background image

EN

18

Installation

www.bora.com

5.5  Cut-out dimensions

 

i

All dimensions are shown from the front edge of the front 

cover.

Worktop overhang

≥60

(≥74)

14

x

Fig. 5.7 

Worktop overhang

X

X

Please note the worktop overhang x when creating the 

worktop cut-out. Applies to flush installation and surface 

mounting.

 

i

In the case of cooktop extractor PKA3/PKA3AB 

combined with straight duct piece PKA1FEV, flush 

installation is also possible in a worktop with a depth 

≥ 650 mm.

5.5.1  Flush installation

x

A ±2

B ±2

544 ±2

≤ R5

≤ R5

≥ 74

(≥ 70)

516 ±2

≥ 700

Fig. 5.8 

Cut-out dimensions for flush installation

7 +0,5

14

10 - 40

Fig. 5.9 

Rebate dimensions for flush installation

5.4.5  Recirculation when using the cooktop 

extractor as a recirculation system

In the case of recirculation systems there must be a return flow 

aperture in the kitchen units:

X

O

> 1000 cm² (per air cleaning box) in combination with gas 

cooktop PKG3

 

i

If several extractor systems are operated in recirculation 

mode, the return flow aperture for each air cleaning box 

must be calculated accordingly. Example: 2 recirculation 

systems = 2 x (> 1000 cm²)

For recirculation, the necessary return flow aperture can be 

created using a shortened plinth. A slatted plinth with at least 

the minimum opening cross-section can also be used.

1

3

2

4

4

Fig. 5.6 

Recirculation design example (kitchen PKG3 + 

PKAS3 + air cleaning unit)

[1] 

Gas cooktop PKG3

[2] 

Cooktop extractor PKAS3 (recirculation)

[3] 

Air cleaning box (ULB1, ULB3)

[4] 

Recirculation return flow aperture (total opening cross-section 

≥ 1000 cm² per air cleaning unit)

X

X

Ensure that the return flow aperture is large enough

 

i

If the gas flame goes out or there is a high burner flame 

delay, the return flow aperture must be enlarged.

Содержание Pro PKG3

Страница 1: ...EN PKG3UMIMEN 100 www bora com Operating and installation instructions PKG3 BORA Pro gas cooktop 1 2 2 1044124 44...

Страница 2: ...1 Gas configuration menu items 27 Menu item CE GPU configuration 27 Menu item CF gas burner characteristic curves 28 Menu item Ch GPU reset 28 1 General information 4 1 1 Liability 4 1 2 Validity of...

Страница 3: ...power level 31 7 3 4 Cooktop power setting 31 7 4 Function menu 31 Calling up the function menu 31 7 4 1 Variable heat retention function 31 Activating the heat retention function 32 Increasing or re...

Страница 4: ...entially hazardous situation which can cause death or serious injury if not respected Caution Indicates a potentially hazardous situation which can cause minor injury or damage to property if not resp...

Страница 5: ...onsible for the safe use of the appliance cleaning and maintenance Improper use can lead to personal injury and damage to property 2 1 Use as intended The appliance is solely intended for preparing fo...

Страница 6: ...onductor system that has been installed in line with regulations Ensure that this basic safety precaution is met DANGER Risk of electric shock or injury from damaged surfaces The underlying electronic...

Страница 7: ...X X Make sure that technical equipment is provided to enable all of the appliance s poles to be disconnected from the mains with a contact opening width of at least 3 mm LS switch and automatic circui...

Страница 8: ...ce any items on the appliance X X Please use suitable accessories pot holders oven gloves 2 5 1 Safety instructions cooktop operation DANGER Danger of fire caused by leaving the cooktop unattended Oil...

Страница 9: ...e X X Close the gas supply and turn off the mains supply WARNING Risk of burns from hot cooktop extractor when using gas cooktops The cooktop extractor and its exposed parts in particular the cover fl...

Страница 10: ...vice team 2 8 Safety instructions disassembly and disposal i i The appliance must only be disassembled by trained specialists who are familiar with and comply with the standard national regulations an...

Страница 11: ...use protection 1 x 0 5 A Dimensions width x depth x height cooktop pan support high power burner pan support normal burner 370 x 540 x 73 mm 270 x 270 x 25 50 mm 235 x 235 x 25 50 mm Weight incl acces...

Страница 12: ...cooktop front cooking zone 5 Control knob for right cooktop rear cooking zone X X Observe all safety and warning information during operation see the Safety chapter 4 1 Control knob How it works The c...

Страница 13: ...of liquid to the boil searing steaks 8 9 Heating up water p Tab 4 2 Recommendations for power levels The specifications provided in the table are standard values Suitable cookware Cookware with this s...

Страница 14: ...ithout permission Suitable cookware is made of O O copper O O stainless steel O O aluminium O O cast iron X X Adhere to the dimensions in the table Burner position Recommended pan diameter Minimum pan...

Страница 15: ...Safety chapter X X Follow the enclosed manufacturer s information X X Please note the local regulations and connection requirements applicable to gas cooktops X X Before connecting the appliance chec...

Страница 16: ...planned the following must be taken into account O O it must be fitted in such a way that it can be removed for maintenance work O O to ensure sufficient cooktop ventilation a minimum distance of 15...

Страница 17: ...as line with an upstream stopcock i i The gas supply pipe can be connected after the gas cooktop has been installed i i The hose connection must be laid in such a way that it is not subject to deforma...

Страница 18: ...systems there must be a return flow aperture in the kitchen units O O 1000 cm per air cleaning box in combination with gas cooktop PKG3 i i If several extractor systems are operated in recirculation...

Страница 19: ...prevent tearing out the fixed front panel 5 6 1 Cooktop bore holes 40 70 50 0 5 370 80 140 1 2 3 Fig 5 13 Cooktop drilling pattern 1 Cooktop 2 Worktop 3 Fixed front panel Cooktops cooktop extractor A...

Страница 20: ...ng 1 from the rear not in the case of steel fronts X X Screw the universal nut 2 onto the knob housing 1 from the rear and tighten a little X X Align the knob housing 1 so it is level 5 6 2 Example bo...

Страница 21: ...tractor function are at the rear i i Cables of sufficient length are provided X X Tighten the universal nut 2 O O The wave spring if used must be pressed flat X X Remove the sticker 3 X X Place the kn...

Страница 22: ...n see the Safety chapter O O The plug for the power supply must be accessible following installation O O If the power supply cable has been damaged this must be replaced i i The appliance components a...

Страница 23: ...e team Power supply cable requirements and connection diagram Connection Fuse protection Minimum cross section Power supply cable 1 phase connection 1 x 16 A 1 5 mm Type H05VV F or H05VVH2 F Tab 5 4 F...

Страница 24: ...ooktop and the gas connection X X When using a leak spray for this process ensure that you wet all connections X X Shut off the gas supply if you determine that gas is escaping and ventilate the room...

Страница 25: ...ctly X X Set the gas type in the configuration menu see point 5 8 4 Configuration of gas type and gas pressure Affixing the nozzle set nameplates X X Affix the nozzle set nameplates included in the sc...

Страница 26: ...vely affected by the extractor and or the flame is not as it should be e g soot production flame blowback etc the characteristic curve must be increased as well as the ventilation in exhaust air mode...

Страница 27: ...1 29 37 mbar 5 G30 50 mbar 6 12T 20 mbar 7 20Y 28 mbar 8 G30 31 29 mbar 9 G30 31 27 5 mbar A G20 13 mbar b G25 25 3 25 mbar C G20 25 mbar Tab 6 2 Setting the gas type and gas pressure X X Select the c...

Страница 28: ...balanced adjustment of the individual power levels Characteristic curve C Characteristic curve C increases the lower power levels and should only be used in the event of a negative influence from the...

Страница 29: ...power level 0 O O Any active additional functions will be deactivated and the appliance will be switched off X X Observe all safety and warning information during operation see the Safety chapter 7 1...

Страница 30: ...tea towels or similar i i Grease splashes and other flammable food residues on the cooktop can catch fire Remove them as soon as possible X X Do not put cookware with an uneven base on the pan support...

Страница 31: ...controlled by turning the knob ring to the desired power level electronic power adjustment Fig 7 7 Setting cooking zone power levels O O The selected power level is shown in the power display on the c...

Страница 32: ...eat retention level Deactivating the heat retention function 1 2 Fig 7 12 Deactivating the heat retention function O O The cooking zone is deactivated and the control knob display shows 0 O O The resi...

Страница 33: ...timer is deactivated early and an acoustic signal is heard O O Active cooking sessions are resumed unchanged If the cooking session is to be ended X X turn the knob ring to power level 0 O O An acoust...

Страница 34: ...et power level are shown in the control knob display e g A5 Deactivating the automatic heat up function early The activated automatic heat up function will end prematurely if you X X reduce the power...

Страница 35: ...as cooktop 2 Pan support 3 Gas burner 4 Positioning aid X X Observe all safety and warning information see the Safety chapter X X Follow the enclosed manufacturer s information X X When conducting sch...

Страница 36: ...use a cooktop as a work or storage surface X X Do not push or pull cookware over the cooktop X X Always lift pots and pans X X Keep the cooktop clean X X Remove any dirt immediately X X Only use suita...

Страница 37: ...ner and degreaser in one X X Rinse the knob ring with hot water X X Clean the knob ring with a soft brush X X Rinse the knob ring well after cleaning X X Dry the knob ring carefully X X Place the dry...

Страница 38: ...s off automatically A cooking zone has been in operation too long Put the cooking zone back into operation see the Operation chapter The overheating protection has tripped see the Appliance descriptio...

Страница 39: ...ly These can damage human health or the environment if disposed of improperly or incorrectly handled X X Never put your old appliance in domestic waste X X Take the old appliance to a regional collect...

Страница 40: ...ress of condensation damage caused by the elements such as a lightning strike O O Damage caused by repairs or attempts to repair not made by BORA or persons authorised by BORA O O Damage to the glass...

Страница 41: ...EN 41 Notes www bora com 12 Notes...

Страница 42: ...EN 42 Notes www bora com...

Страница 43: ...EN 43 Notes www bora com...

Страница 44: ...our apologies in this eventuality An updated version can be requested from the BORA Service Team Subject to printing errors and mistakes BORA Vertriebs GmbH Co KG All rights reserved AU NZ BORA APAC P...

Отзывы: