Preparing the Wiring
!
Caution!
Installation should only be performed by qualified service personnel in accordance with the
National Electrical Code or applicable local codes.
!
Caution!
All wires for installation applications must be routed through a grounded conduit.
Power
The recommended power cable is a 2-conductor, 14-18 gage cable, depending on the
distance.
Watts 14 AWG
(2.5
mm)
16 AWG
(1.5
mm)
18 AWG
(1.0
mm)
Camera, all models
24 VAC to AutoDome Junior
HD
17
670 ft
(204 m)
421 ft
(128 m)
265 ft
(81 m)
Heater, outdoor models only
24 VAC to Heater
25
455 ft
(139 m)
287 ft
(67 m)
180 ft
(55 m)
Table 8.1: Max. Wire Distance from Power Supply to AutoDome Junior HD
Connecting the Power
The AutoDome Junior HD is available as an indoor model only. Power to the camera in all
indoor models is supplied either via a single 24 VAC isolated power connector or via a Power
over Et (PoE+, IEEE 802.3at, class 4) connection using the existing CAT 5E Ethernet
cable.
!
Warning!
The indoor AutoDome Junior IP or HD camera models can accept power from the 24 VAC
power input or from the Ethernet input. Ensure that the camera receives power from only one
source.
Refer to Ethernet Connection (IP models), page 40, for more information about connecting
Power over Ethernet.
Notice!
Use certified / Listed Class 2 power supply transformer only.
8
8.1
8.2
AutoDome Junior HD Series
Preparing the Wiring | en
39
Bosch Security Systems, Inc.
Operation Manual
2014.11 | 6.1 | F.01U.275.803
Содержание AutoDome Junior HD VJR Series
Страница 1: ...AutoDome Junior HD Series VJR Series en Operation Manual ...
Страница 2: ......
Страница 112: ......
Страница 113: ......