Telnet support 88 15 1 11 Interface mode ETH 88 15 1 12 Network MSS Byte 88 15 1 13 iSCSI MSS Byte 88 15 1 14 Enable DynDNS 89 15 1 15 Host name 89 15 1 16 User name 89 15 1 17 Password 89 15 1 18 Force registration now 89 15 1 19 Status 89 15 2 Advanced 90 15 2 1 SNMP 90 15 2 2 1 SNMP host address 2 SNMP host address 90 15 2 3 SNMP traps 90 15 2 4 Authentication 802 1x 90 15 2 5 RTSP port 9...

Страница 10: ...AM18 Q0605 v5 0 2011 07 Software manual Bosch Security Systems 15 5 Encryption 95 16 Service 96 16 1 Maintenance 96 16 1 1 Firmware 96 16 1 2 Configuration 97 16 1 3 SSL certificate 97 16 1 4 Maintenance log 98 16 2 Licenses 98 16 3 System Overview 98 ...

Страница 11: ...using the browser 1 1 System requirements Network access Intranet or Internet Microsoft Internet Explorer version 7 0 or higher Screen resolution at least 1024 768 pixels 16 or 32 bit color depth Sun JVM installed The Web browser must be configured to enable Cookies from the IP address of the unit In Windows Vista deactivate protected mode on the Security tab under Internet Options To play back li...

Страница 12: ...o 25 web browser connections or up to 50 connections via Bosch Video Client or Bosch Video Management System 1 2 1 Password protection in camera A camera offers the option of limiting access across various authorization levels If the camera is password protected a message to enter the password appears 1 Enter the user name and the associated password in the appropriate fields 2 Click OK If the pas...

Страница 13: ...e items LIVEPAGE RECORDINGS SETTINGS Note The RECORDINGS link is only visible if a storage medium has been configured for recording With VRM recording this option is not active 2 1 Livepage The LIVEPAGE is used to display the live video stream and control the camera 2 2 Recordings The RECORDINGS page is used for playing back recorded sequences 2 3 Settings The SETTINGS page is used to configure th...

Страница 14: ...tially displayed It shows the live video image on the right of the browser window Depending on the configuration various text overlays may be visible on the live video image Other information may also be shown next to the live video image The items shown depend on the settings on the LIVEPAGE Functions page Figure 3 1 Livepage 3 1 1 Image selection Click a tab below the video image to display a ca...

Страница 15: ... reference this frame they might also show decoding errors but won t be marked with the icon Alarm flag Shown on a media item to indicate an alarm Communication error A communication error such as a connection failure to the storage medium a protocol violation or a timeout is indicated by this icon An automatic reconnection procedure is started in the background to recover from this error Gap Indi...

Страница 16: ...rol the pan and tilt of PTZ cameras Click and hold the up or down arrows to tilt Click and hold the left or right arrows to pan Click and hold the center area to control both Move the mouse cursor over the video image additional options for controlling peripherals are displayed with the mouse cursor Zoom focus and iris To control the zoom focus and iris of PTZ cameras 1 Click and hold to zoom out ...

Страница 17: ...The alarm symbol is for information and indicates the input status of the alarm input Active 1 Symbol lights Active 0 Symbol not lit The camera relay allows the operation of an external device for example a light or a door opener To operate click the relay symbol The symbol is red when the relay is activated 3 1 5 System Log Event Log The System Log field contains information about the operating s...

Страница 18: ... on the computer s hard drive The sequences are recorded at the resolution specified in the encoder configuration The storage location depends on the configuration of the camera 1 Click the recording icon to record video sequences Saving begins immediately The red dot on the icon indicates that a recording is in progress 2 Click the recording icon again to stop recording Play back saved video sequ...

Страница 19: ...ra 2 Release the key to stop sending audio All connected users receive audio signals sent from the camera but only the user who first pressed the F12 key can send audio signals others must wait for the first user to release the key 3 1 10 Processor load When accessing the camera with a browser the processor load and network information is available in the upper right of the window next to the Bosc...

Страница 20: ...d in a list A track number is assigned to each sequence Start time and stop time recording duration number of alarms and recording type are displayed To play back recorded video sequences 1 Select Recording 1 or 2 in the drop down menu The contents for 1 and 2 are identical only the quality and location may be different 2 Use the arrow buttons to browse the list 3 Click a track The playback for th...

Страница 21: ...quences Change the time interval displayed by clicking the plus or minus icons The display can span a range from two months to a few seconds If required drag the green arrow to the point in time at which the playback should begin Red bars indicate the points in time where alarms were triggered Drag the green arrow to navigate to these points quickly Control buttons Control playback by means of the...

Страница 22: ...sequence and jump to these directly These bookmarks are indicated as small yellow arrows above the time interval Use the bookmarks as follows Jump to the previous bookmark Set bookmark Jump to the following bookmark Bookmarks are only valid while in the Recordings page they are not saved with the sequences All bookmarks are deleted when you leave the page ...

Страница 23: ...iguring the unit or checking the current settings Basic Mode Advanced Mode In Basic Mode the most important parameters are arranged in seven groups This allows you to change the basic settings with just a few entries and then put the device into operation Advanced Mode is recommended only for expert users or system support personnel You can access all device parameters in this mode Settings that a...

Страница 24: ...e When entering names do not use any special characters for example Special characters are not supported by the internal recording management system Saving changes After making changes in a window click Set to send the new settings to the device and save them there Clicking Set saves only the settings in the current window Changes in any other windows are ignored Click SETTINGS in the applications...

Страница 25: ...uration menu allows a set of basic camera parameters to be configured 5 2 Advanced Mode menu tree The advanced mode configuration menu contains all camera parameters that can be configured Basic Mode Device Access Date Time Network Encoder Audio Recording System Overview Advanced Mode General Web Interface Encoder Camera Recording Alarm Interfaces Network Service ...

Страница 26: ...ctions of the camera and allows all configuration settings to be changed user is the middle authorization level This user can operate the device play back recordings and also control a camera but cannot change the configuration live is the lowest authorization level It can only be used to view the live video image and switch between the different live image displays You can define and change a pas...

Страница 27: ...assword for each level Enter the password 19 characters maximum for the selected level Confirm password Re enter the new password to ensure that there are no typing mistakes The new password is only saved after clicking Set Therefore click Set immediately after entering and confirming the password even if assigning a password at another level ...

Страница 28: ...he device Time server IP address The camera can receive the time signal from a time server using various time server protocols and then use it to set the internal clock The device polls the time signal automatically once every minute Enter the IP address of a time server Time server type Select the protocol that is supported by the selected time server It is recommended that you select the SNTP se...

Страница 29: ...ot DHCP If the network has a DHCP server for dynamic IP address allocation set this parameter to On to activate the automatic acceptance of DHCP assigned IP addresses For certain applications the DHCP server must support the fixed assignment between IP address and MAC address and must be appropriately set up so that once an IP address is assigned it is retained each time the system is rebooted IP ...

Страница 30: ...re displayed 6 5 Audio Switch the camera audio On or Off Use the slider to adjust the level 6 6 Recording Record the images from the camera to a storage medium For long term authoritative images it is essential to use VRM or an appropriately sized iSCSI system Storage medium 1 Select the required storage medium from the list 2 Click Start to start recording or Stop to end recording 6 7 System Over...

Страница 31: ...e to assist in identification This name simplifies the management of multiple devices in more extensive systems The name is used for remote identification for example in the event of an alarm Choose a name that makes it as easy as possible to identify the location unambiguously 7 1 3 iSCSI Initiator extension Add text to an initiator name to make identification easier in large iSCSI systems This t...

Страница 32: ...splays You can define and change a password for each authorization level if you are logged in as service or if the camera is not password protected Use the various authorization levels to limit access Proper password protection is only guaranteed if all higher authorization levels are also protected with a password For example if a live password is assigned a service and a user password should als...

Страница 33: ...sary to enter the day of the week it is added automatically 2 Enter the current time or click Sync to PC to apply the system time from your computer to the device Note It is important that the date time is correct for recording An incorrect date time setting could prevent correct recording 7 3 3 Device time zone Select the time zone in which the system is located 7 3 4 Daylight saving time The int...

Страница 34: ...er the table to change the selected entry Changes are immediate 8 If there are empty lines at the bottom of the table for example after deletions add new data by marking the row and selecting values from the list boxes 9 When finished click OK to save and activate the table 7 3 5 Time server IP address The camera can receive the time signal from a time server using various time server protocols an...

Страница 35: ...ing Select the position of the time and date overlay in the drop down box It can be displayed at the Top at the Bottom or at a position of choice using the Custom option or it can be set to Off for no overlay information If the Custom option is selected enter values in the X and Y position fields 7 4 3 Display milliseconds If necessary display milliseconds for Time stamping This information can be...

Страница 36: ...Enter the message to be displayed on the image in the event of an alarm The maximum text length is 31 characters 7 4 6 Video watermarking Select On in the drop down box for the transmitted video images to be watermarked After activation all images are marked with an icon The icon indicates if the sequence live or saved has been manipulated ...

Страница 37: ... for access to local files or http www myhostname com images logo gif for access via the Internet Intranet There must be a network connection to display the images The image files are not stored on the camera To restore the original graphics delete the entries in the Company logo and Device logo fields 8 1 1 Website language Select the language for the user interface 8 1 2 Company logo To replace ...

Страница 38: ...m inputs The alarm inputs are displayed next to the video image as icons along with their assigned names If an alarm is active the corresponding icon changes color 8 2 3 Show relay outputs The relay output is shown next to the video image as an icon along with its assigned name If a relay is switched the icon changes color 8 2 4 Show VCA trajectories The trajectories motion lines of objects from t...

Страница 39: ...cify whether the icon for saving individual images should be displayed below the live image Individual images can only be saved if this icon is visible 8 2 9 Allow local recording Specify whether the icon for saving video sequences locally should be displayed below the live image Video sequences can only be saved if this icon is visible 8 2 10 Path for JPEG and video files Enter the path for the s...

Страница 40: ...ny text editor or standard office software File for event log Enter the path for saving the event log here If necessary click Browse to find a suitable folder 8 3 2 Save system log Select this option to save system messages in a text file on the local computer This file can be viewed edited and printed with any text editor or standard office software File for system log Enter the path for saving t...

Страница 41: ...t On to output an upside down camera image 9 1 4 Menu button Select Disabled to prevent access to the install wizard via the menu button on the camera itself 9 1 5 Heater dome cameras only Select Auto to let the camera determine when the heater should be switched on 9 1 6 Restore all defaults Click Restore all defaults to restore the factory defaults for the camera A confirmation screen appears Al...

Страница 42: ...t the size and position of the shaded area in the preview window Check the Show only selected area box to make the main window zoom in on the selected area 2 Check the IR corrected lens box to have the same focus positions for day and night To adjust the night focus for a non IR corrected lens the camera must be in the night mode 3 Click Full range autofocus to focus the lens across its full range...

Страница 43: ...tion In Manual mode the Red Green and Blue gain can be manually set to a desired position Hold Click Hold to put ATW on hold and save the color settings R gain In Manual white balance mode adjust the red gain from 50 to 50 to offset the factory white point alignment reducing red introduces more cyan B gain In Manual white balance mode adjust the blue gain from 50 to 50 to offset the factory white ...

Страница 44: ...hutter speed The camera tries to maintain the selected default shutter speed as long as the light level of the scene permits Select the minimum frame rate for automatic exposure 1 6 to 1 25 ips or 1 9 to 1 30 ips The values available depend on the value set for the Base Frame Rate in the Installer Menu Fixed exposure Select to set a fixed shutter speed Select the shutter speed for fixed exposure 1...

Страница 45: ...ty Color the camera always produces a color signal regardless of light levels Switch level Set the video level at which the camera in Auto mode switches to monochrome operation 15 to 0 to 15 A low negative value means that the camera switches to monochrome at a lower light level A high positive value means that the camera switches to monochrome at a higher light level ...

Страница 46: ... A low negative value makes the picture less sharp Increasing sharpness brings out more detail Extra sharpness can enhance the details of license plates facial features and the edges of certain surfaces but can increase bandwidth requirements 9 5 2 Backlight Compensation Select On to capture details in high contrast and extremely bright dark conditions 9 5 3 Contrast enhancement Select On to incre...

Страница 47: ...ructures The camera simultaneously generates two H 264 video streams and an M JPEG stream for transmission An I frame only stream is used for recording Select the compression settings of these streams individually for example one setting for transmissions to the Internet and one for LAN connections Refer to Section 10 1 Encoder Profile page 50 for more information on setting up the encoder profile...

Страница 48: ...e to define the area for each of the masks 9 8 Audio Switch the audio On or Off Adust the Line In and Line Out levels with the sliders Select G 711 or ACC as the audio Recording format The default value is G 711 Note The audio signals are sent in a separate data stream parallel to the video data and so increase the network load The audio data requires an additional bandwidth of approximately 80 kb...

Страница 49: ...recording M JPEG streams The bit rates the encoding interval and the Group of Pictures GoP structure and quality are defined and stored for 8 different profiles on the Encoder Profile page The SD Standard Definition resolution is also selected here The resolution of the two H 264 streams and the pre defined profile to be used for each stream is selected on the Encoder Streams page The maximum fram...

Страница 50: ...quality High resolution with lower data rate HD low bandwidth High resolution for low bandwidth connections SD high quality low latency Standard resolution for high bandwidth connections SD high quality Standard resolution with lower data rate SD low bandwidth Standard resolution for low bandwidth connections DSL Standard resolution for DSL connections ISDN 2B Low resolution for mobile phone conne...

Страница 51: ...ny circumstances Depending on the video quality settings for the I frames and P frames this can result in individual images being skipped The value entered here must be at least 10 higher than the value entered in the Target bit rate field If the value entered here is too low it is automatically adjusted 10 1 6 Encoding interval The Encoding interval slider determines the interval at which images ...

Страница 52: ...entry of 3 means that every third image is an I frame The lower the number the more I frames are generated I frame quality This setting sets the image quality of the I frames Select Auto to ensure that the maximum bit rate is not exceeded Auto automatically changes the I frame quality to the settings for the P frame image quality P frame quality This setting adjusts the maximum image quality of th...

Страница 53: ...hen a stream is used for recording the profile selected on the Recording Profiles page is used Note The frame rate used for these streams is determined by the value selected for the Base Frequency in the Installer Menu Preview Previews of streams 1 and 2 can be shown 1 Click Preview to display a preview of the video for streams 1 and 2 the current profile is shown above the preview 2 Click 1 1 Liv...

Страница 54: ...et the parmeters for the M JPEG stream Select the Max frame rate in images per second IPS The Picture quality slider allows adjustment of the M JPEG image quality from Low to High Note The JPEG resolution follows the highest resolution setting of either stream 1 or stream 2 The M JPEG frame rate can vary depending on system loading ...

Страница 55: ...y sized iSCSI system Two recording tracks are available Recording 1 and Recording 2 The encoder streams and profiles can be selected for each of these tracks for both standard and alarm recordings Ten recording profiles are available where these recording tracks can be defined differently These profiles are then used for building schedules A Video Recording Manager VRM can control all recording wh...

Страница 56: ...torage medium a connection to the desired iSCSI system is required to set the configuration parameters The storage system selected must be available on the network and completely set up It must have an IP address and be divided into logical drives LUNs 1 Enter the IP address of the required iSCSI destination in the iSCSI IP address field 2 If the iSCSI destination is password protected enter the p...

Страница 57: ...he other available drives The medium is added as a target in the Managed storage media list Newly added media is shown as Not active in the Status column 2 Click Set to activate all media in the Managed storage media list The Status column shows all media as Online 3 Check the box in the Rec 1 or Rec 2 column to specify the recording tracks to be recorded on the target selected 4 Check the Recordi...

Страница 58: ...storage medium in the Managed storage media list to select it 2 Click Edit below the list 3 Click Format in the new window to delete all recordings in the storage medium 4 Click OK to close the window 11 1 5 Deactivating storage media A storage medium in the Managed storage media list can be deactivated It is then no longer used for recordings 1 Click a storage medium in the Managed storage media ...

Страница 59: ...Settings A window opens to select the target profiles for the copied settings If you change a profile s settings click Set to save If necessary click Default to return all settings to their factory defaults Stream profile settings Select the encoder profile setting that is to be used with stream 1 and 2 when recording This selection is independent of the selection for live stream transmission The ...

Страница 60: ...arameters for track 2 as described below 11 2 2 Standard recording Select the mode for standard recordings Continuous the recording proceeds continuously If the maximum recording capacity is reached older recordings are overwritten automatically Pre alarm recording takes place in the pre alarm time during the alarm and during the post alarm time only Off no automatic recording takes place Stream S...

Страница 61: ...to FTP box to send standard H 264 files to the FTP server whose address is displayed If an FTP server has not yet been defined click Configure FTP server to jump to the FTP Posting page where the server information can be entered Alarm triggers Select the alarm type that is to trigger an alarm recording Alarm input Motion Audio alarm Video loss alarm Select the Virtual alarm sensors that are to tr...

Страница 62: ...ntion Time If the available capacity of a medium has been fully used older recordings are only overwritten when the retention time entered here has expired Enter the required retention time in hours or days for each recording track Make sure that the retention time does not exceed the available recording capacity ...

Страница 63: ...elected profile 3 Use the right mouse button to deselect any of the intervals 4 Click Select All to select all of the intervals to be assigned to the selected profile 5 Click Clear All to deselect all of the intervals 6 When finished click Set to save the settings to the device 11 4 2 Holidays Define holidays whose settings will override the settings for the normal weekly schedule 1 Click the Holi...

Страница 64: ...vate recording After completing configuration activate the recording schedule and start scheduled recording Once activated the Recording Profiles and the Recording Scheduler are deactivated and the configuration cannot be modified Stop scheduled recording to modify the configuration 1 Click Start to activate the recording schedule 2 Click Stop to deactivate the recording schedule Recordings that a...

Страница 65: ...er Interface Recording en 65 Bosch Security Systems Software manual AM18 Q0605 v5 0 2011 07 11 5 Recording Status Details of the recording status are displayed here for information These settings cannot be changed ...

Страница 66: ... device maintains the connection for as long as an alarm exists 12 1 2 Number of destination IP address Specify the numbers of the IP addresses to be contacted in the event of an alarm The device contacts the remote locations one after the other in the numbered sequence until a connection is made 12 1 3 Destination IP address For each number enter the corresponding IP address for the desired remot...

Страница 67: ...smission If the device is operated behind a firewall select TCP HTTP port as the transfer protocol For use in a local network select UDP To enable multicast operation select the UDP option for the Video transmission parameter here and on the Network page Note In the event of an alarm a larger network bandwidth is sometimes required for additional video streams if multicast operation is not possibl...

Страница 68: ...assword By selecting On only encrypted ports are available for the Remote port parameter SSL encryption must be activated and configured on both sides of a connection The appropriate certificates must also have been uploaded Configure and activate encryption for media data video metadata on the Encryption page 12 1 10 Auto connect Select On to automatically re established a connection to one of th...

Страница 69: ... view Detection of movement can be used to trigger an alarm and to transmit metadata Various VCA configurations can be selected and adapted to your application as required Refer to Section 13 Setting up VCA page 74 for more information on setting up video content analyses Note If there is not enough computing power priority is given to live images and recordings This can lead to impairment of the ...

Страница 70: ...with the Bosch Video Client and the Bosch Video Management System Enter a unique and clear name here 12 3 3 Signal Ranges Exclude particular signal ranges in order to avoid false alarms For this reason the total signal is divided into 13 tonal ranges mel scale Check or uncheck the boxes below the graphic to include or exclude individual ranges 12 3 4 Threshold Set up the threshold on the basis of ...

Страница 71: ...are sent to the mail server via the address entered Otherwise leave the box blank 0 0 0 0 12 4 3 SMTP user name Enter a registered user name for the chosen mail server 12 4 4 SMTP password Enter the required password for the registered user name 12 4 5 Format Select the data format of the alarm message Standard with JPEG e mail with JPEG image file attachment SMS e mail in SMS format to an e mail ...

Страница 72: ...l address for alarm e mails here The maximum address length is 49 characters 12 4 8 Sender name Enter a unique name for the e mail sender for example the location of the device This makes it easier to identify the origin of the e mail 12 4 9 Test e mail Click Send Now to test the e mail function An alarm e mail is immediately created and sent ...

Страница 73: ... to the alarm settings on the various alarm pages enter the desired alarm functions in script form here This will overwrite all settings and entries on the other alarm pages 1 Click Examples under the Alarm Task Editor field to see some script examples A new window opens 2 Enter new scripts in the Alarm Task Editor field or change existing scripts in line with your requirements 3 When finished cli...

Страница 74: ...lable Off Silent MOTION Profile 1 Profile 2 Scheduled Event triggered 13 1 VCA Silent MOTION The Silent MOTION configuration is active by default In this configuration metadata is created to facilitate searches of recordings however no alarm is triggered In the VCA configuration drop down list select Silent MOTION No parameters can be changed for this selection ...

Страница 75: ...file A new window opens where you specify the file name and the location 4 Click Load to load a saved profile A new window opens where you select the location and the profile file To rename a profile 1 To rename the file click the icon to the right of the list field and enter the new profile name in the field 2 Click the icon again The new profile name is saved The current alarm status is displaye...

Страница 76: ...rity Systems 13 2 3 Motion detector Motion detection is available for the Motion analysis type For the detector to function the following conditions must be met Analysis must be activated At least one sensor field must be activated The individual parameters must be configured to suit the operating environment and the desired responses The sensitivity must be set to a value greater than zero Note R...

Страница 77: ... an alarm event must last at least 1 second to trigger an alarm Selecting the area Select the areas of the image to be monitored by the motion detector The video image is subdivided into square sensor fields Activate or deactivate each of these fields individually To exclude particular regions of the camera s field of view from monitoring due to continuous movement by a tree in the wind for exampl...

Страница 78: ...e interval in seconds has elapsed and then only if the triggering condition still exists If the original condition has been restored before this time interval elapses the alarm is not triggered This avoids false alarms triggered by short term changes for example cleaning activities in the direct field of vision of the camera Global change slider Set how large the global change in the video image m...

Страница 79: ...ve a reference image that can be continuously compared with the current video image If the current video image in the marked areas differs from the reference image an alarm is triggered This detects tampering that would otherwise not be detected for example if the camera is turned 1 Click Reference to save the currently visible video image as a reference 2 Click Select Area and select the areas in...

Страница 80: ...to square fields Activate or deactivate each of these fields individually Select only those areas for reference monitoring in which no movement takes place and that are always evenly lit as false alarms could otherwise be triggered 1 Click Select Area to configure the sensor fields A new window opens 2 If necessary click Clear All first to clear the current selection fields marked yellow 3 Left cl...

Страница 81: ... the table hold down the mouse button and drag the cursor over all the periods to be assigned to the selected profile 3 Use the right mouse button to deselect any of the intervals 4 Click Select All to link all time intervals to the selected profile 5 Click Clear All to deselect all of the intervals 6 When finished click Set to save the settings in the device 13 3 2 Holidays Define holidays on whi...

Страница 82: ...are manual Bosch Security Systems Deleting Holidays Delete defined holidays at any time 1 Click Delete A new window opens 2 Click the date to delete 3 Click OK The item is deleted from the table and the window closes 4 The process must be repeated for deleting additional days ...

Страница 83: ... alarm scripts for example 13 4 2 Trigger active Select the VCA configuration here that is to be enabled via an active trigger A green check mark to the right of the list field indicates that the trigger is active 13 4 3 Trigger inactive Select the VCA configuration here that is to be activated if the trigger is not active A green check mark to the right of the list field indicates that the trigge...

Страница 84: ...played below the icon for the alarm input on the LIVEPAGE if configured 14 2 Relay Configure the switching behavior of the relay output Select different events that automatically activate an output For example turn on a floodlight by triggering a motion alarm and then turn the light off again when the alarm has stopped 14 2 1 Idle state Select Open for the relay to operate as an N O contact or sel...

Страница 85: ...t a controllable unit from the list If you wish to use the serial port to transmit transparent data select Transparent Select Terminal if you wish to operate the unit from a terminal After selecting a unit the remaining parameters in the window are set automatically and should not be changed 14 3 2 Camera ID If necessary enter the ID of the peripheral you wish to control for example a dome camera ...

Страница 86: ...1 1 Automatic IP assignment If a DHCP server is employed in the network for the dynamic assignment of IP addresses activate acceptance of IP addresses automatically assigned to the device Certain applications VIDOS Bosch Video Management System Archive Player Configuration Manager use the IP address for the unique assignment of the device If using these applications the DHCP server must support th...

Страница 87: ...device is used behind a firewall TCP Port 80 should be selected as the transmission protocol For use in a local network choose UDP Multicast operation is only possible with the UDP protocol The TCP protocol does not support multicast connections The MTU value in UDP mode is 1514 bytes 15 1 7 HTTP browser port Select a different HTTP browser port from the list if required The default HTTP port is 8...

Страница 88: ... port To allow only encrypted connections set the Off option to deactivate telnet support making telnet connections impossible 15 1 11 Interface mode ETH If necessary select the Ethernet link type for interface ETH Depending on the device connected it may be necessary to select a special operation type 15 1 12 Network MSS Byte Set the maximum segment size for the IP packet s user data here This gi...

Страница 89: ...ame Enter the host name registered on DynDNS org for the device here 15 1 16 User name Enter the user name registered at DynDNS org here 15 1 17 Password Enter the password registered at DynDNS org here 15 1 18 Force registration now Force the registration by transferring the IP address to the DynDNS server Entries that change frequently are not provided in the Domain Name System It is a good idea...

Страница 90: ... device does not send the traps automatically and will only reply to SNMP requests If one or two SNMP host addresses are entered SNMP traps are sent automatically Select Off to deactivate the SNMP function 15 2 2 1 SNMP host address 2 SNMP host address To send SNMP traps automatically enter the IP addresses of one or two target devices here 15 2 3 SNMP traps To choose which traps are sent 1 Click ...

Страница 91: ...manual AM18 Q0605 v5 0 2011 07 2 Enter the Password that the Radius server expects from the camera 15 2 5 RTSP port If necessary select a different port for the exchange of the RTSP data from the list The standard RTSP port is 554 Select Off to deactivate the RTSP function ...

Страница 92: ...m 225 0 0 0 to 239 255 255 255 class D address must be configured for multicast operation in a multicast enabled network The multicast address can be the same for multiple streams however it is necessary to use a different port in each case The settings must be made individually for each stream Enter a dedicated multicast address and port for each stream Switch between the streams by clicking the ...

Страница 93: ...5 3 3 Port Enter the port address for the stream here 15 3 4 Streaming Click the checkbox to activate multicast streaming mode An activated stream is marked with a check Streaming is typically not required for standard multicast operation 15 3 5 Multicast packet TTL A value can be entered to specify how long the multicast data packets are active on the network If multicast is to be run via a route...

Страница 94: ... added to the file name and automatically incremented by 1 When it reaches 255 it starts again from 000 Date time suffix The date and time are automatically added to the file name When setting this parameter ensure that the date and time of the device are always set correctly For eample the file snap011005_114530 jpg was stored on October 1 2005 at 11 45 and 30 seconds Posting interval Enter the i...

Страница 95: ...ra Browser Interface Network en 95 Bosch Security Systems Software manual AM18 Q0605 v5 0 2011 07 15 5 Encryption If an encryption license is installed this submenu gives access to the encryption parameters ...

Страница 96: ...To update the firmware 1 First store the firmware file on your hard disk 2 Enter the full path for the firmware file in the field or click Browse to locate and select the file 3 Click Upload to begin transferring the file to the device The progress bar allows monitoring of the transfer Service Maintenance Licenses System Overview CAUTION Before starting a firmware update make sure to select the co...

Страница 97: ...Download a dialog box appears 2 Follow the instructions to save the current settings To load configuration data from the computer to the device 1 Enter the full path of the file to upload or click Browse to select the desired file 2 Make certain that the file to be loaded comes from the same device type as the device to be reconfigured 3 Click Upload to begin transmission to the device The progres...

Страница 98: ...oad an internal maintenance log from the device to send it to Customer Service for support purposes Click Download and select a storage location for the file 16 2 Licenses This window is for the activation of additional functions by entering activation codes An overview of installed licenses is shown 16 3 System Overview This window is for information only and cannot be modified Keep this informat...

Страница 99: ......

Страница 100: ...Bosch Security Systems www boschsecurity com Bosch Security Systems 2011 ...

Отзывы: