INVERTER ONE-TWIN/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Climate 5000 MS

18/27/36/42 OU- OUE

Owner’s Manual

IMPORTANT NOTE:

 

Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.

 

This manual only describes outdoor units. When using an indoor unit, refer to the user’s manual of the indoor unit.

Содержание Climate 5000 MS 18 OU

Страница 1: ...00 MS 18 27 36 42 OU OUE Owner s Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference This manual only describes outdoor units When using an indoor unit refer to the user s manual of the indoor unit ...

Страница 2: ...e voided if the unit is not installed by Qualified Personnel If an abnormal situation arises like smell of burning isolate the power supply and call qualified personnel for instructions to avoid electric shock fire or injury DO NOT let the indoor unit or the remote control get wet This may cause electric shock or fire DO NOT insert fingers rods or other objects into the air inlet or outlet This ma...

Страница 3: ...sage check the indoor unit to see if anything is damaged If the indoor unit is damaged it may fall and cause injury If the air conditioner is used together with other heating devices thoroughly ventilate the room to avoid oxygen deficiency DO NOT climb onto or place objects on top of the outdoor unit DO NOT operate the air conditioner when using fumigant insec ticides The chemicals may become laye...

Страница 4: ... controller Outdoor unit 6 Drain hose refrigerant connecting pipe 7 Connective cable 8 Stop valve 9 Fan hood Floor and standing type console One five One four One three One twin Fig 3 Indoor unit 1 Air flow louvre at air outlet 2 Air inlet containing air filter 3 Remote controller 4 Installation part 5 Display panel Outdoor unit 6 Drain hose refrigerant connecting pipe 7 Connective cable 8 Stop va...

Страница 5: ...7 C 32 C 0 C 30 C 10 C 32 C Outdoor Temperature 0 C 50 C 15 C 30 C 0 C 50 C 15 50 C For models with low temp cooling systems 0 C 60 C For special tropical models 0 C 60 C For special tropical models Table 1 Features Protection of the air conditioner Compressor protection The compressor cannot restart for 3 minutes after it stops Anti cold air Cooling and heating models only The unit is designed no...

Страница 6: ...will stop automatically and the air conditioner turns to FAN onlymode Thecompressorwillstartagainwhentheindoortemperature rises in COOL mode or falls in HEAT mode to the set point Droplets of water may form on the surface of the indoor unit when cooling occurs in relatively high humidity defined as higher than 80 Adjust the horizontal louvre to the maximum air outlet position and select HIGH fan s...

Страница 7: ...ents of the outdoor unit periodically Contact a local dealer or a customer service centre if the unit requires servicing NOTE Before you clean the air conditioner be sure to switch off the unit and isolate the power supply Optimal Operation To achieve optimal performance please note the following Adjust the direction of the air flow so that it is not blowing directly on people Adjust the temperatu...

Страница 8: ...EAT mode after defrosting white mist may be emitted due to moisture generated from the defrosting process The indoor unit makes noises A squeaking sound is heard when the system is OFF or in COOL mode The noise is also heard when the drain pump optional is in operation A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit s plastic parts Probl...

Страница 9: ...th refrigerant System circuit is blocked Determine which circuit is blocked and replace the mal functioning piece of equipment The compressor is broken Replace the compres sor The voltage is too high or too low Install a manostat to regulate the voltage Poor heating performance The outdoor tempera ture is lower than 7 C Check for leaks and recharge the system with refrigerant Cold air is entering ...

Страница 10: ......

Страница 11: ......

Страница 12: ...Bosch Thermotechnology Ltd Cotswold Way Warndon Worcester WR4 9SW mailto Commercial enquiry uk bosch com Contact Number 03301233004 Web address www bosch industrial co uk ...

Отзывы: