Operating instructions

Air-Water Split Heat Pump

Compress 3000 AW

6 720 814 470-00.2I

230V 1N~ / 400V 3N~

6 720 818 009(2015/07)

ARUN-TWIN.

data in mm.

500, 600, 750, 900

1194

1754

2154

ARUN-TWIN model:
Standard design

The 

ARUN-TWIN

 model is the choice for perfectly tasteful and functional partitioning 

of living space. It is convincing with its striking design and high fl exibility: variable wall 

installation possible with no limitations.

Your advantages: 

Elegance down to the 

last detail guarantees a sophisticated 

interior design.

RAL 3005 
wine red

VOGEL

&

NOOT

CLIMATE CONTROL

 

   

SYSTEMS

Содержание Compress 3000 AW

Страница 1: ...Operating instructions Air Water Split Heat Pump Compress 3000 AW 6 720 814 470 00 2I 230V 1N 400V 3N 6 720 818 009 2015 07 ARUN TWIN VOGEL NOOT CLIMATE CONTROL SYSTEMS ...

Страница 2: ...nt disposal 12 Technical terms 13 1 Key to symbols and safety instructions 1 1 Key to symbols Warnings The following keywords are defined and can be used in this document NOTICE indicates a situation that could result in damage to property or equipment CAUTION indicates a situation that could result in minor to medium injury WARNING indicates a situation that could result in severe injury or death...

Страница 3: ...reeofcombustibleorchemically aggressive substances Do not use or store combustible or explosive materials paper propellants thinners paints etc within the vicinity of the appliance Do not use or store corrosive substances solvents adhesives chlorinatedcleaningagents etc withinthevicinityoftheappliance 2 General Compress 3000 heat pumps belong to a series of heating systems that recover energy from...

Страница 4: ...eration in heating mode is as follows The fan draws air through the evaporator The energy in the air causes the refrigerant to boil The gas which forms is routed to the compressor The pressure of the refrigerant in the compressor increases and its temperature rises The heated gas is routed under pressure to the condenser In the condenser the water in the heat transfer medium circuit absorbs the en...

Страница 5: ...with electric booster heater and external DHW cylinder AWBS IftheoutdoorunitiscombinedwiththeindoorunitAWBandDHWisalso to be produced via the heat pump an external DHW cylinder must be connected The changeover between heating and DHW is then effected byanexternal3 wayvalve Theindoorunitisequippedwithamixer This controls the heat from the external auxiliary heater which can be started from the indo...

Страница 6: ... display is active Press to open the info menu 6 Back key Press to return to the higher menu level or discard a changed value If the need for a service or a fault is displayed Press to switch between standard display and fault display Hold to switch from a menu to the standard display 7 Control knob Turn to change a setting value e g temperature or select from among the menus or menu items If the ...

Страница 7: ...g circuit 1 2 3 or 4 and press the selector Turn the selector to mark Heating Setback Elevate or Cooling Press the control knob Turn the selector and press it to activate the required setting e g for setback mode If the temperature control is activated Turn and press the selector to set the temperature The limits of the settingvalues for the temperatures are determined by the settings for the othe...

Страница 8: ...g system To activate optimised operation without time program Press the menu key to open the main menu Press the selector to open the Heating Cooling menu Press the selector to open the Operating mode menu If two or more heating circuits are installed turn the selector to highlight Heating circuit 1 2 3 or 4 and press the selector Turn the selector to highlight Optimise and press the selector Pres...

Страница 9: ...mber 2016 Contact your installer 5 7 Checking the safety valves The pressure relief valve should only drip once the maximum permissiblepressureintheheatingsystemhasbeenexceeded Ifthe pressure relief valve still drips at pressures below 2 bar please consult the principal contractor of the system Make sure that the liquid emerging from the pressure relief valve is visibly discharged into the drain 5...

Страница 10: ...MS AWMS solar Pull out the front panel at the bottom and pull up and off Firmly push the button at the overheating protection Reinsert the front panel Resetting the overheating protection at the indoor unit AWES Consult the system installer Fig 6 Indoor unit AWES 1 Pressure gauge The pressure regulator and overheating protection are only installed in the indoor unit with integrated electric booste...

Страница 11: ...e 11 6 720 818 009 2015 07 Compress 3000 AW Fig 7 Indoor unit AWMS AWM solar 1 Resetting the overheating protection 2 Particle filter 3 Pressure gauge 1 6 720 810 353 10 1I 3 2 VOGEL NOOT CLIMATE CONTROL SYSTEMS ...

Страница 12: ...r the IP module Manuf no __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ Login name ___ ___ ___ ___ ___ ___ ___ ___ ___ Password __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ Mac ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ 7 Environment disposal Environmental protection is a fundamental corporate strategy of the Bosch Group The quality of our products their efficiency an...

Страница 13: ...uced in the auxiliaryheateriscontrolledviaamixer Itisthereforealsoreferredtoas an auxiliary heater with mixer or boiler The user interface controls the connection and shutdown of the auxiliary heater according to the existing heat energy demand Heat sources are electric oil fired or gas fired boilers Primary circuit The part of the heating system that transports the heat from the heat pump to the ...

Страница 14: ...ime A certain time at which the heating system starts to heat or hot water is produced for example A switching time is a component of a time program Temperature of an operating mode Atemperaturethatisassignedtoanoperatingmode Thetemperatureis adjustable See the explanations on operating mode Flow temperature Temperature at which the heated water flows in the central heating system from the heat so...

Страница 15: ... 15 6 720 818 009 2015 07 Compress 3000 AW Notes ...

Страница 16: ...OT 8661 St Barbara Austria www vogelundnoot com int CLIMATE CONTROL SYSTEMS KE KELIT NZ Ltd 0800 4 KEKELIT 0800 4 5353548 climatecontrol kekelit co nz www kekelit co nz ...