RE 95240-01-B/2021-01-12, Bosch Rexroth AG
Installation |
BODAS controller RC/3x and RC/4x
15
/24
7 Installation
Prior to installation, the following documents should be to hand:
• Product-specific data sheet (contains the permissible technical data,
main dimensions and circuit diagrams of standard versions), see Table 1
"Required and supplementary documentation" on page 4.
7.1 Unpacking
NOTICE!
Danger due to electrostatic discharge!
When unpacking the control unit, there is a danger of damage to the electronic
components of the control unit due to electrostatic discharge.
▶ During unpacking, the control unit is to be protected against electrostatic
discharge.
▶ Remove the packaging from the control unit.
▶ Check the control unit for transport damage and completeness, see chapter 4
"Scope of delivery" on page 11.
▶ Dispose of the packaging in accordance with the regulations in your country.
7.2 Installation conditions
▶ Do not install the control unit near parts which generate considerable heat
(e.g. exhaust).
▶ Radio equipment and mobile telephones must not be used in the driver's cab
without a suitable antenna or near the control electronics.
▶ A sufficiently large distance to radio transmission systems must be maintained.
▶ All connectors must be unplugged from the electronics during electrical welding
or painting operations.
▶ Cables/wires must be sealed individually to prevent water from entering the
control unit.
▶ The control unit must not be electrostatically charged, e.g. during painting.
▶ The control unit will heat up beyond normal ambient temperature during
operation. Protect the control unit from being touched in order to avoid hazards
caused by high temperatures.
▶ Install the control unit in such a way that the electrical plug is not facing upwards.
This ensures that any condensation water is drained.
▶ Standing and permanently running water are not permitted anywhere near the
circumferential groove (lid/base connector) or the pressure equalizing element
(DAE).
▶ The control unit must be fastened with metal screws in order to establish a good
thermal connection between the housing and the cooling surface (heat sink).