Operation
25
Condens 7000 WP – 6721842519 (2022/03)
• The burner was not in use for at least 28 days.
• After conversion from summer to winter mode.
The next time there is a heat demand for heating, the device is held at low
thermal output for 15 minutes. The siphon filling program remains active
until the device has completed 15 minutes of operation with increased
min. capacity.
During the siphon filling program,
Siphon fill. prog.
appears on the
display.
The siphon filling program is interrupted when the chimney sweep mode
is called up.
9.4
Settings in the service menu
Many device functions can be set and checked in the service menu. It
includes:
•
Info
: viewing information
•
Settings
: general and device-specific settings
•
Function check
: settings for function checks and start of function
checks
•
Reset
: restoring the factory settings, resetting the maintenance
intervals
9.4.1
Operating the service menu
Opening the service menu
▶ Press the DHW key and the Heating key simultaneously until the
service menu appears.
Closing the service menu
▶ Press the DHW key or the Heating key.
-or-
▶ Press the
d
key.
Navigating through the menu
▶ To highlight a menu or a menu item, press the
key or the
key.
▶ Press the
OK
key.
The menu or the menu item is displayed.
▶ To return to the next higher menu level, press the
d
key.
Changing the setting values
▶ Select the menu item with the OK
key.
▶ To select the desired value, press the
or the
key.
▶ Press the
OK
key.
The new value is saved.
Exiting the menu item without saving values
▶ Press the
d
key.
The value is not saved.
Overview of the service menu
Info
– Current status
– Current fault
– Fault history
– Boiler
– Max. heat output
– Flow temp.
– Set flow temp.
– Low-loss hdr.tmp
– Act. burner mod.
– Burner output
– Ionisation current
– Pump mod.
– Outside temp.
– Burner starts
– Hours run
– System pressure
– Hot water
– Max. output
– DHW flow rate
– DHW act. temp.
– Hot water temp.
– Inlet temp.
– DHW set temp.
– Autom. filling
– System pressure
– No. of refills
– Last refill dur.
– Refilling active
– System
– Contr.device ver.
– Progr. unit ver.
– Code plug no.
– Code plug ver.
– Solar
– Collector temp.
– Cyl.temp.bottom
– Collector pump
– Solar fault
Settings
– Hydraulics
– Low-loss header
– DHW configuration
– HC1 configuration
– Pump config.
–
Heating
– Max. heat output
– Standby time
– Anticyc. temp. off
– Anticycle temp. on
– Hot water
– Max. DHW output
– DHW circ. pump
– Cycle circ. pump
– TD-Temperature
– Start TD
– Stop TD
– Pump
– Pump ctr. mode
– Min. output
– Pump overrun
– Min. Sys. Pres.
– Target Sys. Pres.
– Special function
– Ventilation func.
– Siphon fill. prog.
– 3-WV mid. pos.
– Autom. filling
– System Fill
– Min. Sys. Pres.