23
4.9
Adjustment functions
4.10 Reset
4.11
Error inquiry
i
Make sure that the Service switch is
set to
On
before you open the Setting
functions menu.
For details on how to adjust the exhaust-
gas analyzer module and undertake
country-specific settings, please refer to
Section 4.5.1 (country-specific settings).
Return to the function menu by clicking
Back
or by pressing keys
Alt + B.
A reset must be performed when entries
have been modified in the
Setting
functions
menu. These modified
settings will only be stored in the
flashprom of the exhaust-gas analyzer
module after a reset.
Select
Yes
by clicking it or with the tab
key
. Confirm that you wish to perform
a reset with
E
or by double-clicking the
mouse.
The fault memory is deleted and the
exhaust-gas analyzer module is restarted.
i
For approx. 15 s, the exhaust-gas
analyzer module has no connection to
the laptop or PC.
The following message therefore appears:
The measuring device reported hardware
failure!
The error code must be read!
After 15 s, restart the Service program
with
E
or by clicking
OK
.
Any current faults in the exhaust-gas
analyzer module are displayed in plain
text.
Confirm the readout of the fault memory
with
E
or by clicking
OK
. The fault
memory is deleted and the screen returns
to the Function menu.
i
If a fault still remains in the exhaust-
gas analyzer, this will be displayed
again.
Содержание BEA 150
Страница 91: ...92 12 Overview 12 1 Electrical wiring Siemens analysis chamber 459716 2Ha ...
Страница 94: ...95 12 4 Hosing Siemens analysis chamber X26 X24 X25 X22 X5 LP 223 X19 459716Ht ...
Страница 96: ...97 12 6 Electrical wiring Andros analysis chamber 4597162Ht ...
Страница 99: ...100 12 9 Hosing Andros analysis chamber 459869_03Ht ...
Страница 100: ...101 12 10 Gas circuit diagram Andros analysis chamber ...