Note
: You can automate deleting unused images by running CleanupUnusedImages.exe /q in
quiet mode.
14.29
ONVIF Camera discovery
In the 3.60 software version, the default time to live of the ONVIF camera discovery increases
from 1 to 3. This allows the discovery of the ONVIF camera when it is connected to other
switches than the switch the server is connected to.
Add an environment variable to the system to change the time to live or the hop count. Name
the variable and set the desired time to live:
1.
Create a new environment variable via:
File explorer \ "This PC" \ Properties \ Advanced system settings \
Environment Variables \ System variables \ New
with variable name:
DCNM_ONVIF_DISCOVERY_TTL
.
2.
Restart the DICENTIS Server.
Note:
If you want the server to only discover the camera connected to the same switch you
might want to decrease the time to live to 1.