en | Rack installation

DIVAR IP all-in-one 7000 3U

2021.10 | V02 | DOC

Installation manual

Bosch Security Systems B.V.

5

Rack installation

This section provides information on installing the chassis into a rack unit. There are a variety
of rack units on the market, which may mean the assembly procedure will differ slightly. Also
refer to the installation instructions that came with the rack unit you are using.

i

Notice!

This rail will fit a rack between 26" and 33.5" deep.

5.1

Identifying the sections of the rack rails

The chassis package includes two rail assemblies, one designed and labeled for each side of
the chassis. Each assembly consists of an inner rail that secures directly to the chassis, and an
outer rail that secures to the rack. The outer rail has two sections that can slide and adjust to
fit your rack depth.

1

2

1

Right side inner rail

2

Right side outer rail

5.2

Separating the sections of the rack rails

The chassis package includes two rail assemblies in the rack mounting kit. Each assembly
consists of two sections:

an inner fixed chassis rail that secures directly to the chassis

an outer fixed rack rail that secures directly to the rack itself.

To separate the inner and outer rails:

1.

Locate the rail assembly in the chassis packaging.

2.

Extend the rail assembly by pulling it outward.

Содержание DIP-73G0-00N

Страница 1: ...DIVAR IP all in one 7000 3U DIP 73G0 00N DIP 73G8 16HD DIP 73GC 16HD en Installation manual ...

Страница 2: ......

Страница 3: ...dentifying the sections of the rack rails 20 5 2 Separating the sections of the rack rails 20 5 3 Installing the inner rails on the chassis 21 5 4 Installing the outer rails to the rack 22 5 5 Installing the chassis in the rack 22 6 Installing a SATA hard drive 24 6 1 Removing a hard drive carrier from a hard drive bay 24 6 2 Installing a hard drive into a hard drive carrier 25 6 3 Installing a ha...

Страница 4: ...ling a hard drive carrier into a rear hard drive bay 35 10 6 Replacing the DVD ROM drive 35 10 7 Replacing the front port panel 36 10 8 Installing the motherboard 37 10 9 Installing the air shroud 37 10 10 Replacing a system fan 37 10 11 Replacing the power supply 38 10 12 Replacing the power distributor 39 10 13 Service and repair 40 11 Additional information 41 11 1 Additional documentation and ...

Страница 5: ...not wear loose clothing such as neckties and unbuttoned shirt sleeves which can come into contact with electrical circuits or be pulled into a cooling fan Remove any jewelry or metal objects from your body which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present After accessing the inside ...

Страница 6: ...arning Lithium battery Batteries that have been inserted wrongly can cause an explosion Always replace empty batteries with batteries of the same type or a similar type recommended by the manufacturer Handle used batteries carefully Do not damage the battery in any way A damaged battery may release hazardous materials into the environment Dispose of empty batteries according to the manufacturer s ...

Страница 7: ...ire or electrical shock do not expose this unit to rain or moisture Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electrical shock Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them playing particular attention to...

Страница 8: ...ts Disconnect the power cables before installing or removing any components from the computer including the backplane When disconnecting power you should first turn off the system and then unplug the power cords from all the power supply modules in the system Disconnect the power cable before installing or removing any cables from the backplane When working around exposed electrical circuits anoth...

Страница 9: ... bags until ready for use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or printed circuits boards come into contact with your clothing which may retain a charge even if you are wearing a wrist strap Handle a board by its edges only Do not touch its components peripheral chips memory modules or contacts When handling chips or modules avoid to...

Страница 10: ...he unit Information on sales delivery storage and working life period No restrictions or conditions apply for the sale or delivery of this product If stored under the specified conditions the storage period is not restricted If used for the specified purpose in compliance with the safety instructions and technical specifications the working life period of the product is in accordance with normal e...

Страница 11: ...ication channels 1 9 Use latest software Before operating the device for the first time make sure that you install the latest applicable release of your software version For consistent functionality compatibility performance and security regularly update the software throughout the operational life of the device Follow the instructions in the product documentation regarding software updates The fo...

Страница 12: ... Bosch Security Systems B V 2 About this manual This manual is written for professional system integrators and PC technicians It provides information for the installation and use of the chassis Installation and maintenance should be performed by experienced and qualified technicians only ...

Страница 13: ...Air shrouds are shields usually plastic which conduct the airflow directly to where it is needed to maximize fan efficiency Always use the air shroud included with your chassis Power supply The chassis has redundant power supplies Redundant power supplies are hot swappable and can be changed without turning off the system Each power supply is auto switching capable This enables the power to automa...

Страница 14: ...ED 3 Information LED 4 NIC1 and NIC2 LEDs 5 HDD drive activity LED 6 Power LED 7 Reset button 8 Power button 9 Hard drive carrier LEDs Rear view 1 5 9 2 6 3 7 4 8 10 11 1 2 power supply modules 2 2 redundant SSD drives for operating system RAID1 mirror 3 IPMI LAN 4 3 USB ports 3 1 Gen 2 Type A 5 USB port 3 1 Gen 2 Type C 6 2 LAN ports teamed Note Do not change the teaming mode ...

Страница 15: ...re performing maintenance tasks Reset The reset button is used to reboot the system Control panel LEDs The control panel LEDs provide status information about the system LED Description Power failure This LED indicates that a power supply module has failed Information This LED indicates the system status System status Description Continuously on and red An overheat condition has occurred This may ...

Страница 16: ...nd one status LED Note For non RAID configurations some LED indications are not supported for example hot spare LED color LED state Description Activity LED Blue Solid On Hard drive is installed Blue Blinking I O activity Status LED Red Solid On Failed hard drive with RSTe support Red Blinking at 1 Hz Rebuild hard drive with RSTe support Red Blinking with two blinks and one stop at 1 Hz Hot spare ...

Страница 17: ... Installation manual 2021 10 V02 DOC LED color LED state Description Blinking The system power supply temperature has reached 63 C The system will automatically turn off when the power supply temperature reaches 70 C and restart when the power supply temperature goes below 60 C ...

Страница 18: ...our safety Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them This unit should be mounted at the bottom of the rack if it is the only unit in the rack When mounting this unit in a partially filled rack load the rack from the bottom to the top with the heaviest component at the bottom of the rack In single rack i...

Страница 19: ...ow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any poss...

Страница 20: ...il assemblies one designed and labeled for each side of the chassis Each assembly consists of an inner rail that secures directly to the chassis and an outer rail that secures to the rack The outer rail has two sections that can slide and adjust to fit your rack depth 1 2 1 Right side inner rail 2 Right side outer rail 5 2 Separating the sections of the rack rails The chassis package includes two ...

Страница 21: ...the chassis if you decide not to use a server rack The inner rail extension is attached to the inner rail to mount the chassis in the rack Caution Do not pick up the chassis with the front handles They are designed to pull the system from a rack only 1 2 3 To install the inner rails 1 Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis with the rail extensi...

Страница 22: ... to lock the system into place when installed and pushed fully into the rack which is its normal position Secondly these tabs also lock the system in place when fully extended from the rack This prevents the system from coming completely out of the rack when you pull it out for servicing 5 5 Installing the chassis in the rack You can install the chassis in a standard rack or in a Telco type rack W...

Страница 23: ...onally use screws to secure the front of the chassis to the rack Installing the chassis in a Telco type rack i Notice Do not use a two post Telco type rack To install the chassis in a Telco type rack 1 Determine how far the chassis will extend out the front of the rack Put larger chassis so that the weight between front and back is balanced If a bezel is included on the chassis remove it 2 Attach ...

Страница 24: ...have to perform following steps 1 Removing a hard drive carrier from a hard drive bay page 24 2 Installing a hard drive into a hard drive carrier page 25 3 Installing a hard drive carrier into a front drive bay page 26 6 1 Removing a hard drive carrier from a hard drive bay To remove a hard drive carrier from a hard drive bay 1 Press the release button to the right of the hard drive carrier This e...

Страница 25: ...ws which secure the dummy drive to the hard drive carrier 2 Remove the dummy drive from the hard drive carrier and place the hard drive carrier on a flat surface 3 Slide a new hard drive into the hard drive carrier with the printed circuit board side facing down 4 Align the mounting holes in both the hard drive carrier and the hard drive 5 Secure the hard drive to the hard drive carrier with the s...

Страница 26: ...red from Bosch are not supported For more information about supported hard disk drives see the datasheet in the Bosch Online Product Catalog at www boschsecurity com 6 3 Installing a hard drive carrier into a front drive bay To install a hard drive carrier into a hard drive bay 1 Insert the hard drive carrier horizontally into the hard drive bay orienting the hard drive carrier so that the release...

Страница 27: ...OC 7 Turning on the system To turn on the system 1 Plug the power cord from the power supply unit into a high quality power strip that offers protection from electrical noise and power surges Bosch recommends to use an uninterruptible power supply UPS 2 Push the power button on the control panel to turn on the system ...

Страница 28: ...rd drives using the MegaRAID Storage Manager application page 29 8 1 Default settings All DIVAR IP systems are preconfigured with a default IP address and with default iSCSI settings IP Address automatically assigned by DHCP fallback IP address 192 168 0 200 Subnet mask automatically assigned by DHCP fallback subnet mask 255 255 255 0 Default user settings for administrator account User name BVRAd...

Страница 29: ...ge Manager application i Notice The setup process with the MegaRAID Storage Manager application is not necessary for units with pre installed hard drives These units are delivered with a default configuration To configure RAID5 1 Install all hard drives 2 Turn on the system 3 Set up the operating system and install DIVAR IP Software Center as described in the user manual 4 After the DIVAR IP Softw...

Страница 30: ...ill be lost This option deletes data on all HDD partitions and overwrites the operating system partition with the factory default image Initial Factory Setup overwriting existing data This option deletes and overwrites data on all HDD partitions Furthermore it overwrites the operating system partition with the factory default image Note This procedure might take very long System Recovery back to F...

Страница 31: ...ion An overheating condition has occurred The system status LED is continuously on Make sure that no cables obstruct the airflow in the system Make sure that all fans are present and operating normally Make sure that the chassis covers are installed Make sure that the heat sinks are installed properly Make sure that the ambient room temperature is not too high ...

Страница 32: ... servicing this chassis 10 1 Replacement components Although not frequently you may need replacement parts for your system To ensure the highest level of professional service and technical support you must register the systems according to the instructions available as part of the shipment as well as online from the Bosch product catalog 10 2 Removing power from the system Before performing some s...

Страница 33: ...ocked position slide the cover toward the rear of the chassis and lift the cover off the chassis i Notice Except for short periods of time do NOT operate the server without the cover in place The chassis cover must be in place to allow proper airflow and prevent overheating 10 4 Identifying a faulty SSD drive The system provides tools for hard drive monitoring that are pre installed on the system ...

Страница 34: ...ive carrier into a rear hard drive bay page 35 10 5 1 Removing a hard drive carrier from a rear hard drive bay To remove a hard drive carrier from a hard drive bay 1 Press the release button to the right of the hard drive carrier This extends the hard drive carrier handle 2 Use the handle to pull the hard drive carrier out of the chassis i Notice Except for short periods of time swapping hard driv...

Страница 35: ...about supported hard disk drives see the datasheet in the Bosch Online Product Catalog at www boschsecurity com 10 5 3 Installing a hard drive carrier into a rear hard drive bay To install a hard drive carrier into a hard drive bay 1 Insert the hard drive carrier horizontally into the hard drive bay orienting the hard drive carrier so that the release button is on the right 2 Push the hard drive c...

Страница 36: ...he new drive unit in the slot until the tab locks in place 6 Reconnect the data and power cables 7 Replace the chassis cover replace the unit in the rack if necessary then turn on the system 10 7 Replacing the front port panel To replace the front port panel 1 Turn off and unplug the unit 2 Remove the chassis cover 3 Disconnect the power and data cables from the front port panel to other chassis c...

Страница 37: ... ensure a proper fit with the serverboard To check the air flow 1 Make sure there are no objects to obstruct airflow in and out of the chassis In addition if you are using a front bezel make sure the bezel s filter is replaced periodically 2 Do not operate the system without drives or drive trays in the drive bays Use only recommended material 3 Make sure no wires or foreign objects obstruct air f...

Страница 38: ...pull it completely from the chassis 1 2 1 Release tab 2 Airflow direction indicator 5 Place the new fan into the vacant space in the housing while making sure the arrows on the top of the fan indicating the airflow direction point in the same direction as the arrows on the other fans 6 Reconnect the power cord turn on the system and make sure that the fan is working properly before replacing the c...

Страница 39: ...cord of the failed power supply 2 Push the release tab on the back of the power supply 1 1 Release tab 3 Pull the power supply out using the handle provided 4 Replace the failed power supply with the same model 5 Push the new power supply into the power bay until you hear a click 6 Plug the AC power cord back into the power supply and turn on the unit 10 12 Replacing the power distributor Redundan...

Страница 40: ...m of the housing 7 Reconnect all the power cables replace the power supply and insert the plug into the wall 10 13 Service and repair The storage system is backed by a 3 year warranty Issues will be handled according to Bosch Service and Support guidelines The storage equipment is shipped with an original manufacturer Service and Support agreement The Bosch Technical Support is the Single Point of...

Страница 41: ...upgrade packages in the Download Area of Bosch Security and Safety Systems under https downloadstore boschsecurity com 11 2 Support services and Bosch Academy Support Access our support services at www boschsecurity com xc en support Bosch Security and Safety Systems offers support in these areas Apps Tools Building Information Modeling Warranty Troubleshooting Repair Exchange Product Security Bos...

Страница 42: ...42 Additional information DIVAR IP all in one 7000 3U 2021 10 V02 DOC Installation manual Bosch Security Systems B V ...

Страница 43: ......

Страница 44: ...Bosch Security Systems B V Torenallee 49 5617 BA Eindhoven Netherlands www boschsecurity com Bosch Security Systems B V 2021 202110281649 ...

Отзывы: