Before using your air conditioning unit, please read this manual carefully and keep it for future reference.

6 720 862 438 (2016/04)

CLIMATE 5000 VRF

RDCI Series – All DC Inverter Outdoor Units

RDCI8/25-3, RDCI10/28-3, RDCI12/33-3, RDCI14/40-3, RDCI16/45-3

User Manual

Содержание CLIMATE 5000 VRF RDCI10/28-3

Страница 1: ...itioning unit please read this manual carefully and keep it for future reference 6 720 862 438 2016 04 CLIMATE 5000 VRF RDCISeries AllDCInverterOutdoorUnits RDCI8 25 3 RDCI10 28 3 RDCI12 33 3 RDCI14 40 3 RDCI16 45 3 User Manual ...

Страница 2: ...e tent person When a system is installed in a small room please install refrigerant leak detection equipment Should refrigerant come in to contact with a naked flame the gas can be extremely harmful Should a refrigerant leak occur switch off the power to the air conditioning unit Turn off any combustible heating devices ventilate the room and contact a competent person Do not use air conditioning ...

Страница 3: ...eration the fan motor in the outdoor unit may stop running under high temperatures When a indoor unit is in standby the fan will stop running to avoid draft Defrost in the heating operation During heating operation frost can accumulate on the outdoor unit To increase efficiency the unit will start defrosting automatcally for approximately 2 10minutes depending on the amount of accumulated frost Th...

Страница 4: ...discharge The master unit with slave units for different purposes when abnormal accident happen the director will illustrate When mode switches Indoor unit Bad odour Operation LED flashes No priority of Standby on panel is displayed Thawing frost light flashes in 30s Basic Checks Unit is operating at random periods Incorrect settings in the programmer No operation Checkthereisn torhasbeenaninterru...

Страница 5: ... unit to clear the fault 19 C7 PL protection has been activated 3 times in 100 minutes Must restart electrical power supply to unit to clear the fault 20 xHd Auxiliary unit error X 1 2 3 e g 1Hd stands for auxiliary unit1 error X represents an auxiliary unit 21 P0 Inverter compressor maximum temp protection 22 P1 High pressure protection 23 P2 Low pressure protection Should P2 fault occur more tha...

Страница 6: ...average temp Actual value 15 14 T3 pipe temp Left pipe temp Actual value 16 15 T5 pipe temp Right pipe temp Actual value 17 16 T4 ambient temp Actual value 18 17 Discharge temp of inverter compressor A Actual value 19 18 Discharge temp of inverter compressor B Actual value 20 19 Modual temp Actual value 21 20 Dischargepressurecorrespondingtothesaturationtemperature Actual value 30 22 21 The minimu...

Страница 7: ...n speed 0 stop 1 15 speed increase sequentially 15 is the max fan speed EXV opening angle Pulse count Display value 8 State of the evaporator or condenser 0 close condenser 1 All evaporator 2 Left evaporator right condenser 3 Left evaporator close Night noise control mode 0 Night silent mode factory settings 1 silent mode 2 Super silent mode 3 No silent mode Static pressure mode 0 static pressure ...