Stable flash
Normal Operation
Off
Power failure
DX3010
General
The AMAX panel supports DX3010 output expansion modules. Each module supports 8 fully
programmable relay outputs.
For information on the installation, refer to Module Installation, page 26.
Address Setting
Each DX3010 module connected to the AMAX panel needs its own data bus address.
Data Bus Address
Outputs
150
5-12
151*
13-20
Table 4.7: DX3010 Address Settings
DIP Switch
S1
S2
S3
S4
S5
S6
Data Bus Address
1
2
4
8
16
Mode
150
On
On
On
On
On
Off
151*
Off
On
On
On
On
Off
Table 4.8: DX3010 DIP Switch Settings
* AMAX 3000 / 3000 BE / 4000
O
1
2
3
4
5
6
D I P
N
On
Off
Figure 4.5: DX3010 DIP Switch Settings
Wiring
The following table and graphic show how to wire DX3010 to the option bus of the AMAX
panel.
Power Supply
Wire diameter of 0.8mm
Wire diameter of 1.2mm
AMAX panel
12.2m
24.4m
External power supply
305m
610m
Table 4.9: Lengths of cable for DX3010
4.4
4.4.1
4.4.2
4.4.3
18
en | Optional Modules and Peripheral Devices
AMAX panel
2015.05 | 06 | F.01U.309.277
Installation Manual
Bosch Sicherheitssysteme GmbH