MY20B01 - 52_1.0_02.10.2019
46
Operation
6.3
Error message
6.3.1
Display
The drive system monitors itself continuously and
displays a number as an error message if a known
error is detected. The system may switch off
automatically depending on the type of error.
Code Description
Method of resolution
410
One or more display
buttons are blocked
Check whether buttons are
jammed because dirt has
accumulated between them,
for example. Clean the
buttons if they need cleaning.
414
Control panel connection
problem
Have ports and connections
checked. Contact your
specialist dealer.
418
One or more buttons on
the control panel are
blocked
Check whether buttons are
jammed because dirt has
accumulated between them,
for example. Clean the
buttons if they need cleaning.
419
Configuration error
1
Re-start the system.
2
Contact your specialist
dealer if the problem
persists.
422
Connection problem with
the drive unit
Have ports and connections
checked.
423
Connection problem with
the drive unit
Have ports and connections
checked.
424
Communication error with
components
communicating with one
another
Have ports and connections
checked.
426
Internal time-out error
It is not possible to display or
adjust the tyre size in the basic
settings menu in this error status.
1
Re-start the system.
2
Contact your specialist
dealer if the problem
persists.
430
Display battery flat
Recharge display battery
(while in its mount or using
USB port).
431
Software version error
1
Re-start the system.
2
Contact your specialist
dealer if the problem
persists.
440
Internal drive unit error
1
Re-start the system.
2
Contact your specialist
dealer if the problem
persists.
450
Internal software error
1
Re-start the system.
2
Contact your specialist
dealer if the problem
persists.
Table 49: List of display screen error messages
460
Error in USB port
1
Re-start the system.
2
Contact your specialist
dealer if the problem
persists.
490
Internal display error
Have display checked.
500
Internal drive unit error
1
Re-start the system.
2
Contact your specialist
dealer if the problem
persists.
502
Fault in the lighting
1
Check the light and its
cabling.
2
Re-start the system.
3
Contact your specialist
dealer if the problem
persists.
504
System responses to
detected tuning.
Pedelec switches to
emergency ride mode and
logs the error
Can be reset for 90 minutes
by riding in emergency mode
(possible 3 times).
If the error reoccurs, the
specialist dealer will need to
set up the system again.
503
Speed sensor error
1
Re-start the system.
2
Contact your specialist
dealer if the problem
persists.
510
Internal sensor error
1
Re-start the system.
2
Contact your specialist
dealer if the problem
persists.
511
Internal drive unit error
1
Re-start the system.
2
Contact your specialist
dealer if the problem
persists.
530
Battery error
1
Switch off system.
2
Remove the battery.
3
Re-insert battery.
4
Re-start electric drive
system.
5
Contact your specialist
dealer if the problem
persists.
531
Configuration error
1
Re-start the system.
2
Contact your specialist
dealer if the problem
persists.
540
Temperature error
The pedelec is outside the
permitted temperature
range
1
Switch off the system to cool
the drive unit down or warm
to the permitted temperature
range.
2
Re-start the system.
3
Contact your specialist
dealer if the problem
persists.
Code Description
Method of resolution
Table 49: List of display screen error messages
Содержание BULLS Twenty 6 EVO
Страница 103: ...MY20B01 52_1 0_02 10 2019 103 Documents 11 4 Charger operating instructions H I H I H ...
Страница 105: ...MY20B01 52_1 0_02 10 2019 105 Documents Compact Charger ...
Страница 106: ...MY20B01 52_1 0_02 10 2019 106 Documents ...
Страница 107: ...MY20B01 52_1 0_02 10 2019 107 Documents ...
Страница 108: ...MY20B01 52_1 0_02 10 2019 108 Documents ...