3.1.1
Quick-release cover
The Börger MIP principle (Maintenance in Place) starts with the
quick-release cover (1). This cover enables easy access to the
interior of the casing and to all parts subject to wear in the Börger
machine. The pipes on the inlet and outlet can remain connected.
The quick-release cover can be removed after loosening the four
ring nuts (2), (see
Chapter 6.3.1 “Notes on repair work”
Chapter 6.3.2 “Opening and closing the quick-
The Börger machine can be inspected, serviced and repaired
directly at its point of installation.
The supplementary operating manual in the Appendix contains a
description of other cover types, if these types have been supplied.
3.1.2
Casing
The EL rotary lobe pump is available in three casing depths. The
performance data of your rotary lobe pump depends on this depth,
among other things:
Depths
— FL 518
— FL 776
— FL 1036
Also see
Chapter 3.3 “Technical data” on page 49
The block-type, one-piece casing is equipped as standard with an
internal casing protection plate towards the gear unit and one
towards the quick-release cover.
The casing is manufactured from high-quality gray cast iron, spher-
oidal cast iron or stainless steel.
The pump chamber can also be completely covered with optional
radial MIP
®
casing liners.
Product Description
BA-Classic FL_en-US, 03.05.2018
www.boerger.de / www.boerger.com
38
Содержание Classic FL 1036
Страница 1: ...Börger Rotary Lobe Pump Classic Operating Manual FL Series www boerger de www boerger com ...
Страница 176: ...9 3 1 Rotary lobe pump Appendix BA Classic FL_en US 03 05 2018 www boerger de www boerger com 176 ...
Страница 204: ...V belt tension 72 W Wear parts 106 Index BA Classic FL_en US 03 05 2018 www boerger de www boerger com 204 ...