![bora Classic CKCB Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/bora/classic-ckcb/classic-ckcb_installation-instructions-manual_2788242037.webp)
EN
37
Installation
www.bora.com
If all cooktops have been recognised correctly:
X
X
Carry out the basic configuration.
4.15.1 Function test
X
X
Carry out a thorough function test on all devices.
X
X
In the event of error messages, see the
“Troubleshooting” chapter in the operating
instructions.
Function test on gas cooktop CKG
X
X
Switch the cooking zone on.
The electronic gas regulator will calibrate itself (humming
noises) and then the gas flame will automatically ignite in
the selected cooking zone.
The gas flame will burn steadily and evenly.
Using the gas cooktop together with the
cooktop extractor for the first time
X
X
Switch the cooktop extractor to the maximum power
level.
X
X
Switch all cooking zones to the minimum power level.
The electronic gas regulator will calibrate itself (humming
noises) and then the gas flame will automatically ignite in
the selected cooking zone.
The gas flame will burn steadily and evenly (no reignition).
The gas flame will be slightly affected by the cooktop
extractor (airflow) – this is normal.
INFO
If the gas flame goes out, is excessively affected
by the extractor and/or the flame is not as it
should be (e.g. soot production, flame blowback,
etc.), the characteristic curve must be increased,
as well as the ventilation in exhaust air mode,
if necessary, or the return flow aperture in
recirculation mode.
Faults when using gas cooktop CKG for the
first time
When operating for the first time or after a prolonged
period without use or when the liquid gas bottles have
been changed, faults are possible:
Q
Q
The burner does not ignite.
Q
Q
There may be air in the gas pipe.
X
X
Repeat the ignition process.
Q
Q
The burner does not ignite and the cooktop does not
react.
Q
Q
The electronic gas regulator must be recalibrated.
X
X
Using the gas configuration menu,
reset the gas
regulator.
4.16 Sealing the devices
1
Fig. 4.48 Silicone sealant for flush installation
[1]
black, heat-resistant silicone sealant
1
Fig. 4.49 Silicone sealant for surface mounting
[1]
black, heat-resistant silicone sealant
X
X
Once all of the installation work and initial operation is
complete, seal the devices all around with black, heat-
resistant silicone sealant (also between the cooktop
extractor and cooktop) [1].
X
X
Make sure that no silicone sealant gets under the
cooktop.
4.17 Handover to user
Once installation is complete:
X
X
Explain the main functions to the user.
X
X
Explain all safety-related aspects of operation and
handling to the user.
X
X
Affix the identification plates provided to the
penultimate page in the operating instructions (see
Operating instructions, Identification plates chapter).
If a CKG gas cooktop is installed:
X
X
also affix the nozzle set nameplate to the inside of
the back cover of the CKG gas cooktop operating
instructions.
X
X
Provide the user with the accessories and operating
and installation instructions, which are to be kept in a
safe place.
Содержание Classic CKCB