Duotour DTAC
Boon Edam B.V. P.O.Box 40, 1135 ZG Edam Holland.
2016/03/09
3,6
4,2
4,8
5,4
11
11
10
10
40 sec.
+
1x
Locking devices
1 Interated electromagnetic lock
(fail-safe).
2 Electromechanical lock
(bi-stable).*
3 Mechanical lock.*
Maintenance
Check daily :
•
Emergency-, safety devices and general operation of the door.
•
Presence of loose parts, sharp edges or broken glass.
•
Safety and contrasting stickers are applied.
•
Lighting; to provide a proper level of illumination inside the door.
•
Floor condition; avoid slipping or tripping hazards and excessive dirt inside the door.
Weekly :
•
Clean the anodised, powder coated and/or stainless steel surfaces with a wet cloth.
Monthly :
•
Clean the anodised, powder coated and/or stainless steel surfaces with a wet cloth
and a non-aggressive soap. Stainless steel surfaces need to be cleaned
according the instruction below, Vacuum clean all the brushes.
Yearly :
•
The door needs a major maintenance check once a year.
This has to be done by Boon Edam or an approved agent. This applies as well for repairs.
Note :
•
Make sure maintenance is properly recorded in the Logbook inside the door.
Caution !
Don’t use water near the drive-units or control boxes.
Warning !
Switch OFF the power supply of the door during maintenance or other work.
Cleaning Instruction
Sensors :
•
Remove dirt and dust with a wet cloth and dry with a clean soft cloth.
Avoid scratching!!
Stainless steel parts:
•
Use sponge to wipe the parts clean and dry with a clean cloth.
•
Apply an even spray Inno-x on the surface to be treated or spray it on a clean,
dry and soft cloth and apply. Rub off with a clean, dry and soft cloth.
Operating limitation
Do not use the door when the wind force at the entrance exceeds the Beaufort
value as indicated in the table below. To prevent damage or injuries make sure
the door is switched off and locked.
Diameter
[meter]
I n s t r u c t i o n c a r d
D u o t o u r D T A C
Safety- and users instructions
Control panel
Touch screen display
Locking devices
Maintenance
Cleaning instruction
Operating limitation
Explanation of the symbols
Outside
Inside
Doorset stops.
Doorset rotates on normal speed
.
Doorset rotates on slow speed.
Doorset rotates into restposition.
Doorset does not rotate.
Doorwings free to move.
Doorset rotates slow
during 40 seconds.
Uninteruptable Power Supply
activated (UPS).
After 30 min. one
programmable last action.
No power supply.
Emergency pushbutton.
Disabled pushbutton.
Acoustic signal.
Optional / CE Plus.
Extra country specific.
Warning :
•
Any children or minors using the product must be supervised by a responsible adult.
•
This product should not be considered as a playground. Do not let children play inside or near the door.
•
Running or dashing into a closing door are prohibited.
•
In case of broken glass do not use the door. Take all necessary precautions
to avoid people coming into contact with sharp edges of the broken glass.
Version :
Edition :
DTAC-INS-UK