Operation
29
Condens 7000 WP – 6721841195 (2022/01)
Settings menu
The factory settings are
highlighted
in the following table.
Meu item
Settings/adjustment range
Remark/restriction
Hydraulics
Low-loss header
Connection of temperature sensor on the low loss header
•
Off
• Low loss header not installed in the system
• NTC on device
• Low loss header installed, temperature sensor
connected to wall mounted boiler
• NTC on module
• Low loss header installed, temperature sensor
connected to heating circuit module
• NTC off
• Low loss header installed, but no temperature sensor
connected
DHW configuration
• Not installed
• 3-way valve installed
• Cyl. prim. pump inst. after low loss hdr.
• Cyl. primary pump installed
HC1 configuration
• Not installed
• Dedicated pump inst. after low loss hdr.
Pump config.
• Heating pump
Heating
Max. heat output
• 50 100%
Maximum released heat output [%].
On natural gas devices:
▶ Measure the gas rate.
▶ Compare the measurement obtained with the setting
tables (
Chapter 15.6, page 49).
▶ Correct deviations.
Standby time
• 5 …
10
… 60 min
The time interval specifies the minimum waiting time
between switching on the burner and switching it on
again.
Anticyc. temp. off
• 2 …
6
… 15 K
The difference between the current flow temperature and
the set flow temperature until the burner is switched off.
Anticycle temp. on
• -15
-6
... 2 K
The difference between the current flow temperature and
the set flow temperature until the burner is switched on.
Hot water
Max. DHW output
• 50
100
%
Maximum approved DHW output [%].
DHW circ. pump
•
Off
• On
Cycle circ. pump
• 1 x 3 minutes/h
•
2 x 3 minutes/h
• 3 x 3 minutes/h
• 4 x 3 minutes/h
• 5 x 3 minutes/h
• 6 x 3 minutes/h
• Permanent
The DHW circulation pump goes into operation 1 ... 6
times per hour for 3 minutes, or into continuous
operation.
TD-Temperature
• 60
70
… 80 °C
DHW temperature during thermal disinfection.
Start TD
• Start now?
Start thermal disinfection.
Stop TD
• Cancel now?
Cancel thermal disinfection.
Pump
Pump ctr. mode
• Energy saving
•
Heat demand
• Save energy: intelligent shutdown of heat pump for
heating systems with weather-compensated
controller. The heating pump is only switched on if
required.
• With heat demand: the flow temperature controller
switches the heating pump. If there is heat energy
demand, the heating pump starts up with the burner.
Min. output
•
10
... 100 %
Pump output at minimum heat output. Only available if
Pump range map is set to 0.