background image

ON

OFF

Enter

1100

6.61

mA

V

1

2

1

2

Turning Intelliswitch ON and OFF

To Switch Intelliswitch ON 

(after battery con

-

nection is made) 

PRESS AND HOLD 

the 

GREEN 

“ON/OFF”

 

button.  Intelliswitch will start to 

FLASH “

TURN ON

”. While flashing press the 

RED 

“ENTER”

 button once and Intelliswitch will 

switch both batteries on supplying power.

TURN

ON

TURN

OFF

To Switch Intelliswitch OFF - PRESS AND HOLD 

the 

GREEN “ON/OFF”

 

button.  

Intelliswitch will start to FLASH “

TURN OFF

”. 

While flashing press the 

RED “ENTER”

 button 

and Intelliswitch will switch both batteries off 
and removing power to the receiver(s).

Intelliswitch is supplied with 2 x fail-safe switches. As long as 
power is supplied to Intelliswitch it will hold the state of the 
switch.  Intelliswitch also comes with additional protection 
circuitry to avoid an accidental ON or OFF state. 

6

Содержание BRC-IS1

Страница 1: ...BRC IS1 Intelliswitch Booma RC 1 www boomarc com...

Страница 2: ...digital switching circuits Fail Safe Switching of both batteries Back lit LCD for easy daylight reading Voltage Monitoring of each battery BRC IS1A and BRC IS1V version Battery Consumption of each bat...

Страница 3: ...be desirable if you are experienced with modeling or Robot ics however you do this at your own risk It is recommended that Intelliswitch is used in conjunction with a Booma RC Dual Battery isolator fo...

Страница 4: ...rvos Left Side Servos Right Side Matched Battery 1 Matched Battery 2 Intelliswitch Circuit 1 Intelliswitch Circuit 2 Dual Battery Isolator Single Receiver or CyBus servo power distribution Typical Con...

Страница 5: ...l liswitch is asking whether you want to reset the battery capacity usage meters which of course you want to after each battery recharge This functionality allows you to monitor how much capacity has...

Страница 6: ...pplying power TURN ON TURN OFF To Switch Intelliswitch OFF PRESS AND HOLD the GREEN ON OFF button Intelliswitch will start to FLASH TURN OFF While flashing press the RED ENTER button and Intelliswitch...

Страница 7: ...nect Intelliswitch from the batteries if storing your model for a long period WHAT HAPPENS IN SLEEP MODE To conserver power Intelliswitch turns off all unnecessary circuits blanks the display and turn...

Страница 8: ...Template Cutout for Intelliswitch 8 22 8 mm 0 9 in 56 mm 2 2 in Will not be to scale unless printed 8 up to a page...

Страница 9: ...tate Intelliswitch displays several pages of information Pressing ENTER moves one page to the right Pressing ON OFF moves one page to the left Paging Through the Displays 9 Page 1 In Switched Off Cond...

Страница 10: ...nds This is the time the model is switched on Page 4 Switched On Off Condition is a built in flight log which shows the number of flights on the airframe Page 5 Switched On Off Condition shows the tem...

Страница 11: ...s Battery selection IMPORTANT DO NOT MIX BATTERY CHEMISTRY WHEN USING INTELLISWITCH ALWAYS USE BATTERIES OF THE SAME CHEMIS TRY AND CAPACITY Intelliswitch comes pre calibrated to monitor voltage level...

Страница 12: ...Template Cutout for Intelliswitch 12 22 8 mm 0 9 in 56 mm 2 2 in Will not be to scale unless printed 8 up to a page...

Страница 13: ...aim of metering battery capacity with your Intelliswitch is to get to know the characteristics of your bat teries so you can monitor the health of your battery packs Connecting the outputs of Intellis...

Страница 14: ...may end in disaster Intelliswitch meters consumption conservatively but YOU SHOULD ALWAYS RECHARGE AT 30 to 35 OF BATTERY CAPACITY Battery Recharge Guide Battery capacity 1200mA recharge at 800mA usag...

Страница 15: ...7 2 volt servos then we recom mend using Intelliswitch with Lion nominal 8 2v or Lipo batteries nominal 8 4v These batteries will in most cases require a voltage regulator like the Booma RC Intelli R...

Страница 16: ...A current draw in power down mode Length 56 mm x width 23 mm x Depth 25 mm 12 Month Replacement Warranty Booma RC will replace this product within 12 months if found to be defective in material and or...

Отзывы: