background image

6720886922 (2018/04) GB

SPLIT-TYPE ROOM AIR CONDITIONER

Climate 5000

RAC 2,6-2 IBW / OU- OUE

RAC 3,5-2 IBW / OU- OUE

RAC 5,3-2 IBW / OU- OUE

RAC 7-2 IBW / OU- OUE

Owner’s Manual

IMPORTANT NOTE:

Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.

Содержание Climate 5000 RAC 3

Страница 1: ...ate 5000 RAC 2 6 2 IBW OU OUE RAC 3 5 2 IBW OU OUE RAC 5 3 2 IBW OU OUE RAC 7 2 IBW OU OUE Owner s Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference ...

Страница 2: ...the air conditioner in a wet room e g bathroom or laundry room This can cause electric shock and cause the product to deteriorate Do not expose your body directly to cool air for a prolonged period of time ELECTRICAL WARNINGS Only use the specified power cable If the power cable is damaged it must be replaced by qualified personnel Do not use an extension cable or connect other appliances to the s...

Страница 3: ...ace objects on top of the outdoor unit Do not allow the air conditioner to operate for long periods of time with doors or windows open or if the humidity is very high Explanation of symbols displayed on the indoor unit or outdoor unit WARNING This symbol shows that this appli ance used a flammable refrigerant If the refrigerant is leaked and exposed to an external ignition source there is a risk o...

Страница 4: ... mode the unit will display the room temperature When error occurs it displays error code for 3 seconds when TIMER ON is set FRESH SWING TURBO or SILENCE features are turned on for 3 seconds when TIMER OFF is set FRESH SWING TURBO or SILENCE features are turned off when anti cold air feature is turned on when defrosting when unit is self cleaning when freeze protection is turned on when Wireless C...

Страница 5: ... your unit the louver will automatically resume its former angle For a detailed explanation of your unit s advanced functionality such as TURBO mode and its self cleaning functions refer to the Remote Control Manual NOTE ON ILLUSTRATIONS Illustrations in this manual are for explanatory purposes The actual shape of your indoor unit may differ The actual shape shall prevail Setting vertical angle of...

Страница 6: ... be activated via remote control Press the SLEEP button when you are ready to go to sleep When in COOL mode the unit will increase the temperature by 1 C after 1 hour and will increase by an additional 1 C after another hour When in HEAT mode the unit will decrease the temperature by 1 C after 1 hour and will decrease by an additional 1 C after another hour It will hold the new temperature for 5 h...

Страница 7: ...INTENANCE ALWAYS TURN OFF YOUR AIR CONDITIONER SYSTEM AND ISOLATE THE POWER SUPPLY BEFORE CLEANING OR MAINTENANCE CAUTION Only use a soft dry cloth to wipe the unit clean If the unit is especially dirty you can use a cloth soaked in warm water to wipe it clean Do not use chemicals or chemically treated cloths to clean the unit Do not use abrasive solvents or cleaning fluids to clean the unit They ...

Страница 8: ...rwillflashagainwhenyourestarttheunit Air Filter Replacement Reminder After2 880hoursofuse thedisplaywindowontheindoorunitwillflash nF This is a reminder to replace your filter After 15 seconds the unit will revert to its previous display To reset the reminder press the LED button on your remote control 4 times or press the MANUAL CONTROL button 3 times If you don t reset the reminder the nF indica...

Страница 9: ...e louver resets its position A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit s plastic parts Both the indoor unit and outdoor unit make noises Low hissing sound during operation This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units Low hissing sound when the system starts has just stopped running o...

Страница 10: ...place the fuse Remote control batteries are dead Replace batteries The unit s 3 minute protection has been activated Wait three minutes after restarting the unit Timer is activated Turn timer off The unit starts and stops fre quently There s too much or too little refrigerant in the system Check for leaks and recharge the system with refriger ant Incompressible gas or moisture has entered the syst...

Страница 11: ...his product as household waste or unsorted municipal waste When disposing of this appliance you have the following options Dispose of the appliance at designated municipal electronic waste collection facility Sell the appliance to certified scrap metal dealers Special notice Disposing of this appliance in the forest or other natural surroundings endangers your health and is bad for the environment...

Страница 12: ...Bosch Thermotechnology Ltd Cotswold Way Warndon Worcester WR4 9SW mailto Commercial enquiry uk bosch com Contact Number 03301233004 Web address www bosch industrial co uk ...