Bosch 7738005548 Скачать руководство пользователя страница 1

Bosch

 

Remote Controller

For use with Bosch Split-Type Ductless Air Conditioner / Heat Pump  

User Manual

MODE

FAN

TEMP

SLEEP  

SW IN G    DI RE CT

LED         F OLLOW 

                         ME

TURBO             SE LF  

                            CLEAN

ON/ OFF

SILENCE

       FP

TIMER

  ON

TIMER

  OFF

Содержание 7738005548

Страница 1: ...osch Remote Controller For use with Bosch Split Type Ductless Air Conditioner Heat Pump User Manual MODE FAN TEMP SLEEP SW ING DIRE CT LED FOLLOW ME TURBO SELF CLEAN ON OFF SILENCE FP TIMER ON TIMER OFF ...

Страница 2: ...2 Bosch Remote Controller for Split Type Ductless Air Conditioner Heat Pump User Manual 12 2016 Bosch Thermotechnology Corp Data subject to change ...

Страница 3: ...cations 5 3 Operation of buttons 6 4 Indicators on LCD 8 5 How to use the buttons 9 5 1 Auto operation 9 5 2 Cooling Heating Fan operation 9 5 3 Dehumidifying operation 10 5 4 Timer operation 10 6 Handling the remote controller 12 6 1 Location of the remote controller 12 6 2 Using the remote controller holder optional 13 6 3 Replacing batteries 13 Distributed by Quality Heating Electrical and Air ...

Страница 4: ... indicates a hazardous situation which if not avoided will result in death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a hazardous situation which if not avoided could result in minor to moderate injury NOTICE is used to address practices not related to personal injury Important information This symbol ind...

Страница 5: ...pecifications Model Part Number RG57A6 7738005548 Rated Voltage 3 0V Alkaline AAA 2 Transmission Distance up to 25 ft Environment 23 F 140 F Table 1 MODE FAN TEMP SLEEP SWING DIRECT LED FOLLOW ME TURBO SELF CLEAN ON OFF SILENCE FP TIMER ON TIMER OFF Figure 1 Distributed by Quality Heating Electrical and Air Conditioning Full Service Furnace Water Heater and AC Repair ...

Страница 6: ...s only For more information on the SLEEP function operation please reference the unit s USER MANUAL While the unit is running in SLEEP mode it will be cancelled if the MODE FAN SPEED or ON OFF button is pressed 5 TURBO Button Press this button to Activate Disable the TURBO function TURBO function enables the unit to reach the preset temperature at cooling or heating operation in the shortest time ...

Страница 7: ...ach press will increase the auto timed setting in 60 minutes increments To cancel the auto timed program simply adjust the auto on time to 0 0 10 TIMER OFF Button Press this button to initiate the auto off time sequence Each press will increase the auto timed setting in 30 minute increments When the setting time displays 10 0 each press will increase the auto timed setting in 60 minute increments T...

Страница 8: ...ry detection Not applicable for this unit Displayed when TIMER ON time is set Displayed when TIMER OFF time is set Set temperature room temperature or time depending on current mode and function Displayed when SLEEP function is active Displayed when FOLLOW ME function is active Not applicable for this unit Not applicable for this unit Low fan speed Medium fan speed High fan speed Auto fan speed Ta...

Страница 9: ... the setting temperature on the remote controller 2 In the Auto mode you can not switch the fan speed The fan speed will be automatically controlled 3 If the Auto mode is not comfortable the desired mode can be selected manually 5 2 Cooling Heating Fan operation Ensure the unit is plugged in and power is available The OPERATION indicator on the display panel of the indoor unit will be flashing 1 Pr...

Страница 10: ...rn the unit on after the specified time 2 Push the TIMER ON button again to set desired Auto on time Each time you press the button the time increases by half an hour between 0 and 10 hours and by one hour between 10 and 24 hours 3 After setting the TIMER ON there will be a one second delay before the remote controller transmits the signal to the air conditioner Then after approximately another 2 s...

Страница 11: ...nditioner will automatically start operating at the set time Example To start the air conditioner in 6 hours 1 Press the TIMER ON button the last setting of starting operation time will show on the display area 2 Press the TIMER ON button to display 6 0H on the TIMER ON display of the remote controller 3 Wait for 3 seconds and the digital display area will show the temperature again The TIMER ON i...

Страница 12: ...he TIMER ON OFF indicator remains on and this function is activated On Stop 2 hours later after setting Set Start 10 hours later after setting Figure 11 6 Handling the remote controller 6 1 Location of the remote controller Use the remote controller within a distance of approximately25 feet from the appliance pointing it towards the receiver Reception of new information is confirmed by a beep 25ft ...

Страница 13: ...ace old batteries with new ones Receiving beep is not emitted when a signal is transmitted Indicator fades away The remote controller is powed by two dry batteries Alkaline AAA x 2 housed in the back rear part and protected by a cover 1 Remove the cover in the rear part of the remote controller 2 Remove the old batteries and insert the new batteries placing the and ends correctly 3 Re install the ...

Страница 14: ...14 Bosch Remote Controller for Split Type Ductless Air Conditioner Heat Pump User Manual 12 2016 Bosch Thermotechnology Corp Data subject to change ...

Страница 15: ...User Manual Bosch Remote Controller for Split Type Ductless Air Conditioner Heat Pump 15 Bosch Thermotechnology Corp 12 2016 Data subject to change ...

Страница 16: ...United States and Canada Bosch Thermotechnology Corp 50 Wentworth Avenue Londonderry NH 03053 Tel 866 642 3198 Fax 954 776 5529 www boschheatingandcooling com BTC 770001103 B 12 2016 ...

Отзывы: