![bora PKT3UMIMEN-102 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/bora/pkt3umimen-102/pkt3umimen-102_operating-and-installation-instructions_2788221018.webp)
EN
18
Installation
www.bora.com
5.8.1 Connecting the control knobs
i
Control knobs must only be connected to the ports
provided on the appliance.
1
Fig. 5.19
Back of control knob with port
[1]
Port on the back of the control knob
X
Connect the control knobs to the appliances.
Connecting the control knobs to the cooktop
i
In the normal set-up the ports are on the back of the
Tepan stainless steel grill PKT3.
i
In the case of the built-in version of the PKT3 installed
rotated by 180°, excess cable must be reeled up in
meander form and secured with cable ties.
i
According to the default settings, the left control knob
operates the front cooking zone (zone 1) and the right
control knob operates the rear cooking zone (zone 2).
3
2
1
ZONE1 INTERF. COM1 ZONE2
Fig. 5.20
Control knob port at the rear of the cooktop
[1]
Front cooking zone control knob port (zone 1)
[2]
Extractor electronics interface port
[3]
Rear cooking zone control knob port (zone 2)
Securing the Tepan stainless steel grill PKT3
3
2
21
4
Fig. 5.18
Mounting brackets
[1]
Mounting bracket
[2]
Washer
[3]
Screw
[4]
Screw (60 mm)
X
Secure the appliance using the mounting brackets [1].
X
Tighten the mounting brackets with the screws [3] and [4]
using the washer [2] with max. 2 Nm.
X
Verify that the alignment is correct.
5.7.2 Installation rotated by 180° (alternative
installation variation)
Installation rotated by 180°
X
Rotate the cooktop 180°.
X
For the installation, proceed as described above.
X
Change the installation direction in the configuration menu
(see “Configuration menu”).
i
If installation is rotated by 180°, then on the Tepan
stainless steel grill PKT3 the ports for the control knobs
and the automatic extractor function are at the front.
i
Cables of sufficient length are provided.
5.8 Establishing communication and
power connection
X
Observe all safety and warning information (see „2 Safety“).
O
The plug for the mains supply cable must be accessible
following installation.
O
If the mains supply cable has been damaged this must be
replaced.
i
The appliance components are linked by the ribbon cable
provided.