![Bosch AUTODOME IP starlight 7000i NDP?7512?Z30 Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/bosch/autodome-ip-starlight-7000i-ndp-7512-z30/autodome-ip-starlight-7000i-ndp-7512-z30_installation-manual_40660057.webp)
AUTODOME IP starlight 7000i
Connection | en
57
Bosch Security Systems
Installation Manual
2021-03 | 1.2 |
i
Notice!
The heater in an outdoor AUTODOME unit cannot be powered via the Power-over-Et
(IEEE 802.3at, class 4) standard, unless the heater is connected to a High PoE Midspan 60W,
Single port (sold separately). See the Installation Manual of the Midspan for details.
Cable Type
CAT-5E or CAT 6 Ethernet
Maximum Distance
100 m (328 ft)
Bandwidth
10 Base-T/100 Base-TX
High PoE (required for pendants in outdoor applications that use
heaters)
Use the Bosch High PoE 60W midspan
(sold separately).
PoE+ (only for indoor models or indoor applications for pendant model
where heater is not required)
IEEE 802.3at, class 4 standard
Terminal Connector
RJ45, Female
i
Notice!
Consult the National Electrical Code (NEC) for cable bundling requirements and limitations.
13.4
Fiber Optic Ethernet Media Converter (Optional)
The fiber optic media converter is designed to transmit 10/100 Mbps Ethernet signals over
fiber optic cable using 10/100 Mbps Small Form-factor Pluggable (SFP) modules. The SFP
modules are available as multi-mode fiber (MMF) or single-mode fiber (SMF) models with a
single SC connector or dual-fiber with an LC connector. Refer to the VG4-SFPSCKT Fiber
Optic Media Converter Installation Guide.
Ethernet Media Converter
Data Interface
Ethernet
Data Rate
10/100 Mbps
IEEE 802.3 Compliant
Full Duplex or Half Duplex Electrical Port
Full Duplex Optical Port
Fiber Type, MMF
50/125 µm MMF. For 50/125 µm fiber, subtract 4 dB from the specified optical budget
value. Must meet or exceed fiber standard ITU-T G.651.
Fiber Type, SMF
8–10/125 µm SMF. Must meet or exceed fiber standard ITU-T G.652.
Maximum Distance
20 km (12.4 miles)
Requirement
Media converter receiver (CNFE2MC/IN) at controller end of system
Terminal Connection Duplex LC or Single SC