1 689 989 131
2019-03-02
|
Robert Bosch GmbH
| BAT 131 | 27
en
6. Maintenance &
Troubleshooting
6.1
Cleaning
The housing and the display of the BAT 131 may only be
cleaned using soft cloths and neutral cleaning agents.
Do not use any abrasive cleaners or coarse workshop
cleaning rags.
6.2
Service Parts / Parts Subject to Wear
Designation
Ordering number
Connecting cable with terminals for the
battery
<)
1 684 465 625
Printer paper
<)
(1 roll)
(Minimum order 5 rolls)
1 681 420 028
<)
wearing part
6.3
Changing the Printer Paper
i
The integrated printer only uses thermal paper in a
roll with the dimensions 57 mm x 25.9 mm.
1.
Unlock the printer door gently but firmly lifting up
on the release lever.
2.
Remove the empty paper roll hub.
Fig. 6:
Printer view
1 Paper Compartment
2 Paper Sensor
3 Release Lever
3.
Place a new roll of paper in the compartment.
4.
Pull the paper forward so that it extends past the
serrated edge of the paper slot.
Fig. 7:
Paper feeds from underneath the roll
5.
Close the door and make sure the lever locks securely.
6.4
Changing The Cable Assembly
1.
Identify the circled screw on the back of the tester.
2.
Remove the screw.
3.
Grasp the housing and firmly pull the cable
assembly from housing.