background image

 

 

 

 

EN 

Quick Reference Guide 

Solution Ultima 880 

 

CC488 

Содержание CC488

Страница 1: ...EN Quick Reference Guide Solution Ultima 880 CC488 ...

Страница 2: ...pyright Act 1968 Cth no part of this publication may be reproduced transmitted modified or stored in any form or by any means without the prior written permission of Bosch Notice of Liability This material is designed for use by tradespeople with expertise in the installation of this product Persons without appropriate expertise should seek assistance before attempting installation While care has ...

Страница 3: ...er 1 11 2 1 6 Phone Number 1 Receiver 2 11 2 1 7 Phone Number 2 Receiver 2 11 2 1 8 Handshake Tone For Receiver 2 11 2 1 9 Transmission Format For Receiver 2 11 2 1 10 Subscriber ID Number For Receiver 2 11 2 1 11 Dialling Format 11 2 1 12 Reserved 11 2 1 13 Telco Arming Sequence Call Forward On 11 2 1 14 Telco Disarm Sequence Call Forward Off 11 2 1 15 Call Back Telephone Number 11 2 1 16 Ring Co...

Страница 4: ...14 8 Siren Run Time 18 2 14 9 Siren Sound Rate 18 2 14 10 Auto Arming Pre Alert Time 18 2 14 11 Auto Arming Time 18 2 14 12 Auto Disarming Time 18 2 14 13 Kiss Off Wait Time 18 2 14 14 Speaker Beep Volume 19 2 15 Options Programming 19 2 15 1 System Options 1 19 2 15 2 System Options 2 19 2 15 3 System Options 3 19 2 15 4 System Options 4 19 2 15 5 Consumer Options 1 19 2 15 6 Consumer Options 2 1...

Страница 5: ...agram for Keyswitch Zone 24 Figure 8 Solution Ultima Series Wiring Diagram 25 Figure 9 Solution Ultima Series Component Overlay 26 Figure 10 Connections for CP 5 Master Partitioned CP500P Codepad and CP 5 Area Addressable CP500A Codepad 27 Figure 11 Connections for Two CP 5 Eight Zone Area Addressable CP500A Codepads 27 Tables Table 1 Quick Guide to Programming 6 Table 2 Codepad Indicators 7 Table...

Страница 6: ... to indicate that you entered programming mode The codepad indicators displays the current data programmed in LOCATION 000 first location of the Primary Telephone Number To move to another programming location enter the location number followed by the key The data in the new location is displayed using the codepad indicators For example if you enter 3 4 the system jumps to LOCATION 034 the beginni...

Страница 7: ...Table 3 Programming Option Bits Option Description 1 Dialler reporting functions allowed 2 Remote arming using telephone allowed 4 Answering machine bypass only when armed 8 Use bell 103 for FSK format Disabled CCITT V21 1 5 Installer s Programming Commands Installer Programming Commands displayed in Table 4 can only be used when you enter Installer s Programming Mode Enter the command followed by...

Страница 8: ... Enter the four character Installer Code or Master Code followed by 8 and the key for example 1 2 3 4 8 The last 40 events non partitioned or last ten events partitioned are displayed in reverse order for example most recent to least recent 1 11 Walk Test Mode 1 Enter the four character Installer Code or Master Code followed by 7 and the key for example 1 2 3 4 7 2 Test each zone as required 3 Pre...

Страница 9: ...d the key for example 2 5 8 0 1 2 Enter the User Number 1 to 16 you want to delete followed by the key 3 Press the key to delete the User Code 1 15 Change Domestic Telephone Numbers 1 Enter the four character Installer Code or Master Code followed by 2 and the key for example 1 2 3 4 2 2 Enter the digits for the telephone number 3 If there is more than one telephone number press the key followed b...

Страница 10: ... Latching Outputs Reset Press and hold the 7 key until two beeps are heard 1 23 Codepad ID Buzzer Tone 1 Press and hold the 8 key until the desired buzzer tone is reached If the system is partitioned CC488 only the codepad displays a number identifying which area the codepad belongs see Table 8 2 Press the key to exit Table 8 Codepad ID Buzzer Tone Zone LED Codepad Assignment 1 Area 1 2 Area 2 7 M...

Страница 11: ... Receiver 2 Location 056 to 071 Default 0 0 10 and telephone termination 0 Anywhere else 0 0 2 1 8 Handshake Tone For Receiver 2 Location 072 1 HI LO handshake contact ID 2 1400 Hz Ademco TX 1900 Hz 3 2300 Hz Sescoa TX 1800 Hz 4 No handshake 5 Pager 2 1 9 Transmission Format For Receiver 2 Location 073 1 Contact ID 2 4 2 Expressed 3 FSK 300 Baud 4 Domestic 5 Basic Pager 6 Reserved 7 Reserved 8 4 2...

Страница 12: ...umber required for upload download 4 Exit upload download connection on alarm 8 External modem module CC811 required for alarm link 2 2 Installer Code Location 181 to 184 Location Default 181 1 182 2 183 3 184 4 2 3 User Code Programming 2 3 1 User Codes Location 185 to 264 Location Default User 01 185 2 186 5 187 8 188 0 189 Authority Level 10 User 02 190 to 193 15 194 2 User 03 195 to 198 15 199...

Страница 13: ...se Count 282 0 Zone Pulse Count Time 283 0 Zone Options 1 284 1 Zone Options 2 285 14 Report Code 286 1 Dialler Options 287 1 2 6 1 Zone Defaults continued Location 267 to 322 Zone 04 Default Handover Zone Type 288 1 Zone Pulse Count 289 0 Zone Pulse Count Time 290 0 Zone Options 1 291 1 Zone Options 2 292 14 Report Code 293 1 Dialler Options 294 1 Zone 05 Default Instant Zone Type 295 0 Zone Puls...

Страница 14: ...one Options The keyswitch zone options replace Zone Options 1 only for the zones that were programmed to operate as a keyswitch zone Option Description 0 Latching arm and disarm in AWAY Mode 1 Latching arm in AWAY Mode 2 Latching disarm from AWAY Mode or STAY Mode 4 Latching arm and disarm in STAY Mode 5 Latching arm in STAY Mode 6 Latching disarm from STAY Mode 8 Momentary arm and disarm in AWAY ...

Страница 15: ...to Receiver 2 4 Report to both Receiver 1 and Receiver 2 8 Report to Receiver 2 only if Receiver 1 fails 2 10 Report Programming 2 10 1 Open Close Reports Location 345 to 346 Location Default Open Report 345 11 Close Report 346 12 2 10 2 Open Close Reporting Options Location 347 0 No Open Close Reports allowed 1 Report to Receiver 1 2 Report to Receiver 2 4 Report to both Receiver 1 and Receiver 2...

Страница 16: ... of day units digit 375 0 Test report tens digit 376 7 Test report units digit 377 1 Repeat interval in days 378 0 2 12 2 Test Reporting Dialler Options Location 379 0 No Codepad Alarm Reports allowed 1 Report to Receiver 1 2 Report to Receiver 2 4 Report to both Receiver 1 and Receiver 2 8 Report to Receiver 2 only if Receiver 1 fails 2 13 Output Programming 2 13 1 Outputs Location 380 to 409 Loc...

Страница 17: ...rol 3 2 11 Radio control output 1 2 12 Radio control output 2 2 13 Radio control output 1 not in AWAY Mode 2 14 Radio control output 2 not in AWAY Mode 2 15 Communications fail after 3 attempts 2 13 2 Event Codes continued Event Code Description 3 0 Communications fail 3 1 Dialler disabled 3 2 Dialler active on line 3 3 Ring detect 3 4 Codepad panic multi break V1 05 3 5 Mimic zone 1 3 6 Mimic zon...

Страница 18: ...2 14 2 Entry Time 2 Location 412 to 413 Location Default Increments of 1 sec 0 to 15 sec 412 8 Increments of 16 sec 0 to 240 sec 413 2 2 14 3 Exit Time AWAY STAY Modes Location 414 to 415 Location Default Increments of 1 sec 0 to 15 sec 414 12 Increments of 16 sec 0 to 240 sec 415 3 2 14 4 Entry Guard Time For STAY Mode Location 416 to 417 Location Default Increments of 1 sec 0 to 15 sec 416 0 Inc...

Страница 19: ... and 2 8 Alarm memory reset on disarm 2 15 7 Consumer Options 3 Location 442 1 Codepad fault beeps allowed 2 Use digit 3 for codepad duress alarm instead of digit 9 4 Alarms activate sirens and strobe outputs in STAY Modes 1 and 2 8 Zone tamper alarms to be silent 2 15 8 Radio Input Options Location 443 Default 0 1 RF Receiver RF 3212 E connected 2 Latching keyswitch input 3 Momentary keyswitch in...

Страница 20: ... Location Default Map RF Device 9 to Zone 1 to 8 536 0 Map RF Device 10 to Zone 1 to 8 537 0 Map RF Device 11 to Zone 1 to 8 538 0 Map RF Device 12 to Zone 1 to 8 539 0 Map RF Device 13 to Zone 1 to 8 540 0 Map RF Device 14 to Zone 1 to 8 541 0 Map RF Device 15 to Zone 1 to 8 542 0 Map RF Device 16 to Zone 1 to 8 543 0 2 20 4 Ring Burst Time V1 07 Location 748 to 749 Location Default Increments of...

Страница 21: ...stems 6 04 4998152446B 2 21 3 System Date Location 905 to 910 Location Default Day of the month tens digit 905 0 Day of the month units digit 906 1 Month of the year tens digit 907 0 Month of the year units digit 908 1 Current year tens digit 909 0 Current year units digit 910 1 ...

Страница 22: ...panel 2 Connect the RF Receiver to the control panel as shown above using 0 8 mm 22 AWG or larger wire Wire length should not exceed 300 m 1000 feet 3 Apply power to the control panel The red LED at the centre of the module turns on Operation The following describes the status of the module based on the LED condition LED On Module is functioning normally LED Off Power failure has occurred or modul...

Страница 23: ... 2 1 4 5 1 Button 4 Arm in STAY Mode 1 2 Button 3 Optional 3 Button 1 Arm in AWAY Mode 4 Button 2 Disarm from AWAY STAY Mode 5 Buttons 1 and 2 Press both buttons simultaneously to activate Panic alarm 5 0 Connections for Split EOL Resistors 5 1 8 Burglary Zones Figure 4 Split EOL Wiring Diagram Location 266 15 1 9 2 9 4 9 3 9 5 10 8 10 6 10 7 10 1 Zone 1 2 Zone 2 3 Zone 3 4 Zone 4 5 Zone 5 6 Zone ...

Страница 24: ...on Using N O Contacts Figure 6 Split EOL Wiring Diagrams Using N O Contacts 2 2 1 3 3 1 4 5 4 6 4 7 4 8 9 9 4 5 4 6 8 9 10 1 12 V 2 Zone Input 3 Zone 4 EOL 5 3k3 6 6k8 7 1k5 8 4k7 9 N O 10 N C 6 0 Wiring Diagrams 6 1 Keyswitch Zone Figure 7 Wiring Diagram for Keyswitch Zone 1 2 1 EOL 2 Keyswitch Momentary Toggle ...

Страница 25: ...9 6 8 14 15 10 11 12 13 10 10 11 1 605 Plug 2 1 Green Internal phone line 5 Yellow Internal phone line 2 Black Telecom line street 6 Red Telecom line street 3 and 4 Not used 3 Power to external equipment 12V 400 Ma 4 PIR 5 Piezo siren 6 Smoke detector 7 Link between 12 V and Comm 8 Strobe 9 Horn speaker 10 Yellow 11 Green 12 Red 13 Black 14 Codepad 15 18 VAC 1 3 A Plug Pack TF008 ...

Страница 26: ...ne IN Telecom line street IN Telecom line street 2 Termination for phone line 3 Socket for telecom lead connection 4 Receiver interface connection 5 Zone termination strip 6 Phone amplifier or direct link cable 7 Relay contact select 8 Programming key or hand help programmer plugs 9 Output termination strip 10 Default switch 11 3 A battery fuse 12 1 A accessory fuse 13 1 A codepad fuse 14 Battery ...

Страница 27: ...remote codepad must be in the ON position The following locations for Output 1 must be programmed LOCATION 380 6 381 1 Note The Master Partitioned Keypad requires setting all DIP switches to the ON position to operate correctly Figure 11 Connections for Two CP 5 Eight Zone Area Addressable CP500A Codepads 1 1 2 3 4 5 6 1 Data 2 CLK 3 12 V 4 GND 5 Area 1 Codepad 6 Area 2 Codepad The following DIP S...

Страница 28: ... 2004 Bosch Security Systems 4998152446B 05 SUB MA88Q 3323 Issue 1 73 Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 ...

Отзывы: