I [A]
70
0
(ASM 50)
15
70
P17
I [A]
70
0
(ASM 50)
P17
15
70
P18
Commissioning
5–12
1070 066 028-101 (01.05) GB
5.1.7
Current limit
The admissible maximum current can be lower than the value selected via
this parameter depending on the clock frequency and the heat sink
temperature.
The actual value is displayed via A11 ’Actual current limit’.
P17 (A-0-0017)
I
max
reduction in general
min.
Range
[A]
max.
DM 4K
0.9
0.1
9.5 A
DM 8K
0.9
0.1
9.5 A
DM/DS 15K
1.5
0.5
15.9 A
DM 30K/A
3.1
0.5
31.8 A
DM/DS 45K/A
4.7
0.5
47.7 A
DM 85B
9.5
0.5
95.4 A
DM140D
12.7
0.5
127 A
factory setting
P18 (A-0-0018)
I
max
reduction with
I
red
signal
Limitation with 24V signal at terminal strip X13.4 (
I
RED
).
min.
Range
[A]
max.
DM 4K
0.9
0.1
9.5 A
DM 8K
0.9
0.1
9.5 A
DM/DS 15K
1.5
0.5
15.9 A
DM 30K/A
3.1
0.5
31.8 A
DM/DS 45K/A
4.7
0.5
47.7 A
DM 85B
9.5
0.5
95.4 A
DM140D
12.7
0.5
127 A
x
P17
limits
factory setting
.
Setting P17 subsequently to a value lower than P18 will render P18 in-
effective (P18 display flashing).