NOTE!
Rotary lobe pumps are self-priming positive displacement
pumps.
However, we recommend filling the pump with medium for suction
operation before switching it on. This shortens the priming
process and prevents dry run with increased wear.
— Suitable equipment for filling and venting may be required in
the suction and pressure lines.
— The pump should be prepared so that venting is possible
directly behind the pump, on the pressure side, during the
initial priming process.
— If the suction line is flooded with medium (e.g. gravity
feed), only the pipes need to be free and all valves open to
ensure the unrestricted transportation of pumped medium
and any air remaining in the pipe.
5.1.1
Test run with medium
Personnel:
n
Mechanics
Protective equip-
ment:
n
Occupational safety clothing, chemical
resistant
n
Safety shoes
n
Safety gloves, chemical-resistant
n
Safety goggles
This test run may only be made when
— all safety instructions have been read and adhered to
according to
Chapter 2.12 “Safety instructions for mainte-
nance and rectifying malfunctions” on page 30
— all measures detailed in the previous chapter are completed,
Chapter 4.4 “Installation” on page 62
,
— the unit is completely ready for operation, see
“Checking readiness for operation” on page 81
,
Operation
BA-Classic FL_en-US, 03.05.2018
www.boerger.de / www.boerger.com