bora Classic CKCB Скачать руководство пользователя страница 8

EN

8

Safety

www.bora.com

2.2.2  Safety instructions – cooktop 

extractor installation

 DANGER!

Risk of poisoning caused by 

combustion gases!

When the cooktop extractor is used 

in exhaust mode, it draws in air from 

the room it is installed in and from 

neighbouring rooms. Without sufficient 

air, there will be a drop in air pressure. 

Toxic gases could be drawn out of the 

chimney or extraction ducting on a 

fireplace that depends on the room air 

and back into the room.

X

X

Make sure that there is always a 

sufficient air supply.

X

X

Only use reliable, tried-and-tested 

switching devices, (e.g. window 

contact switch, low pressure 

warning device) and have them 

approved by a qualified expert 

(certified chimney sweep).

 DANGER!

Risk of electric shock!

The control unit can contain residual 

charge and cause an electric shock.

X

X

Do not touch exposed contacts on 

the control unit.

 DANGER!

Risk of electric shock!

Incorrect stripping of the connection 

cable to external switching devices 

results in a risk of electric shock.

X

X

Ensure that the connection cable is 

secured with the strain relief clamp 

within the universal control unit.

X

X

Ensure that the stated stripping 

lengths are adhered to.

 DANGER!

Risk of electric shock and damage to 

property!

A damaged operating unit can lead to a 

short circuit.

X

X

Do not operate any appliance with a 

damaged operating unit.

X

X

Inform a BORA Service technician 

and have the operating unit 

replaced.

Special safety information for exhaust air 

systems:

X

X

Observe the duct length in the case of 

straight ducting between the fan and wall 

sleeve.

Q

Q

It is necessary to plan a duct length of at least 

90 cm between the fan exhaust opening and 

the wall sleeve exhaust opening.

2.3  Safety instructions – 

disassembly and disposal

The appliance must only be disassembled by 

trained specialists who are familiar with and 

comply with the standard national regulations 

and supplementary regulations of the local utility 

companies. 
Work on electrical components must only be 

conducted by trained electrical personnel.

 

 DANGER!

Risk of electric shock!

Incorrectly disconnecting the appliance 

from the mains results in a risk of 

electric shock.

X

X

Securely disconnect the appliance 

from the mains using LS switches, 

fuses, automatic circuit breakers or 

contactors.

X

X

Use an authorised measuring device 

to ensure that there is no power to 

the appliance.

X

X

Do not touch exposed contacts on 

the electronic unit as they can 

contain residual charge.

Special safety information for gas cooktops

Work on the gas connection may only be carried 

out by an authorised gas fitter in accordance 

with applicable legal regulations. Comply with 

the local regulations of the utility companies.

Содержание Classic CKCB

Страница 1: ...EN C2XIMEN 004 www bora com BORA Classic 2 0 system installation instructions Cooktop extractor and cooktops...

Страница 2: ...ontents are prohibited unless expressly authorised Great care was taken when devising these operating and installation instructions However it may be the case that later technical changes or adaptatio...

Страница 3: ...on dimensions 23 4 7 Installation options 24 4 8 Assembling the extraction system 25 4 8 1 Assembling cooktop extractor CKA2 25 4 9 Installing the cooktop extractor 25 4 9 1 Fitting and positioning th...

Страница 4: ...regulations and laws All safety and warning information as well as the handling instructions in the operating and installation instructions must be observed 1 2 Validity INFO These instructions descr...

Страница 5: ...asised with symbols and signal words Safety and warning instructions are structured as follows WARNING SYMBOL AND SIGNAL WORD Type and source of danger Results of non compliance X X Measures to minimi...

Страница 6: ...use the appliance until installation is complete This is the only way to ensure safe operation X X Make sure contact with hot cooking surfaces is not possible X X Do not place any objects on the oper...

Страница 7: ...iately DANGER Risk of asphyxiation Packaging components e g film polystyrene can be life threatening for children X X Store all packaging components out of reach of children X X Dispose of the packagi...

Страница 8: ...erating unit can lead to a short circuit X X Do not operate any appliance with a damaged operating unit X X Inform a BORA Service technician and have the operating unit replaced Special safety informa...

Страница 9: ...burners on the cooktop is reduced The appliance is solely intended for preparing food in private households This appliance is not intended for Q Q outdoor use Q Q installation in vehicles Q Q heating...

Страница 10: ...x 190 mm Weight incl accessories packaging 7 5 kg Surface material SSG glass 1 4301 stainless steel and plastic Cooktop extractor Power levels 1 5 P Connection on the exhaust side BORA Ecotube Tab 3 1...

Страница 11: ...Fuse protection 1 x 16 A Dimensions width x depth x height 327 x 515 x 58 mm Weight incl accessories packaging 7 9 kg Cooktop Power levels 1 9 P Warming levels 3 Front cooking zone zone 1 power settin...

Страница 12: ...Power consumption 3 68 kW Fuse protection 1 x 16 A Dimensions width x depth x height 327 x 515 x 58 mm Weight incl accessories packaging 7 6 kg Cooktop Power levels 1 9 P Warming levels 3 Front cooki...

Страница 13: ...90 450 32 5 Fig 3 13 CKIW device dimensions side view 3 4 CKIW Parameter Value Supply voltage 220 240 V Frequency 50 60 Hz Power consumption 3 0 kW Fuse protection 1 x 16 A Dimensions width x depth x...

Страница 14: ...consumption 3 68 kW Fuse protection 1 x 16 A Dimensions width x depth x height 327 x 515 x 75 mm Weight incl accessories packaging 7 2 kg Cooktop Power levels 1 9 P 2 ring additional switching Warming...

Страница 15: ...ion 1 x 16 A Dimensions width x depth x height 327 x 515 x 75 mm Weight incl accessories packaging 7 4 kg Cooktop Power levels 1 9 2 ring connection roaster cooking zone connection Warming levels 3 Fr...

Страница 16: ...s width x depth x height cooktop pan support high power burner pan support normal burner 327 x 515 x 73 mm 270 x 270 x 25 50 mm 235 x 235 x 25 50 mm Weight incl accessories packaging 11 5 kg Cooktop P...

Страница 17: ...g Cooktop Temperature control power levels 150 230 C 250 C 1 9 P Warming levels 3 Front cooking zone zone 1 250 x 220 mm 1750 W Rear cooking zone zone 2 250 x 220 mm 1750 W Temperature control range 7...

Страница 18: ...ir in the room INFO The state and regional laws and regulations must be observed with regard to the exhaust duct design INFO A sufficient air supply must be ensured Fireplaces that depend on the air i...

Страница 19: ...n units of the base cabinet must be shortened depending on the installation situation X X Do not under any circumstances install parts which are damaged X X Dispose of transport packaging in the prope...

Страница 20: ...INFO The stopcock and gas supply pipe connections must be accessible INFO It must be possible to inspect the entire length of the hose line once installed INFO Only compatible connection pieces are t...

Страница 21: ...7 Worktop overhang X X Please note the worktop overhang x when creating the worktop cut out Applies to flush installation and surface mounting INFO The hose line must not come into contact with hot s...

Страница 22: ...25 Tab 4 4 Cut out dimensions of the appliance combinations in the case of surface mounting 4 5 1 Flush installation x A 2 B 2 519 2 R 5 R 5 50 50 495 2 600 Fig 4 8 Cut out dimensions for flush instal...

Страница 23: ...unit depth of 600 mm min 100 max 580 495 min 700 min 50 max 440 530 219 151 min 900 190 290 120 Fig 4 15 Appliance installation dimensions with shallow silencer USDF in case of a unit depth of 700 mm...

Страница 24: ...on options It is necessary to decide which installation option is to be implemented prior to installation X X Please ensure prior to installation that you have made the correct preparations for the co...

Страница 25: ...the adapter panel has been fitted correctly by looking at the arrow markings on the panel and the base module These must be correctly aligned Assembling the individual components 3 2 1 Fig 4 21 Assemb...

Страница 26: ...actor free of load and with the power supply switched off INFO Please bear in mind that for correct installation the slide in units of the base cabinet can be shortened depending on the installation s...

Страница 27: ...ction you can vary the height at which the sealing tape is attached to the plinth fan inlet nozzle INFO If another Universal fan module is to be used this must also be prepared as described here with...

Страница 28: ...Ensure that a minimum clearance of 3 m is maintained between the fan units X X Use only BORA Universal fans If additional fans are installed at a later date X X When installing additional fans at a l...

Страница 29: ...actor 1 Tensioning screw 2 Fixing bracket X X Turn the four fixing brackets 2 under the worktop Q Q The fixing brackets are secured against slipping by a ratchet mechanism X X Tighten the tensioning s...

Страница 30: ...ed Contact Function Connection Home In Cooktop extractor on off connection for external switch contact contact closed cooktop extractor on 24V DC 100 mA Home Out Electrically isolated contact for cont...

Страница 31: ...ase adhere to the maximum stripping length of the outer sheath of 25 mm on the insulated wire 2 Installing the external switch device Depending on the type of switch device connect the connection cabl...

Страница 32: ...nection diagram for cooktop extractor CKA2 1 Cooktop mains cable 2 Power supply per cooktop 3 CAT 5e communication cable 4 CAT 5e cooktop communication cable 5 USB interface 6 Control unit mains cable...

Страница 33: ...cable and mains cable it does not matter if you use socket 1 or 2 on the control unit 4 13 5 Positioning the control unit INFO The control unit must be placed inside the kitchen unit INFO Position th...

Страница 34: ...appliance 4 14 2 Gas connection This gas cooking appliance corresponds to device class 3 It is equipped with a flexible connection tube The gas hose must meet the requirements of EN14800 Q Q The insta...

Страница 35: ...o the appliance is disconnected Changing the gas burner nozzle in the gas burner INFO The nozzles regulate the maximum gas throughflow for each burner and gas type pressure INFO The gas cooktop is set...

Страница 36: ...on on the gas configuration menu can be seen in the operating instructions X X Enter the settings in the gas configuration menu see operating instructions Extended menu chapter 4 15 Initial operation...

Страница 37: ...lts when using gas cooktop CKG for the first time When operating for the first time or after a prolonged period without use or when the liquid gas bottles have been changed faults are possible Q Q The...

Страница 38: ...r Environmentally friendly disposal 5 3 Environmentally friendly disposal Disposal of transport packaging INFO The packaging protects the device from damage in transport The packaging materials have b...

Страница 39: ......

Страница 40: ...dorf Austria Tel 43 0 5373 62250 0 Fax 43 0 5373 62250 90 mail bora com www bora com Europe BORA Holding GmbH Innstra e 1 6342 Niederndorf Austria Tel 43 0 5373 62250 0 Fax 43 0 5373 62250 90 mail bor...

Отзывы: